This paper proposes a realistically feasible experiment, within the realm of existing technology and proved techniques, to measure the mean photon number of a coherent source by means of a quantum non-demolition scheme, exploiting the parametric amplification of correlated photons in χ (2) media. We deduce the number of photons of an input source interacting with a high-intensity pump field in a nonlinear crystal, using as the probe the shift in the quadrature amplitude of the pump beam induced by the source under measurement. We perform a theoretical evaluation of the noise level associated with this measurement and compare it with the quantum limit. We explore the possible implications of this method for radiometry.
This paper proposes a realistically feasible experiment, within the realm of existing technology and proved techniques, to measure the mean photon number of a coherent source by means of a quantum non-demolition scheme, exploiting the parametric amplification of correlated photons in χ (2) media. We deduce the number of photons of an input source interacting with a high-intensity pump field in a nonlinear crystal, using as the probe the shift in the quadrature amplitude of the pump beam induced by the source under measurement. We perform a theoretical evaluation of the noise level associated with this measurement and compare it with the quantum limit. We explore the possible implications of this method for radiometry.
The aim of this paper is to present a possible experiment for measuring photon number by a non-demolitive scheme. We show that, in principle, it is possible to deduce the number of photons of an intense pump coherent field by measuring the phase-shift on two frequency conjugated beams due to the interaction with the pump in a nonlinear crystal, which exhibits χ(2) nonlinearity. We perform a theoretical evaluation of the relative uncertainty associated to the photon number measurement, obtaining high accuracy results when high pump power levels, low coupling between pump and crystal and squeezing generators are used. The accuracy obtained are compared with results obtainable with a beam splitter setup.
When atoms are illuminated by an off-resonant field, the AC Stark effect will lead to phase shifts in atomic states. The phase shifts are proportional to the photon number of the off-resonant illuminating field. By measuring the atomic phase with newly developed atom-light hybrid interferometers, we can achieve quantum non-demolition measurement of the photon number of the optical field. In this paper, we analyze theoretically the performance of this QND measurement scheme by using the QND measurement criteria established by Holland et al [Phys. Rev. A 42, 2995 (1990)]. We find the quality of the QND measurement depends on the phase resolution of the atom-light hybrid interferometers. We apply this QND measurement scheme to a twin-photon state from parametric amplifier to verify the photon correlation in the twin beams. Furthermore, a sequential QND measurement procedure is analyzed for verifying the projection property of quantum measurement and for the quantum information tapping. Finally, we discuss the possibility for single-photon-number-resolving detection via QND measurement.
The accuracy of optical measurements at low light levels is limited by the quantum noise of the source and by the random nature of the interaction with the measured object. The source noise may be reduced by use of nonclassical photon-number squeezed light. We consider the use of two photon-correlated beams (generated, for example, by spontaneous parametric downconversion) to measure the optical transmittance of an object. The photons of each beam obey a random Poisson process but are synchronized in time. One beam is used to probe the object, and the other is used as a reference providing information on the realization of the random arrival of photons at the object. The additional information available by such measurement may be exploited to improve the accuracy of the measurement. Various estimators, including the maximum-likelihood estimator, are considered, and their performance is evaluated and compared with the measurement based on a single-beam conventional (Poissonian) source and a maximally squeezed (fixed-photon-number) source. The performance advantage that is established depends on parameters such as the intensity of the source, the transmittance of the object, the quantum efficiency of the detectors, the background noise, and the degree of correlation of the photon numbers in the two beams.
Abstract In this review we present the potentialities and the achievements of the use of non-classical photon-number correlations in twin-beam states for many applications, ranging from imaging to metrology. Photon-number correlations in the quantum regime are easily produced and are rather robust against unavoidable experimental losses, and noise in some cases, if compared to the entanglement, where losing one photon can completely compromise the state and its exploitable advantages. Here, we will focus on quantum enhanced protocols in which only phase-insensitive intensity measurements (photon-number counting) are performed, which allow probing the transmission/absorption properties of a system, leading, for example, to innovative target detection schemes in a strong background. In this framework, one of the advantages is that the sources experimentally available emit a wide number of pair-wise correlated modes, which can be intercepted and exploited separately, for example by many pixels of a camera, providing a parallelism, essential in several applications, such as wide-field sub-shot-noise imaging and quantum enhanced ghost imaging. Finally, non-classical correlation enables new possibilities in quantum radiometry, e.g. the possibility of absolute calibration of a spatial resolving detector from the on-off single-photon regime to the linear regime in the same setup.
Direct measurement of quantum non-Gaussianity requires some variant of a discrete photon-resolving detection, which is feasible only for low mean photon numbers. For a large mean photon number, intensity detection by linear photodiodes provides a continuous signal; therefore, the Fock probabilities of the unknown input state are not directly available. On the other hand, intensity moments can be measured directly, and photon-number moments can be estimated. Therefore, we derive and analyze a quantum non-Gaussianity witness based solely on the photon-number mean and variance (or alternatively, the second-order correlation g ( 2 ) ) of an unknown state. Due to the simplicity of the used photon-number moments, the measurement results are easy to correct for losses and additive noise. We provide examples of simple amplification-based measurement schemes where our witness can be applied directly, thereby opening pathways to proof-of-principle tests and applications.
Quantum non-demolition (QND) measurement is an important tool in the fields of quantum information processing and quantum optics. The atom-light hybrid interferometer is of great interest due to its combination of an atomic spin wave and an optical wave, which can be utilized for photon number QND measurement via the AC-Stark effect. In this paper, we present an SU(1,1)-SU(2)-concatenated atom-light hybrid interferometer, and theoretically study QND measurement of the photon number. Compared to the traditional SU(2) interferometer, the signal-to-noise ratio in a balanced case is improved by a gain factor of the nonlinear Raman process (NRP) in this proposed interferometer. Furthermore, the condition of high-quality QND measurement is analyzed. In the presence of losses, the measurement quality is reduced. We can adjust the gain parameter of the NRP in the readout stage to reduce the impact due to losses. Moreover, this scheme is a multiarm interferometer, which has the potential of multiparameter estimation with many important applications in the detection of vector fields, quantum imaging, and so on.