Applied Physics Letters

Low-noise parametric amplification at 35 GHz in a single Josephson tunnel junction

J. Mygind, N. F. Pedersen, O. H. Soerensen, Bjørn Dueholm, Mogens T. Levinsen

Published Jul 1, 1979• 25 citations
Publisher

Abstract

Parametric amplification at 35 GHz has been obtained using a single Josephson tunnel junction as the active element. The amplifier was operated in the singly quasidegenerate mode with a pump frequency at 70 GHz. The noise temperature was measured and found correlated with the gain. At the highest gain achieved, 11.6 dB, the noise temperature was 400 K. The noise temperature was reduced considerably by decreasing the gain. At 8 and 4 dB we found 165±25 K and 50±30 K, respectively.

DOI
10.1063/1.90906

Related papers

X-band singly degenerate parametric amplification in a Josephson tunnel junction

J. Mygind, N. F. Pedersen, O. H. Soerensen

Preliminary measurements on a (quasi-) degenerate parametric amplifier using a single Josephson tunnel junction as the active element is reported. The pump frequency is at 18 GHz and the signal and idler frequencies are both at about 9 GHz. A power gain of 16 dB in a 4-MHz 3-dB bandwidth is achieved at the top of the cryostat.

Applied Physics Letters•Jan 1, 1978•26 citations

Low-noise self-pumped Josephson tunnel junction amplifier

Nils P. Calander, T. Claeson, S. Rudner

We have studied the parametric amplification properties of an internally pumped Josephson tunnel junction, where the shunt contained resistive and inductive components. The amplification was, in this case, limited by circuit component values to less than 8 dB at 10 GHz, but it was very stable against variations in bias conditions. The amplifier gain-bandwidth product was large and the noise level very low. We estimated the noise temperature to be less than 50 K, which should make the device attractive for mm-wave amplification.

Applied Physics Letters•Oct 15, 1981•10 citations

Arrays of Josephson tunnel junctions as parametric amplifiers

S. Wahlsten, S. Rudner, T. Claeson

Arrays of 10 or 40 series-connected small densely packed Josephson tunnel junctions were successfully operated as parametric amplifiers at 10 GHz. Between 50 and 90% of the junctions in an array were observed to work coherently in the amplification process. Signal gain exceeding 24 dB was achieved with a pump power as low as −50 to −70 dBm. A power width (i.e., the range of the pump power for a gain within 3 dB of the peak gain) of 0.25 dB and a bandwidth of 15 MHz were measured for 20-dB gain. The power width was in accordance with theory but the bandwidth was reduced, probably due to noise saturation effects. The latter effects can be reduced by lowering the input noise temperature or by including an external band limitation. The noise temperature was also increased by saturation; however, with an external bandwidth of 60 MHz, a noise temperature of 30±20 K was measured. The application of a magnetic field has proved extremely useful as a means of tuning the amplifiers to stable high-gain operating points. This tuning was also utilized in evaluating the amplifier parameters, and the theory by Feldman, Parrish, and Chiao has been verified. The upper frequency limit for a lead tunnel junction amplifier ought to be well above 300 GHz.

Journal of Applied Physics•Jul 1, 1978•61 citations

Parametric amplification in arrays of Josephson tunnel junctions

S. Wahlsten, S. Rudner, T. Claeson

Arrays of 30 series-connected unbiased small Josephson tunnel junctions give parametric amplification at 10 GHz. A pump power of 10−8 W was required and gains of up to 24 dB were achieved. The gain was constant for a large range of signal power, up to a signal output power of 10 dB below the pump power. A maximum brightness temperature of 1.7×106 K, in a bandwidth of 12 MHz, was deduced from variations of the gain with input noise level.

Applied Physics Letters•Mar 15, 1977•29 citations

Shunted Josephson tunnel junctions: High-frequency, self-pumped low noise amplifiers

Nils P. Calander, T. Claeson, S. Rudner

The high-frequency amplification properties of transformer coupled, resistively shunted Josephson tunnel junctions have been investigated. The importance of the shunt loop inductance is stressed. It allows a high cutoff frequency, of significance for good high-frequency performance. The self-pumped parametric amplifier showed none of the excessive noise rise, which has hitherto plagued the development of externally pumped Josephson junction amplifiers. Around 10 GHz, we estimated a noise temperature less than 30 K for an amplifier pumped by a Josephson oscillation with a frequency well above twice the signal frequency. The corresponding gain of 5 dB may be increased in a better impedance matched circuit. The gain was very stable against variations in the bias conditions. A gain-bandwidth product as high as 0.3 was registered. The experimental results agreed well with the established theory for self-pumped parametric Josephson amplifiers. It should be possible to extend the low noise amplification by this device to mm wave frequencies. A relaxation oscillation occurred at a subharmonic of the Josephson frequency when the shunt loop inductance became large. The amplification in this mode followed closely the predictions of a simple model, where the signal modulated the switching of the sawtooth-like (relatively low frequency) relaxation current. Gains of about 15 dB were measured around 10 GHz, but the amplification was sensitive to bias conditions and noisy in this case where the relaxation frequency fell well below the signal frequency. Much improved properties were registered when the inductance was decreased so that the relaxation frequency approached the Josephson frequency and exceeded twice the signal frequency. The behavior then resembled that of a Josephson mode parametric amplifier, but the high content of harmonics of a relaxation oscillation meant that the amplifier became noisier due to converted noise from the many idler frequencies.

Journal of Applied Physics•Jul 1, 1982•26 citations

Parametric amplification and oscillation at 36 GHz using a point-contact Josephson junction

Y. Taur, P. L. Richards

We have observed doubly degenerate parametric amplification and oscillation at 36 GHz from a single point-contact Josephson junction. The experimental results agree qualitatively with theoretical calculations based on the resistively shunted junction model. The estimated noise temperature of an amplifier with 11 dB net gain is consistent with zero, but has an upper limit of 50 K. Attempts to observe parametric amplification in the singly degenerate mode with a pump frequency of 72 GHz were not successful.

Journal of Applied Physics•Mar 1, 1977•44 citations
Parametric amplification at 35 GHz has been obtained using a single Josephson tunnel junction as the active element. The amplifier was operated in the singly quasidegenerate mode with a pump frequency at 70 GHz. The noise temperature was measured and found correlated with the gain. At the highest gain achieved, 11.6 dB, the noise temperature was 400 K. The noise temperature was reduced considerably by decreasing the gain. At 8 and 4 dB we found 165±25 K and 50±30 K, respectively.
We have studied the parametric amplification properties of an internally pumped Josephson tunnel junction, where the shunt contained resistive and inductive components. The amplification was, in this case, limited by circuit component values to less than 8 dB at 10 GHz, but it was very stable against variations in bias conditions. The amplifier gain-bandwidth product was large and the noise level very low. We estimated the noise temperature to be less than 50 K, which should make the device attractive for mm-wave amplification.
Arrays of 10 or 40 series-connected small densely packed Josephson tunnel junctions were successfully operated as parametric amplifiers at 10 GHz. Between 50 and 90% of the junctions in an array were observed to work coherently in the amplification process. Signal gain exceeding 24 dB was achieved with a pump power as low as −50 to −70 dBm. A power width (i.e., the range of the pump power for a gain within 3 dB of the peak gain) of 0.25 dB and a bandwidth of 15 MHz were measured for 20-dB gain. The power width was in accordance with theory but the bandwidth was reduced, probably due to noise saturation effects. The latter effects can be reduced by lowering the input noise temperature or by including an external band limitation. The noise temperature was also increased by saturation; however, with an external bandwidth of 60 MHz, a noise temperature of 30±20 K was measured. The application of a magnetic field has proved extremely useful as a means of tuning the amplifiers to stable high-gain operating points. This tuning was also utilized in evaluating the amplifier parameters, and the theory by Feldman, Parrish, and Chiao has been verified. The upper frequency limit for a lead tunnel junction amplifier ought to be well above 300 GHz.
The high-frequency amplification properties of transformer coupled, resistively shunted Josephson tunnel junctions have been investigated. The importance of the shunt loop inductance is stressed. It allows a high cutoff frequency, of significance for good high-frequency performance. The self-pumped parametric amplifier showed none of the excessive noise rise, which has hitherto plagued the development of externally pumped Josephson junction amplifiers. Around 10 GHz, we estimated a noise temperature less than 30 K for an amplifier pumped by a Josephson oscillation with a frequency well above twice the signal frequency. The corresponding gain of 5 dB may be increased in a better impedance matched circuit. The gain was very stable against variations in the bias conditions. A gain-bandwidth product as high as 0.3 was registered. The experimental results agreed well with the established theory for self-pumped parametric Josephson amplifiers. It should be possible to extend the low noise amplification by this device to mm wave frequencies. A relaxation oscillation occurred at a subharmonic of the Josephson frequency when the shunt loop inductance became large. The amplification in this mode followed closely the predictions of a simple model, where the signal modulated the switching of the sawtooth-like (relatively low frequency) relaxation current. Gains of about 15 dB were measured around 10 GHz, but the amplification was sensitive to bias conditions and noisy in this case where the relaxation frequency fell well below the signal frequency. Much improved properties were registered when the inductance was decreased so that the relaxation frequency approached the Josephson frequency and exceeded twice the signal frequency. The behavior then resembled that of a Josephson mode parametric amplifier, but the high content of harmonics of a relaxation oscillation meant that the amplifier became noisier due to converted noise from the many idler frequencies.
We have observed doubly degenerate parametric amplification and oscillation at 36 GHz from a single point-contact Josephson junction. The experimental results agree qualitatively with theoretical calculations based on the resistively shunted junction model. The estimated noise temperature of an amplifier with 11 dB net gain is consistent with zero, but has an upper limit of 50 K. Attempts to observe parametric amplification in the singly degenerate mode with a pump frequency of 72 GHz were not successful.