Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Quadrupole perturbation effects upon the Hg201 magnetic resonance. I. Effects upon free precession of the nuclear spins

Philip Heimann

Published Mar 1, 1981• 10 citations
Publisher

Abstract

The time dependence of free-precession signals from an ensemble of spin-$\frac{3}{2}$ atoms in the presence of a quadrupole perturbation is calculated by examining the time dependence of the density matrix which describes the ensemble. The calculations yield explicit expressions for signals obtained using either a linearly or elliptically polarized off-resonant readout light, applied to a mixture of orientation, alignment, and octupole spin distributions. The results are obtained by expressing the density matrix in terms of spherical basis operators. The theoretical predictions are in good agreement with experimental results which are characterized by "beats" in the decay transients of signals from $^{201}\mathrm{Hg}$.

DOI
10.1103/physreva.23.1204

Related papers

Quadrupole effects on nuclear-magnetic-resonance gyroscopes

Yue Chang, Shuangai Wan, Jie Qin

Nuclear-magnetic-resonance gyroscopes that detect rotation as a shift in the precession frequency of nuclear spins have attracted a lot of attention. Under a feedback-generated drive, the precession frequency in the steady state is supposed to be dependent only on the angular momentum and an applied magnetic field. However, nuclei with spins larger than 1/2 experience electric quadrupole interaction with electric-field gradients at the cell walls. This quadrupole interaction shifts the precession frequencies of the nuclear spins, which brings inaccuracy to the rotation measurement as the quadrupole interaction constant ${C}_{q}$ is difficult to precisely measure. In this paper, the effects of quadrupole interaction on nuclear-magnetic-resonance gyroscopes are theoretically studied. We find that, when the constant ${C}_{q}$ is small compared to the characteristic decay rate of the system, which is the case in most gyroscopes for practical use, as the strength of the feedback-driving field increases, the quadrupole shift monotonically decreases, regardless of the system parameters in including ${C}_{q}$. Furthermore, the larger driving amplitude can reduce the quadrupole shift's fluctuation caused by fluctuations of the system parameters, and, thus, it can reduce systematic errors resulted from the quadrupole interaction. In the large-${C}_{q}$ regime, more than one precession frequency exists, and the nuclear spins may precess with a single frequency or multifrequencies depending on initial conditions. In this regime with large driving amplitudes, the nuclear spin can restore the single-frequency precession. These results are obtained by solving an effective master equation of the nuclear spins in a rotating frame from which both the steady-state solutions and the dynamics of the system are shown.

arXiv:1912.00216•Physical Review A•Jul 9, 2020•5 citations

Effect of light ellipticity and polarization angle on the transient dynamics of the ground-state Hanle effect

Raghwinder Singh Grewal

Abstract We report theoretical investigations on the transient dynamics of the ground-state Hanle effect in the Voigt geometry, where a time-varying scanning magnetic field B (t) is applied perpendicular to the light propagation direction. Transient Hanle signals are calculated for different light polarizations using a theoretical model based on the density matrix approach. First, we study the ellipticity dependence of transient Hanle signals in two configurations in which the major axis of the light polarization ellipse ( ε a ) is aligned either perpendicular or parallel to the field B . For ε a ⊥ B , elliptical polarization of the light produces oscillations of frequencies 2ΩL(t) and ΩL(t) simultaneously, where ΩL(t) is the Larmor frequency of the corresponding field B (t). On the other hand, in the case of ε a || B , only ΩL(t) oscillation is observed using elliptically polarized light. Second, we vary the tilt angle between the polarization vector of a linearly polarized light and the orientation of the field B and study its effect on the transient response of Hanle signals. Both the amplitude and the decay rate of the oscillations show a strong dependence on the light ellipticity and tilt angle of the polarization vector. In addition, the influence of the magnetic field sweep rate on the transient signals is demonstrated for given values of light ellipticity and polarization angle.

Journal of Optics•Nov 9, 2023•3 citations

Spin alignment based Rb-87 magnetometry with free spin precession

Yang Li, Lulu Zhang, Yongbiao Yang +4 more

Spin alignment based Rb-87 magnetometry with free spin precession has been proposed. A 795-nm linearly polarized laser beam, serving as the pump beam and the probe beam, propagates through a cylindrical Rb-87 enriched atomic vapor cell along the Z axis, with the polarization orientation aligned along the Y axis. Simultaneously, the static magnetic field B0⃗ is applied along the Y axis, and the π/2 pulse radio-frequency (RF) magnetic field BRF⃗ is applied along the Z axis. Given that the laser polarization direction aligns with the static magnetic field, the pump beam exhibits π polarization. This induces a symmetric population distribution of ground-state atoms across the Zeeman sublevels. This leads to the generation of a magnetic quadrupole moment, thereby facilitating the formation of the spin alignment state. The π/2 pulse RF magnetic field aligns the magnetic quadrupole moment with the direction of the RF magnetic field. Upon the cessation of the RF magnetic field, the magnetic quadrupole moment undergoes precession around the static magnetic field. The linearly polarized probe beam, in conjunction with a balanced polarimeter comprising a true zero-order half-wave plate, a Wollaston prism, and a balanced differential photodiode, is employed to measure the free precession decay signal. In this magnetometry system, both the pump power and the RF magnetic field strength have been optimized. The sensitivity of the spin alignment based Rb-87 magnetometry with free spin precession is about 1.7 pT/Hz1/2.

Review of Scientific Instruments•Mar 1, 2025•0 citations

Coherence in freely precessing Ne21 and a test of linearity of quantum mechanics

T. E. Chupp, Rohan J. Hoare

We have observed coherence among the four magnetic sublevels of freely precessing $^{21}\mathrm{Ne}$ for times of 4.5 h. This has allowed direct detection of the quadrupole component of coherence relaxation and a test of linearity of quantum mechanics. The quadrupole component of relxation is evident in the different relaxation rates for the three lines of the NMR spectrum. Nonlinear corrections to quantum mechanics are found to be less than 1.6\ifmmode\times\else\texttimes\fi{}${10}^{\mathrm{\ensuremath{-}}26}$ of the binding energy per nucleon of $^{21}\mathrm{Ne}$.

Physical Review Letters•May 7, 1990•76 citations

Zero-field optical magnetometer based on spin alignment

Adil Meraki, L. Elson, N.J. Ho +4 more

Optically pumped magnetometers are important instruments for imaging biological magnetic signals without the need for cryogenic cooling. These magnetometers are presently available in the commercial market and utilize the principles of atomic alignment or orientation, enabling remarkable sensitivity and precision in the measurement of magnetic fields. This research focuses on utilizing a spin-aligned atomic ensemble for magnetometry at zero field. An approach is introduced which involves evaluating how the linear polarization of light rotates as it passes through the atomic vapor to null the magnetic field. Analytical expressions are derived for the resulting spin alignment and photodetection signals. Experimental results are provided, demonstrating good agreement with the theoretical predictions. The sensitivity and bandwidth of the magnetometer are characterized based on the detected polarization rotation signal. Lastly, the practical utility of the magnetometer for medical applications is demonstrated by successfully detecting a synthetic cardiac signal.

arXiv:2308.12233•Physical Review A•Dec 11, 2023•19 citations

Tensor operator formalism for multiple-quantum NMR. 4. Spin- nuclei with an asymmetry term in the quadrupole Hamiltonian

Graham J. Bowden, W. D. Hutchison

Journal of Magnetic Resonance (1969)•Mar 1, 1987•6 citations
The time dependence of free-precession signals from an ensemble of spin-32\frac{3}{2}23​ atoms in the presence of a quadrupole perturbation is calculated by examining the time dependence of the density matrix which describes the ensemble. The calculations yield explicit expressions for signals obtained using either a linearly or elliptically polarized off-resonant readout light, applied to a mixture of orientation, alignment, and octupole spin distributions. The results are obtained by expressing the density matrix in terms of spherical basis operators. The theoretical predictions are in good agreement with experimental results which are characterized by "beats" in the decay transients of signals from 201Hg^{201}\mathrm{Hg}201Hg.
Nuclear-magnetic-resonance gyroscopes that detect rotation as a shift in the precession frequency of nuclear spins have attracted a lot of attention. Under a feedback-generated drive, the precession frequency in the steady state is supposed to be dependent only on the angular momentum and an applied magnetic field. However, nuclei with spins larger than 1/2 experience electric quadrupole interaction with electric-field gradients at the cell walls. This quadrupole interaction shifts the precession frequencies of the nuclear spins, which brings inaccuracy to the rotation measurement as the quadrupole interaction constant Cq{C}_{q}Cq​ is difficult to precisely measure. In this paper, the effects of quadrupole interaction on nuclear-magnetic-resonance gyroscopes are theoretically studied. We find that, when the constant Cq{C}_{q}Cq​ is small compared to the characteristic decay rate of the system, which is the case in most gyroscopes for practical use, as the strength of the feedback-driving field increases, the quadrupole shift monotonically decreases, regardless of the system parameters in including Cq{C}_{q}Cq​. Furthermore, the larger driving amplitude can reduce the quadrupole shift's fluctuation caused by fluctuations of the system parameters, and, thus, it can reduce systematic errors resulted from the quadrupole interaction. In the large-Cq{C}_{q}Cq​ regime, more than one precession frequency exists, and the nuclear spins may precess with a single frequency or multifrequencies depending on initial conditions. In this regime with large driving amplitudes, the nuclear spin can restore the single-frequency precession. These results are obtained by solving an effective master equation of the nuclear spins in a rotating frame from which both the steady-state solutions and the dynamics of the system are shown.
Abstract We report theoretical investigations on the transient dynamics of the ground-state Hanle effect in the Voigt geometry, where a time-varying scanning magnetic field B (t) is applied perpendicular to the light propagation direction. Transient Hanle signals are calculated for different light polarizations using a theoretical model based on the density matrix approach. First, we study the ellipticity dependence of transient Hanle signals in two configurations in which the major axis of the light polarization ellipse ( ε a ) is aligned either perpendicular or parallel to the field B . For ε a ⊥ B , elliptical polarization of the light produces oscillations of frequencies 2ΩL(t) and ΩL(t) simultaneously, where ΩL(t) is the Larmor frequency of the corresponding field B (t). On the other hand, in the case of ε a || B , only ΩL(t) oscillation is observed using elliptically polarized light. Second, we vary the tilt angle between the polarization vector of a linearly polarized light and the orientation of the field B and study its effect on the transient response of Hanle signals. Both the amplitude and the decay rate of the oscillations show a strong dependence on the light ellipticity and tilt angle of the polarization vector. In addition, the influence of the magnetic field sweep rate on the transient signals is demonstrated for given values of light ellipticity and polarization angle.
Spin alignment based Rb-87 magnetometry with free spin precession has been proposed. A 795-nm linearly polarized laser beam, serving as the pump beam and the probe beam, propagates through a cylindrical Rb-87 enriched atomic vapor cell along the Z axis, with the polarization orientation aligned along the Y axis. Simultaneously, the static magnetic field B0⃗ is applied along the Y axis, and the π/2 pulse radio-frequency (RF) magnetic field BRF⃗ is applied along the Z axis. Given that the laser polarization direction aligns with the static magnetic field, the pump beam exhibits π polarization. This induces a symmetric population distribution of ground-state atoms across the Zeeman sublevels. This leads to the generation of a magnetic quadrupole moment, thereby facilitating the formation of the spin alignment state. The π/2 pulse RF magnetic field aligns the magnetic quadrupole moment with the direction of the RF magnetic field. Upon the cessation of the RF magnetic field, the magnetic quadrupole moment undergoes precession around the static magnetic field. The linearly polarized probe beam, in conjunction with a balanced polarimeter comprising a true zero-order half-wave plate, a Wollaston prism, and a balanced differential photodiode, is employed to measure the free precession decay signal. In this magnetometry system, both the pump power and the RF magnetic field strength have been optimized. The sensitivity of the spin alignment based Rb-87 magnetometry with free spin precession is about 1.7 pT/Hz1/2.
We have observed coherence among the four magnetic sublevels of freely precessing 21Ne^{21}\mathrm{Ne}21Ne for times of 4.5 h. This has allowed direct detection of the quadrupole component of coherence relaxation and a test of linearity of quantum mechanics. The quadrupole component of relxation is evident in the different relaxation rates for the three lines of the NMR spectrum. Nonlinear corrections to quantum mechanics are found to be less than 1.6\ifmmode\times\else\texttimes\fi{}${10}^{\mathrm{\ensuremath{-}}26}$ of the binding energy per nucleon of 21Ne^{21}\mathrm{Ne}21Ne.
Optically pumped magnetometers are important instruments for imaging biological magnetic signals without the need for cryogenic cooling. These magnetometers are presently available in the commercial market and utilize the principles of atomic alignment or orientation, enabling remarkable sensitivity and precision in the measurement of magnetic fields. This research focuses on utilizing a spin-aligned atomic ensemble for magnetometry at zero field. An approach is introduced which involves evaluating how the linear polarization of light rotates as it passes through the atomic vapor to null the magnetic field. Analytical expressions are derived for the resulting spin alignment and photodetection signals. Experimental results are provided, demonstrating good agreement with the theoretical predictions. The sensitivity and bandwidth of the magnetometer are characterized based on the detected polarization rotation signal. Lastly, the practical utility of the magnetometer for medical applications is demonstrated by successfully detecting a synthetic cardiac signal.