Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Proceedings of the National Academy of Sciences

Continuous Stern-Gerlach effect: Principle and idealized apparatus

HANS G. DEHMELT

Published Apr 1, 1986• 115 citations
Publisher

Abstract

A nondestructive type of Stern-Gerlach effect for an individual electron is described that has been thoroughly demonstrated in experiments at the University of Washington. This "continuous Stern-Gerlach effect" makes use of an inhomogeneous magnetic field provided by a weak auxiliary magnetic bottle and is nondestructive in contrast to all previous versions of the effect. As in the classic Stern-Gerlach effect, changes in the spin state are detected via changes in classical particle trajectories; however, what is observed now is not a deflection of the orbit but rather a change of its frequency in the storage well. A simplified model of the continuous Stern-Gerlach effect at zero temperature is introduced to develop the relation between minimum measurement time required for determination of spin state, driven oscillation amplitude, and zero-point fluctuations in the storage well. The problem of the reduction of the wavefunction by the interaction of the electron with the apparatus is addressed following W. Pauli.

DOI
10.1073/pnas.83.8.2291

Related papers

Continuous Stern-Gerlach effect: Principle and idealized apparatus (trapped single electron/aidal oscillation frequency/spin-dependent classical trajectories/reduction of wavefunction/measurement time)

HANS G. DEHMELT

A nondestructive type of Stern-Gerlach ef- fect for an individual electron is described that has been thoroughly demonstrated in experiments at the University of Washington. This Stern-Gerlach makes use of an inhomogeneous magnetic field provided by a weak auxiliary magnetic bottle and is nondestructive in contrast to all previous versions of the effect. As in the classic Stern-Gerlach effect, changes in the spin state are detected via changes in classical particle trajectories; however, what is observed now is not a deflection of the orbit but rather a change of its frequency in the storage well. A simplified model of the continuous Stern-Gerlach effect at zero temperature is introduced to develop the relation between minimum measurement time required for determination of spin state, driven oscillation amplitude, and zero-point fluctuations in the storage well. The problem of the reduction of the wavefunction by the interaction of the electron with the apparatus is addressed following W. Pauli.

•Jan 1, 2017•0 citations

Continuous Stern-Gerlach effect: Noise and the measurement process

HANS G. DEHMELT

This paper resumes the discussion of the continuous Stern-Gerlach effect, a method to continuously and nondestructively determine the spin state of the same individual electron, quasipermanently confined in a Penning trap in ultrahigh vacuum at liquid helium temperatures. Here the focus is on limitations to spin-state detection due to thermal and zero-point noise and on the quantum-mechanical measurement process. Illustrations of the continuous spin measurement process in the presence of selected perturbations are provided. The alteration of the spin state brought about by the frequency measurement process is exhibited. To resolve Zeno's paradox in a specific example, a slow resonant spin flip is discussed, when interrupted by frequent spin-state measurements. The continuous Stern-Gerlach effect is shown to be a near-ideal example for the quantum mechanical measurement process, for which all steps may be followed in quantitative detail.

Proceedings of the National Academy of Sciences•May 1, 1986•18 citations

The Stern–Gerlach experiment and the effects of spin relaxation

Håkan Wennerström, Per-Olof Westlund

The classical Stern-Gerlach experiment is analyzed with an emphasis on the spin dynamics. The central question asked is whether there occurs a relaxation of the spin angular momentum during the time the particle passes through the Stern-Gerlach magnet. We examine in particular the transverse relaxation, involving angular momentum exchange between the spin of the particles and the spins of the magnet. A method is presented describing relaxation effects at an individual particle level. This leads to a stochastic equation of motion for the spins. This is coupled to a classical equation of motion for the particle translation. The experimental situation is then modeled through simulations of individual trajectories using two sets of parameter choices and three different sets of initial conditions. The two main conclusions are: (A) if the coupling between the magnet and the spin is solely described by the Zeeman interaction with the average magnetic field the simulations show a clear disagreement with the experimental observation of Stern and Gerlach. (B) If one, on the other hand, also allows for a T(2) relaxation time shorter than the passage time one can obtain a practically quantitative agreement with the experimental observations. These conclusions are at variance with the standard textbook explanation of the Stern-Gerlach experiment.

Physical Chemistry Chemical Physics•Dec 23, 2011•18 citations

Stern-Gerlach Effect for Electron Beams

Herman Batelaan, T. J. Gay, J. J. Schwendiman

The conflict between Bohr's assertion that the magnetic moment of the electron cannot be measured with experiments based on the concept of classical trajectories, and the measurement of the magnetic moment of electrons in a modified Penning trap by Dehmelt et al. has led us to reevaluate other implications of Bohr's assertion. We show that, contrary to the analysis of Bohr and Pauli, the assumption of classical trajectories in a Stern-Gerlach--like device can result in a high degree of spin separation for an electron beam. This effect may persist within a fully quantum-mechanical analysis. The magnetic fields considered are such that a tabletop Stern-Gerlach electron spin filter is feasible.

Physical Review Letters•Dec 8, 1997•84 citations

Electric-type Stern–Gerlach effect

Jun Zhou, Zitao Fu, C. H. Oh +1 more

Abstract The Stern–Gerlach (SG) experiment is a fundamental experiment for revealing the existence of “spin”. In this experiment, beams of silver atoms are sent through inhomogeneous magnetic fields to observe their deflection. Thus, the conventional SG experiment can be viewed as a magnetic-type spin effect. In this work, we successfully generalize the SG effect from magnetic-type to electric-type by solving Dirac’s equation with a potential barrier, revealing an extraordinary spin effect. Beams of Dirac particles can be regarded as matter waves. Based on Dirac’s equation, we obtain the explicit forms of the incident, reflected, and transmitted waves. The electric-type SG effect shows that the reflected and transmitted waves can exhibit notable spatial shifts, which depend on the spin direction and the incident angle of the wave. The electric-type SG effect has potential applications for separating Dirac particles with different spin directions and for estimating the spin direction of Dirac particles. Some discussions related to the interaction between spin and the electric field are also presented.

arXiv:2501.04380•Chinese Physics B•Oct 9, 2025•0 citations

Reduction of the atomic wavefunction in the Stern–Gerlach magnetic field

Michael Devereux

Observation of two separated beam spots at a detection screen downstream of a Stern–Gerlach magnet does not, in fact, demonstrate that the wavefunction of a neutral spin one-half particle has remained in a spin superposition while traveling through that magnetic field. The wavefunction may have been reduced to just one spin-direction eigenfunction, as D. Bohm suggested, by immediate momentum and energy transfer with the magnet, rather than by subsequent, which-way determination at the screen. The same two beam spots at the detector screen will result. Einsteinian relativity, and the understanding of Schrödinger evolution applicability through a static potential, forbid continuation of a spin superposition through the Stern–Gerlach field. A calculation for single wavepacket development there conforms to observations from the Stern–Gerlach experiment. And several experiments corroborate immediate reduction to a single spin eigenfunction in the magnetic field. Additionally, Ramsey’s separated, oscillating fields observations, and related experiments, do not rebut this understanding.

Canadian Journal of Physics•Jun 1, 2015•19 citations
A nondestructive type of Stern-Gerlach effect for an individual electron is described that has been thoroughly demonstrated in experiments at the University of Washington. This "continuous Stern-Gerlach effect" makes use of an inhomogeneous magnetic field provided by a weak auxiliary magnetic bottle and is nondestructive in contrast to all previous versions of the effect. As in the classic Stern-Gerlach effect, changes in the spin state are detected via changes in classical particle trajectories; however, what is observed now is not a deflection of the orbit but rather a change of its frequency in the storage well. A simplified model of the continuous Stern-Gerlach effect at zero temperature is introduced to develop the relation between minimum measurement time required for determination of spin state, driven oscillation amplitude, and zero-point fluctuations in the storage well. The problem of the reduction of the wavefunction by the interaction of the electron with the apparatus is addressed following W. Pauli.
A nondestructive type of Stern-Gerlach ef- fect for an individual electron is described that has been thoroughly demonstrated in experiments at the University of Washington. This Stern-Gerlach makes use of an inhomogeneous magnetic field provided by a weak auxiliary magnetic bottle and is nondestructive in contrast to all previous versions of the effect. As in the classic Stern-Gerlach effect, changes in the spin state are detected via changes in classical particle trajectories; however, what is observed now is not a deflection of the orbit but rather a change of its frequency in the storage well. A simplified model of the continuous Stern-Gerlach effect at zero temperature is introduced to develop the relation between minimum measurement time required for determination of spin state, driven oscillation amplitude, and zero-point fluctuations in the storage well. The problem of the reduction of the wavefunction by the interaction of the electron with the apparatus is addressed following W. Pauli.
This paper resumes the discussion of the continuous Stern-Gerlach effect, a method to continuously and nondestructively determine the spin state of the same individual electron, quasipermanently confined in a Penning trap in ultrahigh vacuum at liquid helium temperatures. Here the focus is on limitations to spin-state detection due to thermal and zero-point noise and on the quantum-mechanical measurement process. Illustrations of the continuous spin measurement process in the presence of selected perturbations are provided. The alteration of the spin state brought about by the frequency measurement process is exhibited. To resolve Zeno's paradox in a specific example, a slow resonant spin flip is discussed, when interrupted by frequent spin-state measurements. The continuous Stern-Gerlach effect is shown to be a near-ideal example for the quantum mechanical measurement process, for which all steps may be followed in quantitative detail.
The classical Stern-Gerlach experiment is analyzed with an emphasis on the spin dynamics. The central question asked is whether there occurs a relaxation of the spin angular momentum during the time the particle passes through the Stern-Gerlach magnet. We examine in particular the transverse relaxation, involving angular momentum exchange between the spin of the particles and the spins of the magnet. A method is presented describing relaxation effects at an individual particle level. This leads to a stochastic equation of motion for the spins. This is coupled to a classical equation of motion for the particle translation. The experimental situation is then modeled through simulations of individual trajectories using two sets of parameter choices and three different sets of initial conditions. The two main conclusions are: (A) if the coupling between the magnet and the spin is solely described by the Zeeman interaction with the average magnetic field the simulations show a clear disagreement with the experimental observation of Stern and Gerlach. (B) If one, on the other hand, also allows for a T(2) relaxation time shorter than the passage time one can obtain a practically quantitative agreement with the experimental observations. These conclusions are at variance with the standard textbook explanation of the Stern-Gerlach experiment.
The conflict between Bohr's assertion that the magnetic moment of the electron cannot be measured with experiments based on the concept of classical trajectories, and the measurement of the magnetic moment of electrons in a modified Penning trap by Dehmelt et al. has led us to reevaluate other implications of Bohr's assertion. We show that, contrary to the analysis of Bohr and Pauli, the assumption of classical trajectories in a Stern-Gerlach--like device can result in a high degree of spin separation for an electron beam. This effect may persist within a fully quantum-mechanical analysis. The magnetic fields considered are such that a tabletop Stern-Gerlach electron spin filter is feasible.
Abstract The Stern–Gerlach (SG) experiment is a fundamental experiment for revealing the existence of “spin”. In this experiment, beams of silver atoms are sent through inhomogeneous magnetic fields to observe their deflection. Thus, the conventional SG experiment can be viewed as a magnetic-type spin effect. In this work, we successfully generalize the SG effect from magnetic-type to electric-type by solving Dirac’s equation with a potential barrier, revealing an extraordinary spin effect. Beams of Dirac particles can be regarded as matter waves. Based on Dirac’s equation, we obtain the explicit forms of the incident, reflected, and transmitted waves. The electric-type SG effect shows that the reflected and transmitted waves can exhibit notable spatial shifts, which depend on the spin direction and the incident angle of the wave. The electric-type SG effect has potential applications for separating Dirac particles with different spin directions and for estimating the spin direction of Dirac particles. Some discussions related to the interaction between spin and the electric field are also presented.
Observation of two separated beam spots at a detection screen downstream of a Stern–Gerlach magnet does not, in fact, demonstrate that the wavefunction of a neutral spin one-half particle has remained in a spin superposition while traveling through that magnetic field. The wavefunction may have been reduced to just one spin-direction eigenfunction, as D. Bohm suggested, by immediate momentum and energy transfer with the magnet, rather than by subsequent, which-way determination at the screen. The same two beam spots at the detector screen will result. Einsteinian relativity, and the understanding of Schrödinger evolution applicability through a static potential, forbid continuation of a spin superposition through the Stern–Gerlach field. A calculation for single wavepacket development there conforms to observations from the Stern–Gerlach experiment. And several experiments corroborate immediate reduction to a single spin eigenfunction in the magnetic field. Additionally, Ramsey’s separated, oscillating fields observations, and related experiments, do not rebut this understanding.