Determination of the Parameters Characterizing a Two Lines Spectrum by Measuring n(2)(T): Rectangular Profiles Approximation

M. Á. Rebolledo, Felipe González

Published May 1, 1983• 5 citations
Publisher

Abstract

In the present paper we study the possibility of analyzing a light beam with a spectrum of two lines, by measuring the normalized second order factorial moment of the photon-counting distribution of the light beam. Two lines with rectangular profile are considered in order to simplify calculations and experiments. The error in the determination of width, separation and relative height of lines is studied by means of an experimentally checked theoretical model.

DOI
10.1080/00387018308062353

Related papers

Analysis of a spectrum of two Lorentzian or Gaussian lines by measuring n^(2)(T)

Felipe González, M. Á. Rebolledo, Manuel P. Cagigal

In this paper we study the possibility of analyzing a low intensity light beam whose spectrum has two lines with Lorentzian or Gaussian profiles by measuring n(2)(T) (the normalized second-order factorial moment). To do this the spectrum is scanned periodically by a spectrometer, and the normalized second-order factorial moment of the beam intensity at the exit aperture of the spectrometer is measured. The errors involved in the determination of the width, relative height, and separation between the two lines are calculated and discussed.

Applied Optics•Sep 1, 1984•11 citations

Level-crossing detection through measurement of the second factorial moment of photon-counting distribution

M. Á. Rebolledo, J. J. Sanz

A level-crossing detection method is presented and developed based on measurement of the normalized second factorial moment n((2))(T) of the photon-counting distribution of the resultant fluorescence. Expression n((2))(T) is obtained, and the errors expected in the determination of signal width and crossing field are theoretically studied. The validity of the approximations performed to establish the theoretical model is proved by an experiment with a square-wave periodically modulated light beam.

Applied Optics•Aug 1, 1980•15 citations

Factorial Moment of Two Poissonian Lights Superposed on Gaussian-Lorentzian Light

Hideaki Satō, Norihito Suzuki

A photon counting method is adapted to spectroscopy in very low intensity, as it is useful for data acquisition. There are two Poissonian lights which cannot be discriminated by this method. One is coherent light, and the other is Gaussian-Lorentzian light with infinite spectral linewidth. In this experiment, Gaussian-Lorentzian light with finite spectral linewidth was superposed on each Poissonian light, and the difference of the two radiation mechanisms was determined by profiles of the second-order factorial moment of the photon counting distribution.

Japanese Journal of Applied Physics•Jun 1, 1981•0 citations

Analysis of a periodically modulated light beam by measurement of the moment-generating function of the number of photopulses

Felipe González, Fernando G. Moreno

We analyze a low-intensity square-wave modulated light signal by measuring the moment-generating function of the number of photopulses, Qn(s, T). The behavior of the experimental errors in the determination of the period and the modulation factor of the signal is studied by means of a theoretical error model. A set of experimental measurements was carried out, and the results found through the Qn(s, T) measurement and by the normalized second-order factorial moment n(2)(T) are compared.

Journal of the Optical Society of America B•Oct 1, 1992•1 citation

Photon Counting Statistics of Thermal Light Consisting of Two Spectral Lines

N. Tornau, B. Echtermeyer

Abstract The generating function for the photon counting distribution is calculated for polarized thermal light in the case that the spectral profile of the light is a superposition of two LORENTZian lines with the same central frequency but different halfwidth at half height. Further we present results for the moments of the counting distribution in this case and also for a frequency separation of both line‐centers.

Annalen der Physik•Jan 1, 1973•6 citations

Analysis of a light beam with a periodically modulated intensity by triggered photon counting

M. Á. Rebolledo, J. M. Alvarez, Julio Cesar Amare

Theoretical expressions for the factorial moments of the triggered photon-counting distribution that corresponds to a light beam with a periodically modulated intensity are derived. Two triggering procedures are considered: the time-window triggering procedure (which has been experimentally checked for Gaussian light by other authors) and the first-photopulse triggering procedure (which is a faster procedure). The theoretical expressions that correspond to the latter procedure are experimentally checked in this paper by using a square-wave signal. The errors involved in the analysis of the information contained in the light beam, when this information is obtained from the measurement of the first-order factorial moment, are studied.

Journal of the Optical Society of America A•Jan 1, 1986•6 citations
In the present paper we study the possibility of analyzing a light beam with a spectrum of two lines, by measuring the normalized second order factorial moment of the photon-counting distribution of the light beam. Two lines with rectangular profile are considered in order to simplify calculations and experiments. The error in the determination of width, separation and relative height of lines is studied by means of an experimentally checked theoretical model.
In this paper we study the possibility of analyzing a low intensity light beam whose spectrum has two lines with Lorentzian or Gaussian profiles by measuring n(2)(T) (the normalized second-order factorial moment). To do this the spectrum is scanned periodically by a spectrometer, and the normalized second-order factorial moment of the beam intensity at the exit aperture of the spectrometer is measured. The errors involved in the determination of the width, relative height, and separation between the two lines are calculated and discussed.
A level-crossing detection method is presented and developed based on measurement of the normalized second factorial moment n((2))(T) of the photon-counting distribution of the resultant fluorescence. Expression n((2))(T) is obtained, and the errors expected in the determination of signal width and crossing field are theoretically studied. The validity of the approximations performed to establish the theoretical model is proved by an experiment with a square-wave periodically modulated light beam.
A photon counting method is adapted to spectroscopy in very low intensity, as it is useful for data acquisition. There are two Poissonian lights which cannot be discriminated by this method. One is coherent light, and the other is Gaussian-Lorentzian light with infinite spectral linewidth. In this experiment, Gaussian-Lorentzian light with finite spectral linewidth was superposed on each Poissonian light, and the difference of the two radiation mechanisms was determined by profiles of the second-order factorial moment of the photon counting distribution.
Theoretical expressions for the factorial moments of the triggered photon-counting distribution that corresponds to a light beam with a periodically modulated intensity are derived. Two triggering procedures are considered: the time-window triggering procedure (which has been experimentally checked for Gaussian light by other authors) and the first-photopulse triggering procedure (which is a faster procedure). The theoretical expressions that correspond to the latter procedure are experimentally checked in this paper by using a square-wave signal. The errors involved in the analysis of the information contained in the light beam, when this information is obtained from the measurement of the first-order factorial moment, are studied.