Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

AIP conference proceedings

Multiplexing of Hot-Electron Nanobolometers Using Microwave SQUIDs

Boris S. Karasik, Peter K. Day, Jonathan H. Kawamura, B. Bumble, Henry George LeDuc, Betty Young, Blas Cabrera, Aaron Miller

Published Jan 1, 2009• 3 citations
Publisher

Abstract

We have obtained the first data on the multiplexed operation of titanium hot‐electron bolometers (HEB). Because of their low thermal conductance and small electron heat capacity nanobolometers are particularly interesting as sensors for far‐infrared spectroscopy and mid‐ and near‐IR calorimetry. However, the short time constant of these devices (∼μs at 300–400 mK) makes time domain or audio‐frequency domain multiplexing impractical. The Microwave SQUID (MSQUID) approach pursued in this work uses dc SQUIDs coupled to X‐band microresonators which are, in turn, coupled to a transmission line. We used a 4‐element array of Ti HEBs operated at 415 mK in a He3 dewar with an optical fiber access. The microwave signal exhibited 10‐MHz wide resonances at individual MSQUD frequencies between 9 GHz and 10 GHz. The resonance depth is modulated by the current through the bolometer via a change of the SQUID flux state. The transmitted signal was amplified by a cryogenic amplifier and downconverted to baseband using an IQ mixer. A 1‐dB per Ω0/2 responsivity was sufficient for keeping the system noise at the level of ∼2 pA/Hz1/2. This is more than an order of magnitude smaller than phonon noise in the HEB. The devices were able to detect single near‐IR photons (1550 nm) with a time constant of 3.5 μs. Follow‐on work will scale the array to larger size and will address the microwave frequency signal generation and processing using a digital transceiver.

DOI
10.1063/1.3292327

Related papers

Demonstration of Multiplexed Operation of Hot-Electron Detectors Using MSQUIDs

Boris S. Karasik, Peter K. Day, Jonathan H. Kawamura +4 more

We have demonstrated the multiplexed operation of titanium hot-electron nanobolometers (nano-HEB). Because of their low thermal conductance and small electron heat capacity nanobolometers are particularly interesting as sensors for far- infrared spectroscopy and mid- and near-IR calorimetry. However, the short time constant of these devices (~ µs at 300- 400 mK) makes time domain or audio-frequency domain multiplexing impractical. The Microwave SQUID (MSQUID) approach pursued in this work uses dc SQUIDs coupled to GHz-band microresonators which are, in turn, coupled to a transmission line. We used a 4-element array of Ti HEBs operated at 415 mK in a He3 dewar with an optical fiber access. The microwave signal exhibited 10-MHz wide resonances at individual MSQUD frequencies between 9 GHz and 10 GHz. The resonance depth is modulated by the current through the bolometer via a change of the SQUID flux state. The transmitted signal was amplified by a cryogenic amplifier and downconverted to baseband using an IQ mixer. A 1-dB per Φ 0 /2 responsivity was sufficient for keeping the system noise at the level of ~ 2 pA/Hz 1/2 . This is more than an order of magnitude smaller than phonon noise in the HEB. The devices were able to detect single near-IR photons (1550 nm) with a time constant of 3.5 µs. A digital transceiver for simultaneous generation of 16 probing tones and for processing of 16 downconverting signals has been demonstrated as well.

•Mar 1, 2010•1 citation

Superconducting hot electron bolometers for terahertz sensing

Matthew O. Reese

Superconducting Hot Electron Bolometers (HEBs) are good candidates for detecting weak signals in the submillimeter or terahertz range. In this thesis work, a novel fabrication method was developed to make two types of niobium HEBs for different applications. HEBs were designed, fabricated, and then characterized at dc, microwave, and THz frequencies. The first type is a diffusion-cooled HEB, made with a short bridge that determines its cooling time. In this thesis, bridges were typically 400 nm long with bandwidths of about 1 GHz. These diffusion-cooled HEBs were developed as part of a collaboration with the University of Arizona (UA), to develop a proof-of-concept heterodyne array submillimeter camera. Devices were fabricated on thin fused quartz and silica substrates for waveguide coupling in the UA system for the astrophysically interesting 345 and 810 GHz atmospheric windows. The goal of this collaboration is to provide a basis of comparison between Nb diffusion-cooled HEB mixers and superconductorinsulator-superconductor mixers at these frequencies. The second type is a phonon-cooled HEB, made with a ∼3 µm long bridge. Its thermal response is dictated by the electron-phonon relaxation time. These devices were developed in collaboration with Prof. C. Schmuttenmaer’s lab in the Yale Chemistry department, Prof. G. Blake at Caltech,

•Jan 1, 2006•7 citations

Nearly Quantum Limited Two-Stage SQUID Amplifiers for the Frequency Domain Multiplexing of TES Based X-ray and Infrared Detectors

Luciano G. Gottardi, M. Kiviranta, Jan van der Kuur +3 more

The frequency domain multiplexing (FDM) readout of arrays of transition edges sensors for the X-IFU/Athena and SAFARI/SPICA instruments requires SQUID amplifiers with low input inductance, low flux noise, high-dynamic range and low power consumption. We report the performance of two-stage SQUID amplifiers developed at VTT coupled to multiple high-Q LC resonators of the SRON FDM readout operating in the frequency range from 2 to 5 MHz. The SQUIDs have been tested in the following configurations: 1) the two SQUIDs at base temperature with open input; 2) the amplifier SQUID at 1K temperature and the front-end SQUID at base temperature in the FDM readout of low-G TES bolometers; and 3) and in the FDM readout of X-ray microcalorimeter arrays with both SQUIDS at base temperature. We measured an input flux noise equal to 0.18 μΦ0/Hz1/2at 20 mK, equivalent to an energy resolution of 9 b. The measured current noise at the SQUID input is ~1 pA/Hz1/2at 20 mK, which corresponds to a coupled energy resolution of about 15 b.

IEEE Transactions on Applied Superconductivity•Nov 10, 2014•15 citations

Record-Low NEP in Hot-Electron Titanium Nanobolometers

Boris S. Karasik, David I. Olaya, Jian Wei +5 more

We are developing hot-electron superconducting transition-edge sensors (TES) capable of counting THz photons and operating at . We fabricated superconducting Ti nanosensors with Nb contacts with a volume of on planar Si substrates and have measured the thermal conductance in the material, G=4times10-3W/K at 0.3 K, caused predominantly by the weak electron-phonon coupling. The corresponding phonon-noise NEP=3times10-19W/Hz1/2. Detection of single optical photons (1550 nm and 670 nm wavelength) has been demonstrated for larger devices and yielded the thermal time constants of 30 mus at 145 mK and of 25 mus at 190 mK. This hot-electron direct detector (HEDD) is expected to have a small enough energy fluctuation noise for detecting individual photons with v>THz where NEP~3times10-20W/Hz1/2is needed for spectroscopy in space.

IEEE Transactions on Applied Superconductivity•Jun 1, 2007•40 citations

Demonstration of high optical sensitivity in far-infrared hot-electron bolometer

Boris S. Karasik, R. Cantor

We report on the measurement of a very low noise equivalent power of 3×10−19 W/Hz1/2 at 620 GHz in a superconducting antenna-coupled hot-electron bolometer. The sensing element is a micron-size titanium transition-edge sensor with NbTiN superconducting contacts fabricated on a sapphire substrate. The high sensitivity is due to the small device volume, low operating temperature, and weak electron-phonon coupling in titanium film. Measurements were done using a cryogenic black body emitter producing well-controlled femtowatt power levels. The achieved optical sensitivity is suitable for the low-background spectroscopy of molecular lines on next generation space telescopes.

Applied Physics Letters•May 9, 2011•59 citations

An X-band SQUID Multiplexer

Inseob Hahn, Bruce Bumble, Henry George LeDuc +2 more

We are developing a microwave readout multiplexer for arrays of superconducting quantum interference devices (SQUIDs). A series of microwave resonators with frequencies ∼10 GHz are each loaded by a dc SQUID to a degree that depends on the flux state of the SQUID. By using resonators with high quality factors and slightly different resonance frequencies, many of these resonator‐coupled SQUIDs may be read out with a single excitation line and cryogenic amplifier. Our multiplexer is similar to the one demonstrated by Irwin and Lehnert except for the use of higher‐frequency, fully‐lithographed transmission line resonators. We discuss a technique for modulating the SQUID array in series that alleviates the need to individually flux‐bias the SQUIDs. The multiplexer has applications to the readout of detector arrays for astronomy as well as medical magnetic imaging.

AIP conference proceedings•Jan 1, 2006•4 citations
We have obtained the first data on the multiplexed operation of titanium hot‐electron bolometers (HEB). Because of their low thermal conductance and small electron heat capacity nanobolometers are particularly interesting as sensors for far‐infrared spectroscopy and mid‐ and near‐IR calorimetry. However, the short time constant of these devices (∼μs at 300–400 mK) makes time domain or audio‐frequency domain multiplexing impractical. The Microwave SQUID (MSQUID) approach pursued in this work uses dc SQUIDs coupled to X‐band microresonators which are, in turn, coupled to a transmission line. We used a 4‐element array of Ti HEBs operated at 415 mK in a He3 dewar with an optical fiber access. The microwave signal exhibited 10‐MHz wide resonances at individual MSQUD frequencies between 9 GHz and 10 GHz. The resonance depth is modulated by the current through the bolometer via a change of the SQUID flux state. The transmitted signal was amplified by a cryogenic amplifier and downconverted to baseband using an IQ mixer. A 1‐dB per Ω0/2 responsivity was sufficient for keeping the system noise at the level of ∼2 pA/Hz1/2. This is more than an order of magnitude smaller than phonon noise in the HEB. The devices were able to detect single near‐IR photons (1550 nm) with a time constant of 3.5 μs. Follow‐on work will scale the array to larger size and will address the microwave frequency signal generation and processing using a digital transceiver.
We have demonstrated the multiplexed operation of titanium hot-electron nanobolometers (nano-HEB). Because of their low thermal conductance and small electron heat capacity nanobolometers are particularly interesting as sensors for far- infrared spectroscopy and mid- and near-IR calorimetry. However, the short time constant of these devices (~ µs at 300- 400 mK) makes time domain or audio-frequency domain multiplexing impractical. The Microwave SQUID (MSQUID) approach pursued in this work uses dc SQUIDs coupled to GHz-band microresonators which are, in turn, coupled to a transmission line. We used a 4-element array of Ti HEBs operated at 415 mK in a He3 dewar with an optical fiber access. The microwave signal exhibited 10-MHz wide resonances at individual MSQUD frequencies between 9 GHz and 10 GHz. The resonance depth is modulated by the current through the bolometer via a change of the SQUID flux state. The transmitted signal was amplified by a cryogenic amplifier and downconverted to baseband using an IQ mixer. A 1-dB per Φ 0 /2 responsivity was sufficient for keeping the system noise at the level of ~ 2 pA/Hz 1/2 . This is more than an order of magnitude smaller than phonon noise in the HEB. The devices were able to detect single near-IR photons (1550 nm) with a time constant of 3.5 µs. A digital transceiver for simultaneous generation of 16 probing tones and for processing of 16 downconverting signals has been demonstrated as well.
Superconducting Hot Electron Bolometers (HEBs) are good candidates for detecting weak signals in the submillimeter or terahertz range. In this thesis work, a novel fabrication method was developed to make two types of niobium HEBs for different applications. HEBs were designed, fabricated, and then characterized at dc, microwave, and THz frequencies. The first type is a diffusion-cooled HEB, made with a short bridge that determines its cooling time. In this thesis, bridges were typically 400 nm long with bandwidths of about 1 GHz. These diffusion-cooled HEBs were developed as part of a collaboration with the University of Arizona (UA), to develop a proof-of-concept heterodyne array submillimeter camera. Devices were fabricated on thin fused quartz and silica substrates for waveguide coupling in the UA system for the astrophysically interesting 345 and 810 GHz atmospheric windows. The goal of this collaboration is to provide a basis of comparison between Nb diffusion-cooled HEB mixers and superconductorinsulator-superconductor mixers at these frequencies. The second type is a phonon-cooled HEB, made with a ∼3 µm long bridge. Its thermal response is dictated by the electron-phonon relaxation time. These devices were developed in collaboration with Prof. C. Schmuttenmaer’s lab in the Yale Chemistry department, Prof. G. Blake at Caltech,
The frequency domain multiplexing (FDM) readout of arrays of transition edges sensors for the X-IFU/Athena and SAFARI/SPICA instruments requires SQUID amplifiers with low input inductance, low flux noise, high-dynamic range and low power consumption. We report the performance of two-stage SQUID amplifiers developed at VTT coupled to multiple high-Q LC resonators of the SRON FDM readout operating in the frequency range from 2 to 5 MHz. The SQUIDs have been tested in the following configurations: 1) the two SQUIDs at base temperature with open input; 2) the amplifier SQUID at 1K temperature and the front-end SQUID at base temperature in the FDM readout of low-G TES bolometers; and 3) and in the FDM readout of X-ray microcalorimeter arrays with both SQUIDS at base temperature. We measured an input flux noise equal to 0.18 μΦ0/Hz1/2at 20 mK, equivalent to an energy resolution of 9 b. The measured current noise at the SQUID input is ~1 pA/Hz1/2at 20 mK, which corresponds to a coupled energy resolution of about 15 b.
We are developing hot-electron superconducting transition-edge sensors (TES) capable of counting THz photons and operating at . We fabricated superconducting Ti nanosensors with Nb contacts with a volume of on planar Si substrates and have measured the thermal conductance in the material, G=4times10-3W/K at 0.3 K, caused predominantly by the weak electron-phonon coupling. The corresponding phonon-noise NEP=3times10-19W/Hz1/2. Detection of single optical photons (1550 nm and 670 nm wavelength) has been demonstrated for larger devices and yielded the thermal time constants of 30 mus at 145 mK and of 25 mus at 190 mK. This hot-electron direct detector (HEDD) is expected to have a small enough energy fluctuation noise for detecting individual photons with v>THz where NEP~3times10-20W/Hz1/2is needed for spectroscopy in space.
We report on the measurement of a very low noise equivalent power of 3×10−19 W/Hz1/2 at 620 GHz in a superconducting antenna-coupled hot-electron bolometer. The sensing element is a micron-size titanium transition-edge sensor with NbTiN superconducting contacts fabricated on a sapphire substrate. The high sensitivity is due to the small device volume, low operating temperature, and weak electron-phonon coupling in titanium film. Measurements were done using a cryogenic black body emitter producing well-controlled femtowatt power levels. The achieved optical sensitivity is suitable for the low-background spectroscopy of molecular lines on next generation space telescopes.
We are developing a microwave readout multiplexer for arrays of superconducting quantum interference devices (SQUIDs). A series of microwave resonators with frequencies ∼10 GHz are each loaded by a dc SQUID to a degree that depends on the flux state of the SQUID. By using resonators with high quality factors and slightly different resonance frequencies, many of these resonator‐coupled SQUIDs may be read out with a single excitation line and cryogenic amplifier. Our multiplexer is similar to the one demonstrated by Irwin and Lehnert except for the use of higher‐frequency, fully‐lithographed transmission line resonators. We discuss a technique for modulating the SQUID array in series that alleviates the need to individually flux‐bias the SQUIDs. The multiplexer has applications to the readout of detector arrays for astronomy as well as medical magnetic imaging.