Review of Scientific Instruments

Compact and freely movable single atom detector

P. Westphal, S. Koch, A. Horn, J. Schmand, H. J. Andrä

Published Feb 1, 1999• 3 citations
Publisher

Abstract

A compact fluorescence detector has been developed which allows to count slow, single Na atoms. By using glass fibers for the exciting and the fluorescence light we obtained free movability of the detector. The detection efficiency has been analyzed and optimized by an extensive investigation of all processes concerning the laser-induced fluorescence, especially the random walk of the atom, saturation effects, and optical pumping. Single atoms are identified by registration of photon bursts which stand out from the Poisson distributed background. An absolute calibration of the detection efficiency has been achieved by a time-resolved fluorescence measurement in combination with a corresponding Monte–Carlo simulation. Atomic fluxes well below 1 atom/s can be determined with an uncertainty of less than ±10%. Assuming a continuous flux of 1 atom/s with 25 m/s typically about 50% of these atoms are counted. The detector is an excellent tool for differential scattering experiments with slow atomic beams.

DOI
10.1063/1.1149592

Related papers

A single-atom detector integrated on an atom chip: fabrication, characterization and application

Dennis Heine, Wolfgang Rohringer, D Fischer +7 more

We describe a robust and reliable fluorescence detector for single atoms that is fully integrated on an atom chip. The detector allows spectrally and spatially selective detection of atoms, reaching a single-atom detection efficiency of 66%. It consists of a tapered lensed single-mode fiber for precise delivery of excitation light and a multi-mode fiber to collect the fluorescence. The fibers are mounted in lithographically defined holding structures on the atom chip. Neutral 87 Rb atoms propagating freely in a magnetic guide are detected and the noise of their fluorescence emission is analyzed. The variance of the photon distribution allows us to determine the number of detected photons per atom and from there the atom detection efficiency. The second-order intensity correlation function of the fluorescence shows near-perfect photon anti-bunching and signs of damped Rabi oscillations. With simple improvements, one can increase the detection efficiency to 95%.

arXiv:1002.1573•New Journal of Physics•Sep 9, 2010•30 citations

Miniature fluorescence detector for single atom observation on a microchip

Akifumi Takamizawa, T. Steinmetz, R. Delhuille +2 more

We explore the feasibility of single atom detection on an atom chip by using a tiny fluorescence detector mounted on the chip. Resonant fluorescence from a trapped ultracold atom will be collected with a miniature aspheric lens and taken out of a vacuum chamber through a fiber. During detection, the atom can be held at the focus of the detector with a dipole trapping beam introduced through the same fiber. We have experimentally determined the optical performance of such a detector, taking into account effects such as stray light from the dipole trapping beam and chromatic aberration. The collection efficiency for isotropically emitted radiation is experimentally obtained to be 2.5%. From this, it is estimated that the fluorescence emitted from a single Rb atom will produce a photon count rate of 4.7x10(4) Hz, which is much larger than the shot noise limited background fluctuations.

Optics Express•Jan 1, 2006•10 citations

Photon-burst method in high-resolution laser spectroscopy

D. A. Lewis, J. F. Tonn, S. L. Kaufman +1 more

The sensitivity of high-resolution fluorescence spectroscopy has been enhanced by the detection of bursts of photons from single atoms crossing a laser beam. A tunable cw laser beam intersected a well-collimated atomic beam at right angles, and the fluorescent light was detected by an ellipsoidal collector and a photomultiplier. The passage of an atom through the beam was identified with a burst of detected photon pulses, which could be differentiated easily from the random background. For increasing burst multiplicity the spectra show improved background suppression and also significant peak narrowing. High-resolution spectra were obtained with as few as 10 atoms/sec crossing the laser beam. Statistical predictions for the case of transit-time limited signals are calculated and compared with results obtained for the Na 5890-\AA{} and Ba 5535-\AA{} transitions.

Physical Review A•Apr 1, 1979•24 citations

Single Atom Detection and Non-Classical Photon Correlations

Dennis Heine

In this thesis a reliable and robust single atom detector is presented, characterised and applied to measure the fluorescence emission of single atoms. The detector consists of a tapered single mode excitation fibre and a multi mode detection fibre, both integrated on an atom chip. Single neutral 87Rb atoms propagating freely in a 1D magnetic guide can be detected with an efficiency of 66% due to highly selective excitation and matched detection region. The detector allows to identify the statistical distribution of the atoms, which, for the current experiments, was proven to be Poissonian. Non-classical correlations in the photon emission from a single atom have been measured, showing a perfect photon anti-bunching. Rabi oscillations of the correlation function have been observed and proven to be in excellent agreement with theoretical expectations. The detector presented here is conceptionally much simpler than comparable integrated detectors employing cavity assisted detection and can be produced by using only commercially available lithographic techniques. With this detector single atom sensitivity is reached without the need for cavity assisted detection or localization of the atoms.

•Jan 1, 2008•0 citations

Simple integrated single-atom detector

Marco Wilzbach, Dennis Heine, S. Groth +4 more

We present a reliable and robust integrated fluorescence detector capable of detecting single atoms. The detector consists of a tapered lensed single-mode fiber for precise delivery of excitation light and a multimode fiber to collect the fluorescence. Both are mounted in lithographically defined SU-8 holding structures on an atom chip. 87Rb atoms propagating freely in a magnetic guide are detected with an efficiency of up to 66%, and a signal-to-noise ratio in excess of 100 is obtained for short integration times.

arXiv:0801.3255•Optics Letters•Jan 23, 2009•32 citations

Integrated atom detector: Single atoms and photon statistics

Dennis Heine, Marco Wilzbach, Thomas Raub +2 more

We demonstrate a robust fiber-optics-based fluorescence detector, fully integrated on an atom chip, which detects single atoms propagating in a guide with 66% efficiency. We characterize the detector performance and the atom flux by analyzing the photon statistics. Near-perfect photon antibunching proves that single atoms are detected, and allows us to study the second-order intensity correlation function of the fluorescence over three orders of magnitude in atomic density.

arXiv:0903.3896•Physical Review A•Feb 27, 2009•20 citations
A compact fluorescence detector has been developed which allows to count slow, single Na atoms. By using glass fibers for the exciting and the fluorescence light we obtained free movability of the detector. The detection efficiency has been analyzed and optimized by an extensive investigation of all processes concerning the laser-induced fluorescence, especially the random walk of the atom, saturation effects, and optical pumping. Single atoms are identified by registration of photon bursts which stand out from the Poisson distributed background. An absolute calibration of the detection efficiency has been achieved by a time-resolved fluorescence measurement in combination with a corresponding Monte–Carlo simulation. Atomic fluxes well below 1 atom/s can be determined with an uncertainty of less than ±10%. Assuming a continuous flux of 1 atom/s with 25 m/s typically about 50% of these atoms are counted. The detector is an excellent tool for differential scattering experiments with slow atomic beams.
We describe a robust and reliable fluorescence detector for single atoms that is fully integrated on an atom chip. The detector allows spectrally and spatially selective detection of atoms, reaching a single-atom detection efficiency of 66%. It consists of a tapered lensed single-mode fiber for precise delivery of excitation light and a multi-mode fiber to collect the fluorescence. The fibers are mounted in lithographically defined holding structures on the atom chip. Neutral 87 Rb atoms propagating freely in a magnetic guide are detected and the noise of their fluorescence emission is analyzed. The variance of the photon distribution allows us to determine the number of detected photons per atom and from there the atom detection efficiency. The second-order intensity correlation function of the fluorescence shows near-perfect photon anti-bunching and signs of damped Rabi oscillations. With simple improvements, one can increase the detection efficiency to 95%.
We explore the feasibility of single atom detection on an atom chip by using a tiny fluorescence detector mounted on the chip. Resonant fluorescence from a trapped ultracold atom will be collected with a miniature aspheric lens and taken out of a vacuum chamber through a fiber. During detection, the atom can be held at the focus of the detector with a dipole trapping beam introduced through the same fiber. We have experimentally determined the optical performance of such a detector, taking into account effects such as stray light from the dipole trapping beam and chromatic aberration. The collection efficiency for isotropically emitted radiation is experimentally obtained to be 2.5%. From this, it is estimated that the fluorescence emitted from a single Rb atom will produce a photon count rate of 4.7x10(4) Hz, which is much larger than the shot noise limited background fluctuations.
The sensitivity of high-resolution fluorescence spectroscopy has been enhanced by the detection of bursts of photons from single atoms crossing a laser beam. A tunable cw laser beam intersected a well-collimated atomic beam at right angles, and the fluorescent light was detected by an ellipsoidal collector and a photomultiplier. The passage of an atom through the beam was identified with a burst of detected photon pulses, which could be differentiated easily from the random background. For increasing burst multiplicity the spectra show improved background suppression and also significant peak narrowing. High-resolution spectra were obtained with as few as 10 atoms/sec crossing the laser beam. Statistical predictions for the case of transit-time limited signals are calculated and compared with results obtained for the Na 5890-\AA{} and Ba 5535-\AA{} transitions.
In this thesis a reliable and robust single atom detector is presented, characterised and applied to measure the fluorescence emission of single atoms. The detector consists of a tapered single mode excitation fibre and a multi mode detection fibre, both integrated on an atom chip. Single neutral 87Rb atoms propagating freely in a 1D magnetic guide can be detected with an efficiency of 66% due to highly selective excitation and matched detection region. The detector allows to identify the statistical distribution of the atoms, which, for the current experiments, was proven to be Poissonian. Non-classical correlations in the photon emission from a single atom have been measured, showing a perfect photon anti-bunching. Rabi oscillations of the correlation function have been observed and proven to be in excellent agreement with theoretical expectations. The detector presented here is conceptionally much simpler than comparable integrated detectors employing cavity assisted detection and can be produced by using only commercially available lithographic techniques. With this detector single atom sensitivity is reached without the need for cavity assisted detection or localization of the atoms.
We present a reliable and robust integrated fluorescence detector capable of detecting single atoms. The detector consists of a tapered lensed single-mode fiber for precise delivery of excitation light and a multimode fiber to collect the fluorescence. Both are mounted in lithographically defined SU-8 holding structures on an atom chip. 87Rb atoms propagating freely in a magnetic guide are detected with an efficiency of up to 66%, and a signal-to-noise ratio in excess of 100 is obtained for short integration times.