Theoretical analysis of the new microwave detector based on a Josephson heterostructure

Igor A. Devyatov, M. Yu. Kupriyanov

Published Oct 23, 2009• 0 citations
Publisher

Abstract

We consider theoretically signal and noise properties of the new type of a high-sensitivity microwave detector, based on a SINIS (Superconductor-Insulator-Normal metal-Insulator-Superconductor) Josephson junction, in which the electron energy distribution function f(ε) in the nanoscale normal metal N region is nonequilibrium due to the capacitive coupling of this region with a receiving antenna. The deviation of f(ε) from the equilibrium leads to a change in the critical current Ic of the junction, i.e., in fact, to its inductance L = Φ0/2πIc (Φ0 ≈ 2.07*10-15 Wb is the magnetic flux quantum), which is the output signal of this device. Up to now there was no calculation of the noise properties of SINIS Josephson junction bolometer, taking into account non-equilibrium form of electron distribution function f(ε) in the normal metal absorber of this detector. We make this calculations and demonstrate, that noise parameter NEP of this detector is lower, than in others modern microwave detectors.

DOI
10.1117/12.854393

Related papers

Concept of a mixer based on a cold-electron bolometer

Michael A. Tarasov, L. S. Kuzmin

A phase-sensitive terahertz heterodyne mixer of a new type based on a cold-electron bolometer is proposed. In this mixer, a normal-metal thin-film absorber is connected to a planar antenna via superconductor-insulator-normal metal (SIN) tunnel junctions, thus forming a SINIS structure. The SINIS mixer combines the advantages of a hot-electron bolometer (HEB), such as a high signal frequency at a small local oscillator power, with the advantages of an SIS mixer, including low noise level, a high intermediate frequency, and wide working temperature range (up to a critical temperature of the superconductor). In contrast to the HEB and SIS mixers, the proposed device is less sensitive to external magnetic noise and exhibits no additional noise related to the superconducting transition and the Josephson effect.

Journal of Experimental and Theoretical Physics Letters•May 1, 2005•6 citations

High-sensitivity microwave detector based on a Josephson heterostructure

Igor A. Devyatov, M. Yu. Kupriyanov

The possibility of using the Josephson heterostructure composed of a nanoscale metallic absorber separated from superconducting strips by thin insulating layers as a high-sensitivity microwave detector has been considered theoretically. The inductive response of such a detector has been calculated and the influence of the nonequilibrium of the electron subsystem of the metallic absorber on its response has been analyzed. The limiting sensitivity of the proposed detector has been found.

Journal of Experimental and Theoretical Physics Letters•Jul 1, 2009•1 citation

Terahertz spectroscopy with a Josephson oscillator and a SINIS bolometer

Michael A. Tarasov, L. S. Kuzmin, Е. А. Степанцов +5 more

The voltage response of a thin-film normal-metal hot-electron bolometer based on a SINIS (superconductor-insulator-normal metal-insulator-superconductor) structure to the radiation of a high-temperature Josephson junction in the terahertz frequency region was measured. Bolometers were integrated with planar log-periodic and double-dipole antennas, and Josephson junctions were integrated with log-periodic antennas. Measurements showed that the Josephson junction at a temperature of 260 mK was overheated by the transport current, so that its electron temperature exceeded 3 K at a bias voltage of 1 mV. The maximum response of a bolometer with a double-dipole antenna was observed at a frequency of 300 GHz, which agreed well with the calculated value. The Josephson radiation was observed at frequencies up to 1.7 THz. The voltage response of a bolometer reached 4×10 8 V/W, and the total noise-equivalent power reached 1.5×10 −17 W/Hz 1/2 .

Journal of Experimental and Theoretical Physics Letters•Mar 1, 2004•10 citations

Microwave SINIS Detectors

Michael A. Tarasov, Aleksandra A. Gunbina, Artem M. Chekushkin +3 more

This review presents the main characteristics and mechanisms of operation of superconductor–insulator–normal metal–insulator–superconductor (SINIS) microwave detectors. An analysis of the detectors’ performance against a quantum detector and a photon counter is given. Methods for cooling a superconductor using normal metal traps and the role of electron cooling in optimizing the current response to terahertz radiation are discussed. Fabrication methods using shadow evaporation as well as magnetron sputtering are described.

Applied Sciences•Oct 18, 2022•11 citations

Optimal Cold-Electron Bolometer with a Superconductor-Insulator-Normal Tunnel Junction and an Andreev Contact

L. S. Kuzmin

A novel concept of the optimal Cold-Electron Bolometer (CEB) with a Superconductor-Insulator-Normal (SIN) Tunnel Junction and Andreev SN contact has been proposed. This concept has been developed to improve noise properties of the CEB by increasing current responsivity for SQUID readout (in voltage-biased mode) in comparison with classical CEB concept comprising two SIN tunnel junctions. In this configuration the power of incoming signal is not split between two series junctions and the current response of a single junction is twice larger in comparison with double junction structure. The signal is concentrated from antenna to an absorber through capacitance of the tunnel junction from one side and Andreev contact from another side. HF matching is realized by resistance of a normal metal absorber that is independent on tunnel junction parameters. The volume of a normal metal is partly squeezed due to proximity effect of a superconducting electrode from the Andreev contact that also increases efficiency of the electron cooling. The concept is based on direct electron cooling of the absorber by SIN tunnel junction that serves as negative electrothermal feedback for the signal. Noise properties are considerably improved by decreasing the electron temperature. Ultimate performance of the CEB is determined by optical load converted to shot noise of the signal readout. The goal is to achieve noise-equivalent power (NEP) of the CEB with standard SQUID readout less than photon noise. Ultimate NEP better than photon noise can be achieved practically in wide range of power loads from 0.1 fW (SPICA) to 30 pW (OLIMPO, CLOVER, PILOT). Applicability of the CEB to post-Herschel space missions looks very promising.

•May 1, 2006•3 citations

SINIS Bolometer with Microwave Readout

Michael A. Tarasov, Sumedh Mahashabde, Aleksandra A. Gunbina +9 more

Abstract A bolometer, which is based on a superconductor–insulator–normal metal–insulator–superconductor (SINIS) structure, integrated into a twin-slot antenna with a central frequency of 90 GHz, and connected with a superconducting microwave readout resonator, has been designed, fabricated, and experimentally studied. Such an elementary cell is designed for the multi-element array of a high-sensitive radioastronomic receiver, in which the readout from a great number of channels is performed by a single coaxial cable instead of separate wires and amplifier in each channel.

Physics of the Solid State•Sep 1, 2020•6 citations
We consider theoretically signal and noise properties of the new type of a high-sensitivity microwave detector, based on a SINIS (Superconductor-Insulator-Normal metal-Insulator-Superconductor) Josephson junction, in which the electron energy distribution function f(ε) in the nanoscale normal metal N region is nonequilibrium due to the capacitive coupling of this region with a receiving antenna. The deviation of f(ε) from the equilibrium leads to a change in the critical current Ic of the junction, i.e., in fact, to its inductance L = Φ0/2πIc (Φ0 ≈ 2.07*10-15 Wb is the magnetic flux quantum), which is the output signal of this device. Up to now there was no calculation of the noise properties of SINIS Josephson junction bolometer, taking into account non-equilibrium form of electron distribution function f(ε) in the normal metal absorber of this detector. We make this calculations and demonstrate, that noise parameter NEP of this detector is lower, than in others modern microwave detectors.
A phase-sensitive terahertz heterodyne mixer of a new type based on a cold-electron bolometer is proposed. In this mixer, a normal-metal thin-film absorber is connected to a planar antenna via superconductor-insulator-normal metal (SIN) tunnel junctions, thus forming a SINIS structure. The SINIS mixer combines the advantages of a hot-electron bolometer (HEB), such as a high signal frequency at a small local oscillator power, with the advantages of an SIS mixer, including low noise level, a high intermediate frequency, and wide working temperature range (up to a critical temperature of the superconductor). In contrast to the HEB and SIS mixers, the proposed device is less sensitive to external magnetic noise and exhibits no additional noise related to the superconducting transition and the Josephson effect.
The voltage response of a thin-film normal-metal hot-electron bolometer based on a SINIS (superconductor-insulator-normal metal-insulator-superconductor) structure to the radiation of a high-temperature Josephson junction in the terahertz frequency region was measured. Bolometers were integrated with planar log-periodic and double-dipole antennas, and Josephson junctions were integrated with log-periodic antennas. Measurements showed that the Josephson junction at a temperature of 260 mK was overheated by the transport current, so that its electron temperature exceeded 3 K at a bias voltage of 1 mV. The maximum response of a bolometer with a double-dipole antenna was observed at a frequency of 300 GHz, which agreed well with the calculated value. The Josephson radiation was observed at frequencies up to 1.7 THz. The voltage response of a bolometer reached 4×10 8 V/W, and the total noise-equivalent power reached 1.5×10 −17 W/Hz 1/2 .
This review presents the main characteristics and mechanisms of operation of superconductor–insulator–normal metal–insulator–superconductor (SINIS) microwave detectors. An analysis of the detectors’ performance against a quantum detector and a photon counter is given. Methods for cooling a superconductor using normal metal traps and the role of electron cooling in optimizing the current response to terahertz radiation are discussed. Fabrication methods using shadow evaporation as well as magnetron sputtering are described.
A novel concept of the optimal Cold-Electron Bolometer (CEB) with a Superconductor-Insulator-Normal (SIN) Tunnel Junction and Andreev SN contact has been proposed. This concept has been developed to improve noise properties of the CEB by increasing current responsivity for SQUID readout (in voltage-biased mode) in comparison with classical CEB concept comprising two SIN tunnel junctions. In this configuration the power of incoming signal is not split between two series junctions and the current response of a single junction is twice larger in comparison with double junction structure. The signal is concentrated from antenna to an absorber through capacitance of the tunnel junction from one side and Andreev contact from another side. HF matching is realized by resistance of a normal metal absorber that is independent on tunnel junction parameters. The volume of a normal metal is partly squeezed due to proximity effect of a superconducting electrode from the Andreev contact that also increases efficiency of the electron cooling. The concept is based on direct electron cooling of the absorber by SIN tunnel junction that serves as negative electrothermal feedback for the signal. Noise properties are considerably improved by decreasing the electron temperature. Ultimate performance of the CEB is determined by optical load converted to shot noise of the signal readout. The goal is to achieve noise-equivalent power (NEP) of the CEB with standard SQUID readout less than photon noise. Ultimate NEP better than photon noise can be achieved practically in wide range of power loads from 0.1 fW (SPICA) to 30 pW (OLIMPO, CLOVER, PILOT). Applicability of the CEB to post-Herschel space missions looks very promising.
Abstract A bolometer, which is based on a superconductor–insulator–normal metal–insulator–superconductor (SINIS) structure, integrated into a twin-slot antenna with a central frequency of 90 GHz, and connected with a superconducting microwave readout resonator, has been designed, fabricated, and experimentally studied. Such an elementary cell is designed for the multi-element array of a high-sensitive radioastronomic receiver, in which the readout from a great number of channels is performed by a single coaxial cable instead of separate wires and amplifier in each channel.