Physical Review A

SU(1,1) tomography

Giacomo Mauro D’Ariano, Ernesto De Vito, Lorenzo Maccone

Published Aug 13, 2001• 7 citations
Publisher

Abstract

We present a tomographic reconstruction procedure that exploits the symmetry of the SU(1,1) group existing in some physical systems. The tomographic algorithm is derived analytically and the convergence of the procedure is tested on Monte Carlo simulated data.
DOI
10.1103/physreva.64.033805

Related papers

Generalized Orthogonality Relations and SU(1,1)-Quantum Tomography

Claudio Carmeli, Gianni Cassinelli, F. Zizzi

Foundations of Physics•Mar 3, 2009•2 citations

Optimal experiment design for quantum state tomography: Fair, precise, and minimal tomography

J. Nunn, Brian J. Smith, Graciana Puentes +2 more

Given an experimental setup and a fixed number of measurements, how should one take data to optimally reconstruct the state of a quantum system? The problem of optimal experiment design (OED) for quantum state tomography was first broached by Kosut et al. [R. Kosut, I. Walmsley, and H. Rabitz, e-print arXiv:quant-ph/0411093 (2004)]. Here we provide efficient numerical algorithms for finding the optimal design, and analytic results for the case of `minimal tomography'. We also introduce the average OED, which is independent of the state to be reconstructed, and the optimal design for tomography (ODT), which minimizes tomographic bias. Monte Carlo simulations confirm the utility of our results for qubits. Finally, we adapt our approach to deal with constrained techniques such as maximum-likelihood estimation. We find that these are less amenable to optimization than cruder reconstruction methods, such as linear inversion.

arXiv:0911.4310•Physical Review A•Apr 22, 2010•42 citations

Quantum Tomography Via Group Theory

M. Paini

Amongst the multitude of state reconstruction techniques, the so-called "quantum tomography" seems to be the most fruitful. In this letter, I will start by developing the mathematical apparatus of quantum tomography and, later, I will explain how it can be applied to various quantum systems.

arXiv:quant-ph/0002078•Feb 25, 2000•10 citations

Errors in quantum tomography: diagnosing systematic versus statistical errors

Nathan K. Langford

A prime goal of quantum tomography is to provide quantitatively rigorous characterization of quantum systems, be they states, processes or measurements, particularly for the purposes of trouble-shooting and benchmarking experiments in quantum information science. A range of techniques exist to enable the calculation of errors, such as Monte-Carlo simulations, but their quantitative value is arguably fundamentally flawed without an equally rigorous way of authenticating the quality of a reconstruction to ensure it provides a reasonable representation of the data, given the known noise sources. A key motivation for developing such a tool is to enable experimentalists to rigorously diagnose the presence of technical noise in their tomographic data. In this work, I explore the performance of the chi-squared goodness-of-fit test statistic as a measure of reconstruction quality. I show that its behaviour deviates noticeably from expectations for states lying near the boundaries of physical state space, severely undermining its usefulness as a quantitative tool precisely in the region which is of most interest in quantum information processing tasks. I suggest a simple, heuristic approach to compensate for these effects and present numerical simulations showing that this approach provides substantially improved performance.

arXiv:1212.2982•New Journal of Physics•Mar 1, 2013•28 citations

Tomographic representation of spin and quark states

A. B. Klimov, Olga V Man apos ko, Vladimir I Man ko +2 more

We present a short review of the general principles of constructing tomograms of quantum states. We derive a general tomographic reconstruction formula for the quantum density operator of a system with a dynamical Lie group. In the reconstruction formula, the multiplicity of irreducible representation in Clebsch–Gordan decomposition is taken into account. Various approaches to spin tomography are discussed. An integral representation for the tomographic probability is found and a contraction of the spin tomogram to the photon-number tomography distribution is considered. The case of SU (3) tomography is discussed with the examples of quark states (related to the simplest triplet representations) and octet states.

Journal of Physics A Mathematical and General•Jul 12, 2002•50 citations

Reconstruction of Quantum States of Spin Systems: From Quantum Bayesian Inference to Quantum Tomography

Vladimír Bužek, R. Derka, G. Adam +1 more

Annals of Physics•Jul 1, 1998•73 citations
Given an experimental setup and a fixed number of measurements, how should one take data to optimally reconstruct the state of a quantum system? The problem of optimal experiment design (OED) for quantum state tomography was first broached by Kosut et al. [R. Kosut, I. Walmsley, and H. Rabitz, e-print arXiv:quant-ph/0411093 (2004)]. Here we provide efficient numerical algorithms for finding the optimal design, and analytic results for the case of `minimal tomography'. We also introduce the average OED, which is independent of the state to be reconstructed, and the optimal design for tomography (ODT), which minimizes tomographic bias. Monte Carlo simulations confirm the utility of our results for qubits. Finally, we adapt our approach to deal with constrained techniques such as maximum-likelihood estimation. We find that these are less amenable to optimization than cruder reconstruction methods, such as linear inversion.
A prime goal of quantum tomography is to provide quantitatively rigorous characterization of quantum systems, be they states, processes or measurements, particularly for the purposes of trouble-shooting and benchmarking experiments in quantum information science. A range of techniques exist to enable the calculation of errors, such as Monte-Carlo simulations, but their quantitative value is arguably fundamentally flawed without an equally rigorous way of authenticating the quality of a reconstruction to ensure it provides a reasonable representation of the data, given the known noise sources. A key motivation for developing such a tool is to enable experimentalists to rigorously diagnose the presence of technical noise in their tomographic data. In this work, I explore the performance of the chi-squared goodness-of-fit test statistic as a measure of reconstruction quality. I show that its behaviour deviates noticeably from expectations for states lying near the boundaries of physical state space, severely undermining its usefulness as a quantitative tool precisely in the region which is of most interest in quantum information processing tasks. I suggest a simple, heuristic approach to compensate for these effects and present numerical simulations showing that this approach provides substantially improved performance.
We present a short review of the general principles of constructing tomograms of quantum states. We derive a general tomographic reconstruction formula for the quantum density operator of a system with a dynamical Lie group. In the reconstruction formula, the multiplicity of irreducible representation in Clebsch–Gordan decomposition is taken into account. Various approaches to spin tomography are discussed. An integral representation for the tomographic probability is found and a contraction of the spin tomogram to the photon-number tomography distribution is considered. The case of SU (3) tomography is discussed with the examples of quark states (related to the simplest triplet representations) and octet states.