Physical Review A

Exact Photocount Statistics: Lasers near Threshold

M. Lax, M. Zwanziger

Published Feb 1, 1973• 44 citations
Publisher

Abstract

A previously constructed laser model with quantum (noncommuting) noise sources was shown to lead near threshold to a quantum rotating-wave Van der Pol oscillator. A full dynamical correspondence between quantum and classical random processes allows one to compute the average of any time-ordered, normal-ordered operator function by averaging the associated function of classical random variables. Numerical calculations for the associated classical Van der Pol oscillator of the steady-state distribution, the total intensity fluctuations, and the linewidth versus operating point were amply confirmed experimentally. Measurements (and calculations) of higher than two-time correlations were sparse and contradictory. Photocount distributions, at times short compared to the intensity correlation time, confirm only the steady state of the laser. Photocount distributions at intermediate and longer times are difficult to compute because they involve multitime correlations of high ($\ensuremath{\infty}$) order. By providing an exact solution for photocount distributions and their moments for all times, we expected to stimulate measurements near threshold which would provide an adequate test of the Van der Pol laser model. Comparison of the results reported here with recent photocount experiments of Meltzer, Davis, and Mandel and of Jakeman, Oliver, and Pike provides gratifying agreement and confirmation of our statistical understanding of laser fluctuations near threshold.

DOI
10.1103/physreva.7.750

Related papers

Exact Photocount Distributions for Lasers Near Threshold

M. Lax, M. Zwanziger

Photocount fluctuation problems, treated previously for Gaussian statistics only, or in the limit of short measurement times, have been extended to arbitrary times (compared with the intensity correlation time) and to general Markoffian processes. In particular, we calculate the distribution function of the time-integrated light intensity for a laser operated near threshold.

Physical Review Letters•Apr 27, 1970•20 citations

Dead-time-corrected photocounting distributions for laser radiation*

Barry I. Cantor, Malvin Carl Teich

Exact forward photocounting distributions for a source of optical radiation with arbitrary statistics are obtained in the presence of photodetector dead time. In particular, we examine the counting and pulse-interval distributions that arise from amplitude-stabilized radiation, from chaotic radiation, and from a Van der Pol laser with arbitrary excitation. The exact dead-time-corrected Poisson distribution is graphically compared with a previous approximate result and with the uncorrected Poisson. Plots of the Bose–Einstein distribution clearly indicate the dramatic anti-bunching effects of the dead time in overcoming the inherent bunching of this distribution. A simplified approximate solution is also found. for the Van der Pol laser above threshold; this result is similar to light from an amplitude-stabilized source incident on a photodetector with a gaussian-distributed dead time. Information about photodetector dead-time variation can therefore be obtained either by using an amplitude-stabilized source or by properly choosing system parameters such that irradiance fluctuations are averaged out.

Journal of the Optical Society of America•Jul 1, 1975•67 citations

Third- and Higher-Order Intensity Correlation in Laser Light

Cyrus D. Cantrell, M. Lax, Wallace Arden Smith

We have calculated the third- and higher-order (multitime) cumulants of the intensity of single-mode laser light using the rotating-wave van der Pol (RWVP) model. Our results indicate a distinctly nonexponential time dependence of the cumulants slightly below threshold and an oscillatory time dependence somewhat above threshold. One can interpret this oscillatory behavior as showing that the larger fluctuations above the mean decay more rapidly than those below the mean. Measurements of the third-order intensity cumulants above threshold would be desirable to check for this behavior and to provide a more rigorous test of the RWVP model than the second-order intensity correlation.

Physical Review A•Jan 1, 1973•20 citations

MEASUREMENTS OF PHOTOELECTRIC COUNTING DISTRIBUTIONS FOR A LASER NEAR THRESHOLD

David W. Meltzer, W. Davis, L. Mandeļ

Photoelectric counting probabilities have been measured for a laser operating near the threshold of oscillation, for various values of the pump parameter and various counting time intervals. The results are compared with values derived from the recent calculations of Lax and Zwanziger (based on the rotating-wave van der Pol oscillator model of a laser) and show very good agreement.

Applied Physics Letters•Sep 15, 1970•23 citations

Two-Photon Counting Statistics for Laser and Chaotic Radiation

Malvin Carl Teich, Paul Diament

The relation between the two-quantum photocounting distribution p(n, T) and the intensity fluctuations of the radiation incident on the detector is obtained and compared with the one-quantum results. The actual statistics are evaluated for several cases of interest, including a chaotic source, an amplitude-stabilized wave, and the output of a single-mode laser (Van der Pol oscillator). The two-quantum count rate 〈n〉/T is found to depend on the mean-square intensity of the radiation, in contrast to the one-quantum count rate which is proportional to the mean intensity. The effects of photon correlations in the radiation beam become apparent since the two-quantum distributions manifest a distinctly more positive second derivative than the corresponding one-quantum distributions. Both the low-and the high-count probabilities are therefore increased at the expense of counts near the mean. The quantum-theoretical treatment is found to be equivalent to the semiclassical treatment for density operators possessing a positive-definite weight function in the P-representation. Some possible experiments to verify the theory are discussed and shown to be feasible.

Journal of Applied Physics•Feb 1, 1969•40 citations

Photocount Statistics of Transient Laser Light

Andrzej Zardecki, Jacques Bures, Claude A. Delisle

The transient phase-independent solutions of the laser Fokker-Planck equation are analyzed for a short range of time following the moment of the switching on of the oscillations. The evolution of the laser light in time is then represented as a nonstationary Gaussian random process. On the basis of this fact, the factorial moment generating function of the photocount probability distribution is derived, which accounts automatically for all the finite-counting-time corrections. The time development of the first two moments is compared with the recent results of Arecchi and Degiorgio.

Physical Review A•Sep 1, 1972•2 citations
A previously constructed laser model with quantum (noncommuting) noise sources was shown to lead near threshold to a quantum rotating-wave Van der Pol oscillator. A full dynamical correspondence between quantum and classical random processes allows one to compute the average of any time-ordered, normal-ordered operator function by averaging the associated function of classical random variables. Numerical calculations for the associated classical Van der Pol oscillator of the steady-state distribution, the total intensity fluctuations, and the linewidth versus operating point were amply confirmed experimentally. Measurements (and calculations) of higher than two-time correlations were sparse and contradictory. Photocount distributions, at times short compared to the intensity correlation time, confirm only the steady state of the laser. Photocount distributions at intermediate and longer times are difficult to compute because they involve multitime correlations of high (\ensuremath∞\ensuremath{\infty}\ensuremath∞) order. By providing an exact solution for photocount distributions and their moments for all times, we expected to stimulate measurements near threshold which would provide an adequate test of the Van der Pol laser model. Comparison of the results reported here with recent photocount experiments of Meltzer, Davis, and Mandel and of Jakeman, Oliver, and Pike provides gratifying agreement and confirmation of our statistical understanding of laser fluctuations near threshold.
Exact forward photocounting distributions for a source of optical radiation with arbitrary statistics are obtained in the presence of photodetector dead time. In particular, we examine the counting and pulse-interval distributions that arise from amplitude-stabilized radiation, from chaotic radiation, and from a Van der Pol laser with arbitrary excitation. The exact dead-time-corrected Poisson distribution is graphically compared with a previous approximate result and with the uncorrected Poisson. Plots of the Bose–Einstein distribution clearly indicate the dramatic anti-bunching effects of the dead time in overcoming the inherent bunching of this distribution. A simplified approximate solution is also found. for the Van der Pol laser above threshold; this result is similar to light from an amplitude-stabilized source incident on a photodetector with a gaussian-distributed dead time. Information about photodetector dead-time variation can therefore be obtained either by using an amplitude-stabilized source or by properly choosing system parameters such that irradiance fluctuations are averaged out.
We have calculated the third- and higher-order (multitime) cumulants of the intensity of single-mode laser light using the rotating-wave van der Pol (RWVP) model. Our results indicate a distinctly nonexponential time dependence of the cumulants slightly below threshold and an oscillatory time dependence somewhat above threshold. One can interpret this oscillatory behavior as showing that the larger fluctuations above the mean decay more rapidly than those below the mean. Measurements of the third-order intensity cumulants above threshold would be desirable to check for this behavior and to provide a more rigorous test of the RWVP model than the second-order intensity correlation.
The relation between the two-quantum photocounting distribution p(n, T) and the intensity fluctuations of the radiation incident on the detector is obtained and compared with the one-quantum results. The actual statistics are evaluated for several cases of interest, including a chaotic source, an amplitude-stabilized wave, and the output of a single-mode laser (Van der Pol oscillator). The two-quantum count rate 〈n〉/T is found to depend on the mean-square intensity of the radiation, in contrast to the one-quantum count rate which is proportional to the mean intensity. The effects of photon correlations in the radiation beam become apparent since the two-quantum distributions manifest a distinctly more positive second derivative than the corresponding one-quantum distributions. Both the low-and the high-count probabilities are therefore increased at the expense of counts near the mean. The quantum-theoretical treatment is found to be equivalent to the semiclassical treatment for density operators possessing a positive-definite weight function in the P-representation. Some possible experiments to verify the theory are discussed and shown to be feasible.
The transient phase-independent solutions of the laser Fokker-Planck equation are analyzed for a short range of time following the moment of the switching on of the oscillations. The evolution of the laser light in time is then represented as a nonstationary Gaussian random process. On the basis of this fact, the factorial moment generating function of the photocount probability distribution is derived, which accounts automatically for all the finite-counting-time corrections. The time development of the first two moments is compared with the recent results of Arecchi and Degiorgio.