Journal of Applied Physics

Low-noise heterodyne mixing with NbN microbolometers at 800 GHz

Thomas Lehnert, Hermann Rothermel, K. H. Gundlach

Published Apr 1, 1998• 6 citations
Publisher

Abstract

Mixer performance of NbN transition edge microbolometers was investigated in a frequency range from 795 to 813 GHz. The devices consist of a parallel array of 3 NbN lines with submicron length patterned by e-beam lithography in a self-aligned process. The heterodyne mixer response was proven by means of two superposed oscillator signals at the receiver input and the observation of a discrete line in the output spectrum. Receiver noise temperatures, Trec, were determined by the hot/cold load Y-factor method in a quasioptical receiver at 4.2 K. The accessible intermediate frequency (IF) band was 1000 to 1750 MHz. We have compared devices with a NbN film thickness of 100 and 50 Å. Lowest receiver noise temperatures were obtained at 800 GHz. Uncorrected Trec values around 900 K were measured for both devices at a 1000 MHz IF frequency. For higher IF frequencies, Trec increased much less in the 50 Å device than in the 100 Å device. At 800 GHz and 1750 MHz IF frequency, Trec was only 1180 K. This result indicates that in an optimized NbN bolometric mixer the IF frequency band can extend to reasonable high values for radioastronomical applications.

DOI
10.1063/1.366623

Related papers

Low Noise NbN Phonon-Cooled Hot-Electron Bolometer Mixers at 810 GHz

C. Rösch, Thomas Lehnert, C. Schwoerer +4 more

NbN phonon-cooled superconducting hot-electron bolometric mixers with quasi-optical coupling were fabricated in a self-aligned process by means of e-beam-lithography. The mixer element consists of a 5 nm thick NbN film sputtered on a fused quartz substrate. Noise performance was investigated in the frequency range of 798 to 813 GHz for intermediate frequencies from 1.0 to 1.75 GHz. Uncorrected double sideband receiver noise temperatures of about 900 K were measured at an intermediate frequency of 1000 MHz with a 50 MHz bandpass filter. The gain bandwidth was determined by superposing two local oscillator signals and measuring the height of the discrete line at the intermediate frequency output. A 3dB-roll-off-frequency of some 1.3 GHz was obtained.

•Mar 1, 1998•1 citation

Performance of NbN lattice-cooled hot-electron bolometric mixers

Jonathan H. Kawamura, R. Blundell, Edward Tong +3 more

The heterodyne performance of lattice-cooled hot-electron bolometric mixers is measured at 200 GHz. Superconducting thin-film niobium nitride strips with ∼5 nm thickness are used as waveguide mixer elements. A double-sideband receiver noise temperature of 750 K at 244 GHz is measured at an intermediate frequency centered at 1.5 GHz with 500 MHz bandwidth and with 4.2 K device temperature. The instantaneous bandwidth for this mixer is 1.6 GHz. The local oscillator power required by the mixer is about 0.5 μW. The mixer is linear to within 1 dB up to an input power level 6 dB below the local oscillator power. A receiver incorporating a hot-electron bolometric mixer was used to detect molecular line emission in a laboratory gascell. This experiment unambiguously confirms that the receiver noise temperature determined from Y-factor measurements reflects the true heterodyne sensitivity.

Journal of Applied Physics•Oct 1, 1996•12 citations

Heterodyne measurements of a NbN superconducting hot electron mixer at terahertz frequencies

Pavel A. Yagoubov, M. Kroug, H. Merkel +6 more

The performance of a NbN based phonon-cooled Hot Electron Bolometric (HEB) quasioptical mixer is investigated in the 0.65-3.12 THz frequency range. The device is made from a 3 nm thick NbN film on high resistivity Si and integrated with a planar spiral antenna on the same substrate. The in-plane dimensions of the bolometer strip are 0.2/spl times/2 /spl mu/m. The best results of the DSB noise temperature at 1.5 GHz IF frequency obtained with one device are: 1300 K at 650 GHz, 4700 K at 2.5 THz and 10000 K at 3.12 THz. The measurements were performed at 4.5 K ambient temperature. The amount of local oscillator (LO) power absorbed in the bolometer is about 100 nW. The mixer is linear to within 1 dB compression up to the signal level 10 dB below that of the LO. The intrinsic single sideband conversion gain measured at 650 GHz is -9 dB, the total conversion gain is -14 dB.

IEEE Transactions on Applied Superconductivity•Jun 1, 1999•6 citations

Low noise NbN lattice-cooled superconducting hot-electron bolometric mixers at submillimeter wavelengths

Jonathan H. Kawamura, R. Blundell, Edward Tong +4 more

Lattice-cooled superconducting hot-electron bolometric mixers are used in a submillimeter-wave waveguide heterodyne receiver. The mixer elements are niobium nitride film with 3.5 nm thickness and ∼10 μm2 area. The local oscillator power for optimal performance is estimated to be 0.5 μW, and the instantaneous bandwidth is 2.2 GHz. At an intermediate frequency centered at 1.4 GHz with 200 MHz bandwidth, the double sideband receiver noise temperature is 410 K at 430 GHz. The receiver has been used to detect molecular line emission in a laboratory gas cell.

Applied Physics Letters•Mar 24, 1997•40 citations

Terahertz-frequency waveguide NbN hot-electron bolometer mixer

Jonathan H. Kawamura, Edward Tong, R. Blundell +5 more

We have developed a low-noise waveguide heterodyne receiver for operation near 1 THz using phonon-cooled NbN hot-electron bolometers. The mixer elements are submicron-sized microbridges of 4 nm-thick NbN film fabricated on a quartz substrate. Operating at a bath temperature of 4.2 K, the double-sideband receiver noise temperature is 760 K at 1.02 THz and 1100 K at 1.26 THz. The local oscillator is provided by solid-state sources, and power measured at the source is less than 1 /spl mu/W. The intermediate frequency bandwidth exceeds 2 GHz. The receiver was used to make the first ground-based heterodyne detection of a celestial spectroscopic line above 1 THz.

IEEE Transactions on Applied Superconductivity•Mar 1, 2001•24 citations

NbN Hot Electron Bolometric Mixers for a Quasi--Optical THz Receiver

M. Kroug

Experimental work on the development of a quasi-optical heterodyne receiver for the THz frequency range is reported. The mixing device is a superconducting hot electron bolometer (HEB) made from ultrathin, d = 3 - 5 nm, niobium nitride (NbN) films. Work described in this thesis comprises: The design of a prototype receiver using quasi-optical coupling. Device fabrication involving reactive magnetron sputtering of NbN films and lithographic definition of the antenna integrated mixer. An investigation of the receiver performance at frequencies between 0.6 THz and 2.5 THz. The best performance is obtained with HEB mixers made from NbN films with a thickness d = 3-3.5 nm and a critical temperature T c = 9 - 9.5 K. Double-side band receiver noise temperatures are 530 K at 0.6 THz, 650 K at 1.6 THz and 1100 K at 2.5 THz. Corrected for losses in the receiver input optics, these values amount to only 10 times the theoretical quantum limit. MgO as the substrate material has been shown to provide improved acoustic coupling between NbN film and the substrate compared to other materials such as Si or sapphire. A maximum IF gain bandwidth of 4.5 GHz has been measured under the same operating conditions which yield lowest noise temperature. The local oscilltor power requirement is ~250 nW absorbed in the bolometer. Quasi-optically coupled HEB mixers have become the device-of-choice for radio astronomical applications in the frequency regime at and above 1 THz.

•Jan 1, 2001•4 citations
Mixer performance of NbN transition edge microbolometers was investigated in a frequency range from 795 to 813 GHz. The devices consist of a parallel array of 3 NbN lines with submicron length patterned by e-beam lithography in a self-aligned process. The heterodyne mixer response was proven by means of two superposed oscillator signals at the receiver input and the observation of a discrete line in the output spectrum. Receiver noise temperatures, Trec, were determined by the hot/cold load Y-factor method in a quasioptical receiver at 4.2 K. The accessible intermediate frequency (IF) band was 1000 to 1750 MHz. We have compared devices with a NbN film thickness of 100 and 50 Å. Lowest receiver noise temperatures were obtained at 800 GHz. Uncorrected Trec values around 900 K were measured for both devices at a 1000 MHz IF frequency. For higher IF frequencies, Trec increased much less in the 50 Å device than in the 100 Å device. At 800 GHz and 1750 MHz IF frequency, Trec was only 1180 K. This result indicates that in an optimized NbN bolometric mixer the IF frequency band can extend to reasonable high values for radioastronomical applications.
NbN phonon-cooled superconducting hot-electron bolometric mixers with quasi-optical coupling were fabricated in a self-aligned process by means of e-beam-lithography. The mixer element consists of a 5 nm thick NbN film sputtered on a fused quartz substrate. Noise performance was investigated in the frequency range of 798 to 813 GHz for intermediate frequencies from 1.0 to 1.75 GHz. Uncorrected double sideband receiver noise temperatures of about 900 K were measured at an intermediate frequency of 1000 MHz with a 50 MHz bandpass filter. The gain bandwidth was determined by superposing two local oscillator signals and measuring the height of the discrete line at the intermediate frequency output. A 3dB-roll-off-frequency of some 1.3 GHz was obtained.
The heterodyne performance of lattice-cooled hot-electron bolometric mixers is measured at 200 GHz. Superconducting thin-film niobium nitride strips with ∼5 nm thickness are used as waveguide mixer elements. A double-sideband receiver noise temperature of 750 K at 244 GHz is measured at an intermediate frequency centered at 1.5 GHz with 500 MHz bandwidth and with 4.2 K device temperature. The instantaneous bandwidth for this mixer is 1.6 GHz. The local oscillator power required by the mixer is about 0.5 μW. The mixer is linear to within 1 dB up to an input power level 6 dB below the local oscillator power. A receiver incorporating a hot-electron bolometric mixer was used to detect molecular line emission in a laboratory gascell. This experiment unambiguously confirms that the receiver noise temperature determined from Y-factor measurements reflects the true heterodyne sensitivity.
The performance of a NbN based phonon-cooled Hot Electron Bolometric (HEB) quasioptical mixer is investigated in the 0.65-3.12 THz frequency range. The device is made from a 3 nm thick NbN film on high resistivity Si and integrated with a planar spiral antenna on the same substrate. The in-plane dimensions of the bolometer strip are 0.2/spl times/2 /spl mu/m. The best results of the DSB noise temperature at 1.5 GHz IF frequency obtained with one device are: 1300 K at 650 GHz, 4700 K at 2.5 THz and 10000 K at 3.12 THz. The measurements were performed at 4.5 K ambient temperature. The amount of local oscillator (LO) power absorbed in the bolometer is about 100 nW. The mixer is linear to within 1 dB compression up to the signal level 10 dB below that of the LO. The intrinsic single sideband conversion gain measured at 650 GHz is -9 dB, the total conversion gain is -14 dB.
Lattice-cooled superconducting hot-electron bolometric mixers are used in a submillimeter-wave waveguide heterodyne receiver. The mixer elements are niobium nitride film with 3.5 nm thickness and ∼10 μm2 area. The local oscillator power for optimal performance is estimated to be 0.5 μW, and the instantaneous bandwidth is 2.2 GHz. At an intermediate frequency centered at 1.4 GHz with 200 MHz bandwidth, the double sideband receiver noise temperature is 410 K at 430 GHz. The receiver has been used to detect molecular line emission in a laboratory gas cell.
We have developed a low-noise waveguide heterodyne receiver for operation near 1 THz using phonon-cooled NbN hot-electron bolometers. The mixer elements are submicron-sized microbridges of 4 nm-thick NbN film fabricated on a quartz substrate. Operating at a bath temperature of 4.2 K, the double-sideband receiver noise temperature is 760 K at 1.02 THz and 1100 K at 1.26 THz. The local oscillator is provided by solid-state sources, and power measured at the source is less than 1 /spl mu/W. The intermediate frequency bandwidth exceeds 2 GHz. The receiver was used to make the first ground-based heterodyne detection of a celestial spectroscopic line above 1 THz.
Experimental work on the development of a quasi-optical heterodyne receiver for the THz frequency range is reported. The mixing device is a superconducting hot electron bolometer (HEB) made from ultrathin, d = 3 - 5 nm, niobium nitride (NbN) films. Work described in this thesis comprises: The design of a prototype receiver using quasi-optical coupling. Device fabrication involving reactive magnetron sputtering of NbN films and lithographic definition of the antenna integrated mixer. An investigation of the receiver performance at frequencies between 0.6 THz and 2.5 THz. The best performance is obtained with HEB mixers made from NbN films with a thickness d = 3-3.5 nm and a critical temperature T c = 9 - 9.5 K. Double-side band receiver noise temperatures are 530 K at 0.6 THz, 650 K at 1.6 THz and 1100 K at 2.5 THz. Corrected for losses in the receiver input optics, these values amount to only 10 times the theoretical quantum limit. MgO as the substrate material has been shown to provide improved acoustic coupling between NbN film and the substrate compared to other materials such as Si or sapphire. A maximum IF gain bandwidth of 4.5 GHz has been measured under the same operating conditions which yield lowest noise temperature. The local oscilltor power requirement is ~250 nW absorbed in the bolometer. Quasi-optically coupled HEB mixers have become the device-of-choice for radio astronomical applications in the frequency regime at and above 1 THz.