The number of photons emitted in a short time interval by a single atom in the process of resonance fluorescence is measured, and it is shown that the probability distribution of this number is sub-Poissonian.
We have discussed the photon statistics of the spectral components of N-atom time-dependent resonance fluorescence. It is shown that in contrast to the stationary limit, sub-Poissonian photon statistics in the sidebands occur for any number N of atoms including the case N\ensuremath{\gg}1. Reduction in Mandel's parameters Q+1 is found with increasing numbers of atoms. The typical time for the presence of sub-Poissonian statistics is proportional to 1/N.
Statistics of fluorescence photons emitted by a single two-level atom interacting with a continuous wave laser field are analyzed. The photon-counting distribution is calculated for the so-called intermediate fluorescence photons, i.e., those counted during the time interval between instants at which photons are emitted. The result is a sub-Poissonian (narrower than Poisson) distribution, which agrees with experimental observations. This intermediate-photon distribution is used to calculate the average number of fluorescence photons, the second factorial moment of the photon-counting distribution, and Mandel’s Q parameter commonly used to evaluate the deviation of photon statistics from the Poisson distribution. The theoretical expressions obtained for moments of the intermediate-photon distribution are different from well-known Mandel’s formulas.
The method previously used by the author for the measurement and calculation of the distribution function w N(T)of fluorescence photons from a single two-level atom that is continuously excited by laser light and has a unity fluorescence quantum yield is generalized to the case of a single molecule whose fluorescence quantum yield is smaller than unity and to the case of a three-level molecule whose fluorescence is blinking. The functions w N(T) calculated for these two cases demonstrate a sub-Poissonian distribution of fluorescence photons.
According to the exact solution of a two-level atomic system interacting with a single-mode field in a cavity and including a pumping mechanism, sub-Poissonian photon statistics can be generated either by regular pumping or by resonance absorption of the lower level. When the atomic lifetime is much smaller than the interaction time (${\ensuremath{\gamma}}_{\mathit{a}\mathit{b}}$\ensuremath{\tau}\ensuremath{\gg}1), which corresponds to a usual laser system, the sub-Poissonian photon distribution can be obtained only by regular pumping. On the other hand, if the atomic lifetime is comparable with the interaction time (${\ensuremath{\gamma}}_{\mathit{a}\mathit{b}}$\ensuremath{\tau}\ensuremath{\le}1), the sub-Poissonian photon distribution can be generated by both mechanisms.
We study the general properties of the photon statistics of fluorescence radiation, emitted by a two-level atom in a strong laser field and a perturber bath. We investigate the deviation of the factorial moments from a Poisson distribution, and we show that for long counting times the lowest-order correction can be expressed entirely by the quantity Q, which represents the deviation of the variance from the average. We introduce and evaluate the quantities gn(t), which serve as a measure for the deviation of the higher-order statistics from Poissonian statistics. Subsequently we obtain explicit expressions for the average waiting time for the appearance of the n th photon, after an arbitrary initialization of the counting process. It turns out that the average time delay is again determined by Q. Hence this parameter can be measured in a photon-counting experiment, which involves only the observation of a single photon, rather than an (in principle) infinite number of photons.