Journal of Applied Physics

Sensitivity of Josephson junctions in video detection of microwave and millimeter-wave radiation

Hiroshi Ohta

Published Dec 1, 1972• 12 citations
Publisher

Abstract

The responsivity and the noise equivalent power (NEP) of Josephson junctions in video detection of microwave and millimeter-wave radiation have been calculated. The sensitivity to radiation is assumed to be limited by the rounding of the voltage-current curve due to thermal noise of both the source resistance and the junction resistance. The calculated NEP is at least several tens of times better than any experimentally established.

DOI
10.1063/1.1661090

Related papers

Sensitivity of Josephson-effect millimeter-wave radiometer

Hiroshi Ohta, M. J. Feldman, P. T. Parrish +1 more

Résumé. 2014 On calcule la température de bruit et la température minimum détectable d’une jonction Josephson soumise à un rayonnement millimétrique en utilisant l’équation de Fokker-Planck. La température de bruit obtenue peut être très voisine de la température ambiante. Un récepteur pour radiotélescope à très large bande utilisant une jonction Josephson peut avoir une température minimum détectable inférieure à celle d’un maser à ondes progressives. Abstract. 2014 The noise temperature and the minimum detectable temperature of a Josephson junction in video detection of microwave and millimeter-wave radiation has been calculated. We use the well-known method based on a Fokker-Planck equation. The noise temperature can be very close to ambient temperature. Because its predetection bandwidth is very wide, a Josephson-effect radio telescope receiver can have a minimum detectable temperature better than that of a traveling-wave maser. REVUE DE PHYSIQUE APPLIQUÉE TOME 9, JANVIER 1974, PAGE We apply monochromatic radiation to a Josephson junction to determine the frequency dependence of the response. We use a phenomenological model for a Josephson junction, with signal radiation and current noise, described by the equations: These are standard symbols and are given in reference [1]. R is the parallel combination of the junction resistance and the source resistance. The noise current has a white spectum A very important assumption is that the capacitance is small We treat the radiation as a perturbation. The solu-tion of the unperturbed equation without radiation or noise is the voltage-current curve

Revue de Physique Appliquée•Jan 1, 1974•8 citations

Millimeter-wave detection by YBaCuO step-edge microbridge Josephson junction

Yoshito Fukumoto, Rikuo Ogawa, Yoshio Kawate

Millimeter-wave detection was investigated using a step-edge microbridge Josephson junction fabricated by a YBaCuO thin film for both the video detection and harmonic mixing detection. Current–voltage (I–V) characteristics, which could be described by the resistively shunted junction (RSJ) model, were obtained up to 70 K with the IcR product of 150 μV at 70 K. The responsivity and noise equivalent input power were calculated as 2400 W/V and 4.4×10−14 W/√Hz, respectively, in the video detection assuming the RSJ model approximation. Clear dependence of the intermediate frequency output on the applied dc bias voltage was observed in the harmonic mixing detection with the harmonic numbers of 5–16, reflecting the change of dynamic resistance at the constant voltage steps induced by the local oscillation signal on the I–V curve. A minimum detection power of −59.4 dB m and a conversion efficiency (η) of −49.6 dB were obtained for the harmonic number (N) of 5 at 60 K. The relationship between the η and N was expressed as η∝N−2.2.

Journal of Applied Physics•Sep 1, 1993•14 citations

Resonant switching current detector based on underdamped Josephson junctions

V. M. Krasnov

Current-biased Josephson junctions can act as detectors of electromagnetic radiation. At optimal conditions, their sensitivity is limited by fluctuations causing stochastic switching from the superconducting to the resistive state. This work provides a quantitative description of a stochastic switching current detector, based on an underdamped Josephson junction. It is shown that activation of a Josephson plasma resonance can greatly enhance the detector responsivity in proportion to the quality factor of the junction. The ways of tuning the detector for achieving optimal operation are discussed. For realistic parameters of Nb / Al O x / Nb tunnel junctions, the sensitivity and noise-equivalent power (NEP) can reach values of S ≃ 5 × 10 12 (V/W) and NEP ≃ 2 × 10 − 23 ( WHz − 1 / 2 ), respectively. These outstanding characteristics facilitate both bolometric and single-photon detection in microwave and terahertz ranges. Published by the American Physical Society 2024

arXiv:2403.03803•Physical Review Applied•Aug 6, 2024•10 citations

Wideband detection of electromagnetic signals by high-Tc Josephson junctions with comparable Josephson and thermal energies

Valery V. Pavlovskiy, I. Gundareva, O. Yu. Volkov +1 more

Detection mechanisms in Josephson junctions with energies Ej comparable to thermal energies kT have been studied. The responses ΔV of YBa2Cu3O7−x bicrystal junctions to monochromatic radiation with frequencies f ranging from 94 GHz to 3.1 THz can be described in terms of classical rectification on a static nonlinear V–I curve at low frequencies and frequency modulation of the ac Josephson current at high frequencies, with an interplay between these mechanisms at intermediate frequencies. An electrical noise-equivalent power of (9 ± 3) × 10−15 W/Hz1/2, a responsivity of (3.4 ± 0.5) × 105 V/W, and a dynamic power range of 5 × 104 have been demonstrated for the square-law classical detection of 94 GHz radiation with the junctions at 50 K. The effect of background radiation on the V–I curves of YBa2Cu3O7−x bicrystal junctions was found to have an optical noise-equivalent temperature of ≤30 mK/Hz1/2. The main contribution to the effect comes from the interplay between the classical and Josephson detection mechanisms. The spectral and power dependencies of the responses ΔV of Josephson junctions have been numerically simulated within the resistively shunted junction model at various values of kT/Ej, and the results are in acceptable agreement with the experimental data.

Applied Physics Letters•Feb 24, 2020•10 citations

Broadband THz detection by high-Tc Josephson junctions

Yu. Ya. Divin, Valery V. Pavlovskiy, D.A. Tkachev +3 more

Detection of THz radiation by YBa2Cu3O7-xJosephson bicrystal junctions with high characteristic voltages IcRnup to 8 mV has been studied. The high-resistance junctions have demonstrated a classical detection of radiation with frequencies up to terahertz range. It was shown by numerical simulations, that the values of noise equivalent power NEP-15W/Hz1/2can be reached at the frequencies up to 1.5 THz at junction temperature of 30 K.

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)•Sep 1, 2006•1 citation

ミリ波・サブミリ波検出器

Kazuo Fujisawa

In this report, Josephson junction detectors for millimeter and submillimeter waves are surveyed. Emphasis is placed on heterodyne detectors (mixers). Others are briefly referred to, such as video detectors, bolometers, quasiparticle mixers and parametric amplifiers. Also, three kinds of Josephson junctions for detector use are mentioned and brief comments are given on them. These are tunnel junctions, thin film microbridges and point contacts.Thermally cyclable oxide barrier tunnel junctions have been obtained and used as low noise quasiparticle mixers at 115GHz. They have lower noise temperatures compared to Josephson effect mixers, but the receiver noise temperatures are not lowered owing to their lower conversion efficiencies. Thin film microbridges suffer from low junction resistances and also from heating effects caused by d.c. bias supply and r.f. incident power. There seems to exist many problems to be overcome in order to make good submillimeter wave detectors by tunnel junctions or microbridges.Point contacts are now widely used as sensitive detectors for millimeter and submillimeter waves. Although there exist difficulties for making rugged and thermally cyclable point contacts, the techniques for making them have made considerable progress, and a new construction of detector mount has appeared, which brought a low noise mixer at 115GHz thermally cyclable.It is shown that the sensitivity of video detectors decreases as proportional to the inverse square of frequency. So, for submillimeter waves, video detectors are inferior to superconducting bolometers.Recent progress in heterodyne detectors (fundamental and harmonic mixers) are touched on. They are superior to Shottky diode mixers in that they have much smaller NEP's and much higher conversion efficiencies (especially in harmonic mixers), and also in that they operate with much smaller LO power. Experimental curves of IF output power v.s. bias voltage are given for harmonic mixers with harmonic number N=7 and N=10. It is noted that harmonic mixers with even harmonic number are preferable, because they can operate at zero bias voltage. Among them, low even numbers 2 or 4 are recommended in regards to good conversion efficiency.By using Josephson junctions, a peculiar parametric operation is possible, namely doubly degenerate mode. This mode operates under zero d.c. bias by choosing pump frequency as 2ωp=ωs+ωi, ωp-ωs-ωi. Zero bias operation allows the adoption of microbridge arrays. A parametric amplifier with 160 microbridge arrays was built at 33GHz, and showed amplifier gain of 15dB and noise temperature of 20K.

TEION KOGAKU (Journal of Cryogenics and Superconductivity Society of Japan)•Jan 1, 1980•0 citations
The responsivity and the noise equivalent power (NEP) of Josephson junctions in video detection of microwave and millimeter-wave radiation have been calculated. The sensitivity to radiation is assumed to be limited by the rounding of the voltage-current curve due to thermal noise of both the source resistance and the junction resistance. The calculated NEP is at least several tens of times better than any experimentally established.
Résumé. 2014 On calcule la température de bruit et la température minimum détectable d’une jonction Josephson soumise à un rayonnement millimétrique en utilisant l’équation de Fokker-Planck. La température de bruit obtenue peut être très voisine de la température ambiante. Un récepteur pour radiotélescope à très large bande utilisant une jonction Josephson peut avoir une température minimum détectable inférieure à celle d’un maser à ondes progressives. Abstract. 2014 The noise temperature and the minimum detectable temperature of a Josephson junction in video detection of microwave and millimeter-wave radiation has been calculated. We use the well-known method based on a Fokker-Planck equation. The noise temperature can be very close to ambient temperature. Because its predetection bandwidth is very wide, a Josephson-effect radio telescope receiver can have a minimum detectable temperature better than that of a traveling-wave maser. REVUE DE PHYSIQUE APPLIQUÉE TOME 9, JANVIER 1974, PAGE We apply monochromatic radiation to a Josephson junction to determine the frequency dependence of the response. We use a phenomenological model for a Josephson junction, with signal radiation and current noise, described by the equations: These are standard symbols and are given in reference [1]. R is the parallel combination of the junction resistance and the source resistance. The noise current has a white spectum A very important assumption is that the capacitance is small We treat the radiation as a perturbation. The solu-tion of the unperturbed equation without radiation or noise is the voltage-current curve
Millimeter-wave detection was investigated using a step-edge microbridge Josephson junction fabricated by a YBaCuO thin film for both the video detection and harmonic mixing detection. Current–voltage (I–V) characteristics, which could be described by the resistively shunted junction (RSJ) model, were obtained up to 70 K with the IcR product of 150 μV at 70 K. The responsivity and noise equivalent input power were calculated as 2400 W/V and 4.4×10−14 W/√Hz, respectively, in the video detection assuming the RSJ model approximation. Clear dependence of the intermediate frequency output on the applied dc bias voltage was observed in the harmonic mixing detection with the harmonic numbers of 5–16, reflecting the change of dynamic resistance at the constant voltage steps induced by the local oscillation signal on the I–V curve. A minimum detection power of −59.4 dB m and a conversion efficiency (η) of −49.6 dB were obtained for the harmonic number (N) of 5 at 60 K. The relationship between the η and N was expressed as η∝N−2.2.
Current-biased Josephson junctions can act as detectors of electromagnetic radiation. At optimal conditions, their sensitivity is limited by fluctuations causing stochastic switching from the superconducting to the resistive state. This work provides a quantitative description of a stochastic switching current detector, based on an underdamped Josephson junction. It is shown that activation of a Josephson plasma resonance can greatly enhance the detector responsivity in proportion to the quality factor of the junction. The ways of tuning the detector for achieving optimal operation are discussed. For realistic parameters of Nb / Al O x / Nb tunnel junctions, the sensitivity and noise-equivalent power (NEP) can reach values of S ≃ 5 × 10 12 (V/W) and NEP ≃ 2 × 10 − 23 ( WHz − 1 / 2 ), respectively. These outstanding characteristics facilitate both bolometric and single-photon detection in microwave and terahertz ranges. Published by the American Physical Society 2024
Detection mechanisms in Josephson junctions with energies Ej comparable to thermal energies kT have been studied. The responses ΔV of YBa2Cu3O7−x bicrystal junctions to monochromatic radiation with frequencies f ranging from 94 GHz to 3.1 THz can be described in terms of classical rectification on a static nonlinear V–I curve at low frequencies and frequency modulation of the ac Josephson current at high frequencies, with an interplay between these mechanisms at intermediate frequencies. An electrical noise-equivalent power of (9 ± 3) × 10−15 W/Hz1/2, a responsivity of (3.4 ± 0.5) × 105 V/W, and a dynamic power range of 5 × 104 have been demonstrated for the square-law classical detection of 94 GHz radiation with the junctions at 50 K. The effect of background radiation on the V–I curves of YBa2Cu3O7−x bicrystal junctions was found to have an optical noise-equivalent temperature of ≤30 mK/Hz1/2. The main contribution to the effect comes from the interplay between the classical and Josephson detection mechanisms. The spectral and power dependencies of the responses ΔV of Josephson junctions have been numerically simulated within the resistively shunted junction model at various values of kT/Ej, and the results are in acceptable agreement with the experimental data.
In this report, Josephson junction detectors for millimeter and submillimeter waves are surveyed. Emphasis is placed on heterodyne detectors (mixers). Others are briefly referred to, such as video detectors, bolometers, quasiparticle mixers and parametric amplifiers. Also, three kinds of Josephson junctions for detector use are mentioned and brief comments are given on them. These are tunnel junctions, thin film microbridges and point contacts.Thermally cyclable oxide barrier tunnel junctions have been obtained and used as low noise quasiparticle mixers at 115GHz. They have lower noise temperatures compared to Josephson effect mixers, but the receiver noise temperatures are not lowered owing to their lower conversion efficiencies. Thin film microbridges suffer from low junction resistances and also from heating effects caused by d.c. bias supply and r.f. incident power. There seems to exist many problems to be overcome in order to make good submillimeter wave detectors by tunnel junctions or microbridges.Point contacts are now widely used as sensitive detectors for millimeter and submillimeter waves. Although there exist difficulties for making rugged and thermally cyclable point contacts, the techniques for making them have made considerable progress, and a new construction of detector mount has appeared, which brought a low noise mixer at 115GHz thermally cyclable.It is shown that the sensitivity of video detectors decreases as proportional to the inverse square of frequency. So, for submillimeter waves, video detectors are inferior to superconducting bolometers.Recent progress in heterodyne detectors (fundamental and harmonic mixers) are touched on. They are superior to Shottky diode mixers in that they have much smaller NEP's and much higher conversion efficiencies (especially in harmonic mixers), and also in that they operate with much smaller LO power. Experimental curves of IF output power v.s. bias voltage are given for harmonic mixers with harmonic number N=7 and N=10. It is noted that harmonic mixers with even harmonic number are preferable, because they can operate at zero bias voltage. Among them, low even numbers 2 or 4 are recommended in regards to good conversion efficiency.By using Josephson junctions, a peculiar parametric operation is possible, namely doubly degenerate mode. This mode operates under zero d.c. bias by choosing pump frequency as 2ωp=ωs+ωi, ωp-ωs-ωi. Zero bias operation allows the adoption of microbridge arrays. A parametric amplifier with 160 microbridge arrays was built at 33GHz, and showed amplifier gain of 15dB and noise temperature of 20K.