Two different kinds of planar interferometers with two Nb-NbOx-PbIn junctions have been fabricated. The effects of a magnetic field coupled both to the loop and to the junctions have been investigated. A comparison of the experimental results with the theory is reported.
Resonances in the current-voltage characteristics of interferometers with two Nb-NbOx-Pb window junctions have been experimentally investigated. The data are compared with the theoretical curves computed both for the voltage and for the magnetic field dependence of the resonance amplitudes. Very good agreement is found in all the range of values of the damping parameter Γ=I0 R/Vr, where Vr is the resonant voltage and I0 and R are the maximum Josephson current and the parallel resistance of each junction. New features that cannot be explained in terms of the existing theory have been observed in devices with larger values of the parameter β=2πLI0/Φ0, where L is the loop inductance, and Φ0 is the flux quantum.
The growing interest in the development of nano-superconducting quantum interference devices (nanoSQUIDs) and their applications in nanoscience demands a deep study of these ultra-high-sensitivity nanodevices. In this paper, the main features of niobium planar nanointerferometers as a function of the temperature have been investigated. In particular, two types of nanodevices have been realized and studied: one based on nanobridges and the other on sub-micron Josephson tunnel junctions (JTJs). The nanobridge-based nanointerferometer, fabricated by electron beam lithography (EBL), consists of a sub-micrometric loop (effective area of 0.5 μ m 2 ), interrupted by two Dayem nanobridges having a width and length of 50 and 80 nm respectively. The JTJs-based nanointerferometer has two Nb/Al-AlO x /Nb SNIS (superconductor/normal-insulator/superconductor) junctions with an area of 0.09 μ m 2 , connected by a rectangular loop (1 μ m × 0.2 μ m), and realized by the three-dimensional focused ion beam (3D FIB) sculpting technique. For both nanodevices, measurements of current–voltage characteristics and critical current versus external magnetic flux have been performed at operating temperatures ranging from 4.2 to 1.2 K. The critical current modulation depths, magnetic flux to current transfer factor (current responsivity) and magnetic flux resolution as a function of the temperature have been evaluated for both nanosensors. Furthermore, measurements of the voltage–magnetic flux characteristics and the spectral density of magnetic flux noise have been performed at T = 4.2 K.