Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics Letters

High-Tc super conducting quantum interference devices with slots or holes: Low 1/f noise in ambient magnetic fields

E. Dantsker, Saburo Tanaka, John L. Clarke

Published Apr 14, 1997• 168 citations
Publisher

Abstract

High-transition temperature dc superconducting quantum interference devices (SQUIDs) have been fabricated with arrays of slots or holes patterned in the 186×204 μm2 washers. In two designs, with seven slots or 248 holes, the linewidth of the remaining YBa2Cu3O7−x film was 4 μm. These devices exhibited virtually no increase in their low-frequency noise when they were cooled in static magnetic fields up to a certain threshold, above 100 μT in the best case. Furthermore, the mutual inductance between these devices and a seven-turn, spiral coil was at least 85% of that for a solid SQUID with the same outer dimensions.

DOI
10.1063/1.118776

Related papers

Reduction of 1/f noise in high-T c dc superconducting quantum interference devices cooled in an ambient magnetic field

E. Dantsker, Saburo Tanaka, P.-Å. Nilsson +2 more

The spectral density SΦ(f ) of the low-frequency 1/f noise of high transition temperature dc superconducting quantum interference devices (SQUIDs) with narrow linewidths was independent of B0, the magnetic field in which they were cooled, up to a threshold value, about 33 μT in the best case. Above this threshold, which is associated with the entry of flux vortices into the film, the noise increased rapidly. By contrast, for large square washer SQUIDs, SΦ(f ) scaled linearly with B0. Estimates indicate that the 1/f flux noise produced by the pickup loop of a directly coupled magnetometer is negligible.

Applied Physics Letters•Dec 23, 1996•104 citations

Characterization of the low-frequency noise in high-temperature radio frequency superconducting quantum interference devices cooled in static magnetic fields

J. Borgmann, P. David, Raphael Otto +2 more

We have performed a study of the low-frequency noise in high-temperature radio frequency (rf) superconducting quantum interference devices (SQUIDs) cooled in static magnetic fields. At 77 K, the noise of different thin-film YB2C3O7−x washer rf SQUIDs was measured in static magnetic fields up to 55 μT. The SQUID inductances ranged from 150 to 300 pH. The measured low-frequency flux noise of the SQUIDs SΦ1/2 at 1 Hz was between 70 and 350 μΦ0/√Hz, and in terms of magnetic field noise SB1/2 between 120 and 1100 fT/√Hz. The low-frequency noise of all devices at 1 Hz showed no significant increase for all applied static fields.

Applied Physics Letters•Feb 15, 1999•1 citation

Sub-μm linewidth input coils for low T c integrated thin-film dc superconducting quantum interference devices

M. B. Ketchen, Kevin G. Stawiasz, Dale J. Pearson +6 more

We have, for the first time, demonstrated integrated dc superconducting quantum interference devices (SQUIDs) with input coils of linewidth down to 0.5 μm. The SQUID inductance L consists of a single octagonal washer or two or four such washers configured in parallel. The input coil of inductance Li, which couples to L with a mutual inductance of Mi, consists of fine-line octagonal spiral(s) fabricated in close proximity to the washer(s). For a two-washer SQUID with twin 80-turn, 0.5 μm spirals, Li=2.5 μH, Mi=12.7 nH, L=109 pH, and the coupling constant k2=0.85. This entire device occupies an area of less than 0.2 mm2.

Applied Physics Letters•Jul 20, 1992•22 citations

High-Tc superconducting detector for highly-sensitive microwave magnetometry

F. Couëdo, Eliana Recoba Pawlowski, Julien Kermorvant +8 more

We have fabricated arrays of High-Tc Superconducting Quantum Interference Devices (SQUIDs) with randomly distributed loop sizes as sensitive detectors for Radio Frequency (RF) waves. These subwavelength size devices known as Superconducting Quantum Interference Filters (SQIFs) detect the magnetic component of the electromagnetic field. We used a scalable ion irradiation technique to pattern the circuits and engineer the Josephson junctions needed to make SQUIDs. Here, we report on a 300 SQUID series array with the loop area ranging from 6 to 60 μm2, folded in a meander line covering a 3.5 mm × 120 μm substrate area, made out of a 150 nm thick YBa2Cu3O7 film. Operating at a temperature of T = 66 K in an unshielded magnetic environment under low DC bias current (I = 60 μA) and a DC magnetic field (B = 3 μT), this SQIF can detect a magnetic field of a few picoteslas at a frequency of 1.125 GHz, which corresponds to a sensitivity of a few hundreds of fT/Hz and shows a linear response over 7 decades in RF power. This work is a promising approach for the realization of low dissipative subwavelength gigahertz magnetometers.

arXiv:1901.08786•Applied Physics Letters•May 13, 2019•29 citations

High-temperature dc superconducting quantum interference device with deep-submicron YBa2Cu3O7 weak links

Suzanne E. Romaine, Paul M. Mankiewich, William J. Skocpol +1 more

We have fabricated a YBa2Cu3O7 (YBCO) thin-film dc superconducting quantum interference device (SQUID) with lithographically defined deep-submicron weak links. At 77 K the voltage response to dc flux is sinusoidal and nonhysteretic, with maximum peak-to-peak amplitude of 5 μV. The maximum response is 8 μV at 70 K, where 2LI0/Φ0≊1. At lower temperatures, the maximum response oscillates in the range 4–6 μV. Random telegraph noise was observed near 30–40 K. Well-behaved Shapiro steps were observable at all measured temperatures below Tc.

Applied Physics Letters•Nov 11, 1991•5 citations

Ultra-low-noise tunnel junction dc SQUID with a tightly coupled planar input coil

M. B. Ketchen, J. M. Jaycox

We present a new superconducting quantum interference device (SQUID) that combines ultra-low-noise performance with tight coupling to a useable input coil. The inductive loop of the SQUID consists of a superconducting square washer that is slit in a low inductance fashion from its central hole to an outside edge where two Josephson tunnel junctions are incorporated. The inductance of the SQUID is about 90 pH, and each junction has a critical current of 15 μA and a resistive shunt of 4.5 Ω. The 190-nH input coil is a planar spiral of 50 turns situated immediately above the washer and coupled to the SQUID with a coupling constant k2 of 0.86. The SQUID has a minimum coupled energy sensitivity of 19h at 4.2 K and 8h at 1.5 K, in good agreement with theory. The crossover between white and low frequency noise occurs at ∼250 Hz.

Applied Physics Letters•Apr 15, 1982•248 citations
High-transition temperature dc superconducting quantum interference devices (SQUIDs) have been fabricated with arrays of slots or holes patterned in the 186×204 μm2 washers. In two designs, with seven slots or 248 holes, the linewidth of the remaining YBa2Cu3O7−x film was 4 μm. These devices exhibited virtually no increase in their low-frequency noise when they were cooled in static magnetic fields up to a certain threshold, above 100 μT in the best case. Furthermore, the mutual inductance between these devices and a seven-turn, spiral coil was at least 85% of that for a solid SQUID with the same outer dimensions.
The spectral density SΦ(f ) of the low-frequency 1/f noise of high transition temperature dc superconducting quantum interference devices (SQUIDs) with narrow linewidths was independent of B0, the magnetic field in which they were cooled, up to a threshold value, about 33 μT in the best case. Above this threshold, which is associated with the entry of flux vortices into the film, the noise increased rapidly. By contrast, for large square washer SQUIDs, SΦ(f ) scaled linearly with B0. Estimates indicate that the 1/f flux noise produced by the pickup loop of a directly coupled magnetometer is negligible.
We have performed a study of the low-frequency noise in high-temperature radio frequency (rf) superconducting quantum interference devices (SQUIDs) cooled in static magnetic fields. At 77 K, the noise of different thin-film YB2C3O7−x washer rf SQUIDs was measured in static magnetic fields up to 55 μT. The SQUID inductances ranged from 150 to 300 pH. The measured low-frequency flux noise of the SQUIDs SΦ1/2 at 1 Hz was between 70 and 350 μΦ0/√Hz, and in terms of magnetic field noise SB1/2 between 120 and 1100 fT/√Hz. The low-frequency noise of all devices at 1 Hz showed no significant increase for all applied static fields.
We have, for the first time, demonstrated integrated dc superconducting quantum interference devices (SQUIDs) with input coils of linewidth down to 0.5 μm. The SQUID inductance L consists of a single octagonal washer or two or four such washers configured in parallel. The input coil of inductance Li, which couples to L with a mutual inductance of Mi, consists of fine-line octagonal spiral(s) fabricated in close proximity to the washer(s). For a two-washer SQUID with twin 80-turn, 0.5 μm spirals, Li=2.5 μH, Mi=12.7 nH, L=109 pH, and the coupling constant k2=0.85. This entire device occupies an area of less than 0.2 mm2.
We have fabricated arrays of High-Tc Superconducting Quantum Interference Devices (SQUIDs) with randomly distributed loop sizes as sensitive detectors for Radio Frequency (RF) waves. These subwavelength size devices known as Superconducting Quantum Interference Filters (SQIFs) detect the magnetic component of the electromagnetic field. We used a scalable ion irradiation technique to pattern the circuits and engineer the Josephson junctions needed to make SQUIDs. Here, we report on a 300 SQUID series array with the loop area ranging from 6 to 60 μm2, folded in a meander line covering a 3.5 mm × 120 μm substrate area, made out of a 150 nm thick YBa2Cu3O7 film. Operating at a temperature of T = 66 K in an unshielded magnetic environment under low DC bias current (I = 60 μA) and a DC magnetic field (B = 3 μT), this SQIF can detect a magnetic field of a few picoteslas at a frequency of 1.125 GHz, which corresponds to a sensitivity of a few hundreds of fT/Hz and shows a linear response over 7 decades in RF power. This work is a promising approach for the realization of low dissipative subwavelength gigahertz magnetometers.
We have fabricated a YBa2Cu3O7 (YBCO) thin-film dc superconducting quantum interference device (SQUID) with lithographically defined deep-submicron weak links. At 77 K the voltage response to dc flux is sinusoidal and nonhysteretic, with maximum peak-to-peak amplitude of 5 μV. The maximum response is 8 μV at 70 K, where 2LI0/Φ0≊1. At lower temperatures, the maximum response oscillates in the range 4–6 μV. Random telegraph noise was observed near 30–40 K. Well-behaved Shapiro steps were observable at all measured temperatures below Tc.
We present a new superconducting quantum interference device (SQUID) that combines ultra-low-noise performance with tight coupling to a useable input coil. The inductive loop of the SQUID consists of a superconducting square washer that is slit in a low inductance fashion from its central hole to an outside edge where two Josephson tunnel junctions are incorporated. The inductance of the SQUID is about 90 pH, and each junction has a critical current of 15 μA and a resistive shunt of 4.5 Ω. The 190-nH input coil is a planar spiral of 50 turns situated immediately above the washer and coupled to the SQUID with a coupling constant k2 of 0.86. The SQUID has a minimum coupled energy sensitivity of 19h at 4.2 K and 8h at 1.5 K, in good agreement with theory. The crossover between white and low frequency noise occurs at ∼250 Hz.