Review of Scientific Instruments

Optimum design and construction of a Zeeman slower for use with a magneto-optic trap

C. J. Dedman, J. Nes, Thomas M. Hanna, R. G. Dall, K. G. H. Baldwin, Andrew G. Truscott

Published Nov 10, 2004• 46 citations
Publisher

Abstract

A method for optimizing the design and construction of a Zeeman slower coil is presented. Unlike traditional designs, the measured magnetic field profile very accurately matches the desired field profile, enabling significant advantages for loading a magneto-optic trap.
DOI
10.1063/1.1820524

Related papers

A hybrid Zeeman slower for lithium

Davis Garwood, Liyu Liu, Jirayu Mongkolkiattichai +2 more

Zeeman slowers come in two commonly used types: electromagnet-based slowers and permanent-magnet slowers. Both have characteristic advantages and disadvantages. The electric currents required to create strong magnetic fields lead to heat dissipation that limits the achievable fields, while permanent-magnet slowers cause bias magnetic fields at the position of the magneto-optical trap. Here, we combine both approaches and their advantages at our lithium-6 triangular-lattice quantum gas microscope and extend the field of an electromagnet-based Zeeman slower using permanent magnets. We observe nearly doubled loading rates of the magneto-optical trap and no significant stray fields in the trapping region. Our approach allows for a stronger magnetic field in places where geometric constraints prevent the use of coils, and it provides a low-cost upgrade to the loading rate at established experiments.

Review of Scientific Instruments•Mar 1, 2022•7 citations

New approaches in designing a Zeeman Slower

Ben Ohayon, G Ron

We present two new approaches for the design of a Zeeman Slower, which rely on optimal compliance with the adiabatic following condition and are applicable to a wide variety of systems. The first approach is an analytical one, based on the assumption that the noise in the system is position independent. When compared with the traditional approach, which requires constant deceleration, for a typical system, we show an improvement of ∼ 10% in the maximal capture velocity, allowing for a larger slower acceptance, or a reduction of ∼ 25% in slower length, allowing for a simpler design and a better collimated beam. The second approach relies on an optimization of a system in which the magnetic field and the noise profile are well known. As an example, we use our 12-coil modular design and show an improvement of ∼ 9% in maximal capture velocity or, alternatively, a reduction of ∼ 33% in slower length as compared with the traditional approach.

arXiv:1212.2109•Journal of Instrumentation•Feb 22, 2013•15 citations

Zeeman slowing atoms using the magnetic field from a magneto-optical trap

Wen Yan, Yuan Yao, Yuxin Sun +3 more

We study a Zeeman slower using the magnetic field generated by a pair of coils for a magneto-optical trap. The efficiency of the Zeeman slower is shown to be dependent on the intensity and frequency detuning of the laser light for slowing the atoms. With the help of numerical analysis, optimal experimental parameters are explored. Experimentally, the optimal frequency detuning and intensity of the slowing beam are explored, and 4 × 107 ytterbium atoms are trapped in the magneto-optical trap.

Chinese Optics Letters•Jan 1, 2019•1 citation

Investigation of different magnetic field configurations using an electrical, modular Zeeman slower

Ben Ohayon, Guy Ron

We present a method of constructing an automatically reconfigurable, modular, electronic Zeeman slower, which is remotely controlled. This setup is used to investigate the ability of different magnetic field profiles to slow thermal atoms to the capture velocity of a magneto-optical-trap. We show that a simple numerical optimization process yields better results than the commonly used approach for deciding on the appropriate field and comes close to the optimum field, found by utilizing a fast feedback loop which uses a genetic algorithm. Our new numerical method is easily adaptable to a variety of existing slower designs and may be beneficial where feedback is unavailable.

Review of Scientific Instruments•Oct 1, 2015•11 citations

A Double Magneto-optical Trap of 7Li Loaded by a ??--type Zeeman Slower

Huidong Kim, D. Cho

Journal of the Korean Physical Society•May 13, 2011•6 citations

A slow atom source using a collimated effusive oven and a single-layer variable pitch coil Zeeman slower

S. C. Bell, Mark D. Junker, M. Jasperse +4 more

We describe a simple slow atom source for loading a rubidium magneto-optical trap. The source includes an effusive oven with a long heated collimation tube. Almost all components are standard vacuum parts. The heating elements and thermocouples are external to the vacuum, protecting them from the hostile hot alkali environment and allowing repair without breaking vacuum. The thermal source is followed by a Zeeman slower with a single-layer coil of variable winding pitch. The single-layer design is simple to construct and has low inductance which allows for rapid switching of the magnetic field. The coil pitch was determined by fitting the analytic form of the magnetic field for a variable winding pitch to the desired magnetic field profile required to slow atoms. The measured magnetic field for the constructed coil is in excellent agreement with the desired field. The source produces atoms at 35 m/s with a flux up to 2 x 10(10) cm(-2) s(-1) at 200 degrees C.

Review of Scientific Instruments•Jan 1, 2010•42 citations
Zeeman slowers come in two commonly used types: electromagnet-based slowers and permanent-magnet slowers. Both have characteristic advantages and disadvantages. The electric currents required to create strong magnetic fields lead to heat dissipation that limits the achievable fields, while permanent-magnet slowers cause bias magnetic fields at the position of the magneto-optical trap. Here, we combine both approaches and their advantages at our lithium-6 triangular-lattice quantum gas microscope and extend the field of an electromagnet-based Zeeman slower using permanent magnets. We observe nearly doubled loading rates of the magneto-optical trap and no significant stray fields in the trapping region. Our approach allows for a stronger magnetic field in places where geometric constraints prevent the use of coils, and it provides a low-cost upgrade to the loading rate at established experiments.
We present two new approaches for the design of a Zeeman Slower, which rely on optimal compliance with the adiabatic following condition and are applicable to a wide variety of systems. The first approach is an analytical one, based on the assumption that the noise in the system is position independent. When compared with the traditional approach, which requires constant deceleration, for a typical system, we show an improvement of ∼ 10% in the maximal capture velocity, allowing for a larger slower acceptance, or a reduction of ∼ 25% in slower length, allowing for a simpler design and a better collimated beam. The second approach relies on an optimization of a system in which the magnetic field and the noise profile are well known. As an example, we use our 12-coil modular design and show an improvement of ∼ 9% in maximal capture velocity or, alternatively, a reduction of ∼ 33% in slower length as compared with the traditional approach.
We present a method of constructing an automatically reconfigurable, modular, electronic Zeeman slower, which is remotely controlled. This setup is used to investigate the ability of different magnetic field profiles to slow thermal atoms to the capture velocity of a magneto-optical-trap. We show that a simple numerical optimization process yields better results than the commonly used approach for deciding on the appropriate field and comes close to the optimum field, found by utilizing a fast feedback loop which uses a genetic algorithm. Our new numerical method is easily adaptable to a variety of existing slower designs and may be beneficial where feedback is unavailable.
We describe a simple slow atom source for loading a rubidium magneto-optical trap. The source includes an effusive oven with a long heated collimation tube. Almost all components are standard vacuum parts. The heating elements and thermocouples are external to the vacuum, protecting them from the hostile hot alkali environment and allowing repair without breaking vacuum. The thermal source is followed by a Zeeman slower with a single-layer coil of variable winding pitch. The single-layer design is simple to construct and has low inductance which allows for rapid switching of the magnetic field. The coil pitch was determined by fitting the analytic form of the magnetic field for a variable winding pitch to the desired magnetic field profile required to slow atoms. The measured magnetic field for the constructed coil is in excellent agreement with the desired field. The source produces atoms at 35 m/s with a flux up to 2 x 10(10) cm(-2) s(-1) at 200 degrees C.