Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chemical Physics Letters

Saturation effects in time-resolved and frequency-resolved resonance Raman and resonance fluorescence induced by realistic coherent pulses

A D Wilson, Harry Friedmann, V. Ahiman

Published Nov 1, 1976• 14 citations
Publisher
DOI
10.1016/0009-2614(76)80618-5

Related papers

Theory of time- and frequency-resolved resonance Raman and resonance fluorescence induced by realistic coherent pulses of arbitrary strength

A D Wilson, Harry Friedmann

Chemical Physics•Jul 1, 1977•20 citations

Fluorescence induced by coherent optical pulses

H.P. Grieneisen, Norman A. Kurnit, A. Szöke

Optics Communications•Jun 1, 1971•15 citations

A Theoretical Distinction Between Time-Resolved Resonance Raman and Resonance Fluorescence

Jing Lu, Si-de Du, Kangnian Fan +1 more

Based on the time-dependent theory, an analysis of the distinction between resonance Raman (RR) and resonance fluorescence (RF) with pulse excitation was presented. The real population of the intermediate state gives two optical components-the independent time evolution of intermediate ket and bra states generates RR while RF originates from the phase coherent between ket and bra states. In cw limit, the transition probability of spontaneous emission with pulse excitation can be reduced to the classical theory.

Chinese Physics Letters•Apr 1, 2000•0 citations

Coherence effects in ordinary Raman scattering in the presence of two-photon resonance

A. D. Wilson‐Gordon, Harry Friedmann

In the presence of coherent saturated near-resonant two-photon excitation, the ordinary Raman scattering line is replaced by a dynamic Stark shifted or Stark split doublet, and Rabi nutations appear in the time-resolved ordinary Raman spectrum. The relative intensity of the peaks of the doublet depends on the shape and on the average frequency of the exciting pulse. Striking new features arise from the interfering contributions of the upper and lower states of the two-photon transition to the Raman scattering process. The theory is applied to Raman scattering in atomic Na in the presence of the 3 2 S 1 2/(F=1, M F =1) to 4 2 D 3 2,5/2/(F=3,M F =3) two-photon resonances.

Journal of Physics B Atomic and Molecular Physics•Apr 14, 1979•4 citations

Stimulated and coherent Raman spectroscopy with 0? pulses

Suman S. Dhayal, Yuri V. Rostovtsev

Bulletin of the American Physical Society•Mar 5, 2015•0 citations

Two-Color Suppression of Stimulated Raman Scattering

Thomas Würthwein, Niels Irwin, Carsten Fallnich

Summary form only given. Sub-diffraction limited imaging schemes have become widely used in fluorescence microscopy [1]. Howaever, the need for labeling with fluorescent dyes remains a major downside of fluorescence microscopy. The size, availability, toxicity as well as photo-bleaching of the used dyes can complicate measurements [2]. In contrast, Raman imaging is inherently label-free. Unfortunately, the super-resolution schemes used in fluorescence microscopy are currently not transferable to Raman microscopy. This paper presents the development of a scheme for the suppression of coherent Raman scattering through the depletion of probe photons, inspired by the work of M. Cho et al. [3, 4], who showed the suppression of coherent Raman scattering using laser pulses at three different wavelengths and two Raman resonances. In our case, probe depletion is achieved through saturated stimulated Raman scattering in a three-beam setup with only two colors involved. Fig. 1 (a) describes the working principle: in the unsuppressed case, the combination of pump and probe pulse induces stimulated Raman scattering at the Raman resonances, leading to stimulated Raman loss (SRL) of the probe and and stimulated Raman gain (SRG) of the pump. The Raman spectrum then results from the difference between two spectra, recorded with pump on and off, respectively. In the suppressed case a second strong pump pulse, working as a depletion pulse, depletes the probe pulse via stimulated Raman scattering (SRLD) and induces a shortage of the probe photons at the Raman resonances, saturating the stimulated Raman scattering. Thus, only a small amount of additional SRLSup is induced by the original pump. If SRL is detected in addition to the spectral change, induced by the depletion pulse, the SRL will be reduced resulting in SRLSup<; SRL.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2019•1 citation
Based on the time-dependent theory, an analysis of the distinction between resonance Raman (RR) and resonance fluorescence (RF) with pulse excitation was presented. The real population of the intermediate state gives two optical components-the independent time evolution of intermediate ket and bra states generates RR while RF originates from the phase coherent between ket and bra states. In cw limit, the transition probability of spontaneous emission with pulse excitation can be reduced to the classical theory.
In the presence of coherent saturated near-resonant two-photon excitation, the ordinary Raman scattering line is replaced by a dynamic Stark shifted or Stark split doublet, and Rabi nutations appear in the time-resolved ordinary Raman spectrum. The relative intensity of the peaks of the doublet depends on the shape and on the average frequency of the exciting pulse. Striking new features arise from the interfering contributions of the upper and lower states of the two-photon transition to the Raman scattering process. The theory is applied to Raman scattering in atomic Na in the presence of the 3 2 S 1 2/(F=1, M F =1) to 4 2 D 3 2,5/2/(F=3,M F =3) two-photon resonances.
Summary form only given. Sub-diffraction limited imaging schemes have become widely used in fluorescence microscopy [1]. Howaever, the need for labeling with fluorescent dyes remains a major downside of fluorescence microscopy. The size, availability, toxicity as well as photo-bleaching of the used dyes can complicate measurements [2]. In contrast, Raman imaging is inherently label-free. Unfortunately, the super-resolution schemes used in fluorescence microscopy are currently not transferable to Raman microscopy. This paper presents the development of a scheme for the suppression of coherent Raman scattering through the depletion of probe photons, inspired by the work of M. Cho et al. [3, 4], who showed the suppression of coherent Raman scattering using laser pulses at three different wavelengths and two Raman resonances. In our case, probe depletion is achieved through saturated stimulated Raman scattering in a three-beam setup with only two colors involved. Fig. 1 (a) describes the working principle: in the unsuppressed case, the combination of pump and probe pulse induces stimulated Raman scattering at the Raman resonances, leading to stimulated Raman loss (SRL) of the probe and and stimulated Raman gain (SRG) of the pump. The Raman spectrum then results from the difference between two spectra, recorded with pump on and off, respectively. In the suppressed case a second strong pump pulse, working as a depletion pulse, depletes the probe pulse via stimulated Raman scattering (SRLD) and induces a shortage of the probe photons at the Raman resonances, saturating the stimulated Raman scattering. Thus, only a small amount of additional SRLSup is induced by the original pump. If SRL is detected in addition to the spectral change, induced by the depletion pulse, the SRL will be reduced resulting in SRLSup<; SRL.