Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Letters

Polarization-based balanced heterodyne detection method in a Sagnac interferometer for precision phase measurement

Ke-Xun Sun, Eric K. Gustafson, M. M. Fejer, Robert L. Byer

Published Sep 1, 1997• 30 citations
Publisher

Abstract

We describe a balanced heterodyne detection method for a Sagnac interferometer that uses a polarization-dependent beam splitter. The signal and the local oscillator are orthogonally polarized components of a single laser beam, permitting the detection of the signal by subtraction of two photocurrents produced in appropriate polarization projections. Using this scheme, we experimentally demonstrate a phase measurement with a sensitivity of 9x10(-10) rad/ radicalHz. The measurement is robust in the presence of laser frequency noise, as a result of preserving the common-path nature of the Sagnac interferometer, and of laser-amplitude noise, as a result of balanced detection.

DOI
10.1364/ol.22.001359

Related papers

Differential phase decoder in a polarized optical heterodyne interferometer

Chien Chou, Hui-Kang Teng, Chien-Chung Tsai +1 more

A differential-phase decoder (DPD) together with a polarization common-path optical heterodyne interferometer is set up. Based on this interferometric configuration and a novel balanced-detector scheme, the performance of the quantum-noise-limited differential-phase decoder is demonstrated and analyzed. The minimum-detectable differential phase is on the order of 10(-7) rad/sqrt Hz when a 2.5 mW He-Ne laser is used. Verified experimentally, the DPD is immune to the common-phase noise induced by an electro-optic phase modulator or by thermal disturbance within the interferometer. This signifies that the minimum-detectable differential phase can become 10(-8) rad/sqrt Hz if a 300 mW continuous wave laser is employed instead.

Journal of the Optical Society of America A•Oct 2, 2008•6 citations

Modulation-Free Frequency Stabilization Based on Polarization-Split Sagnac Loop

Fang Wei, Dijun Chen, Yanguang Sun +3 more

A novel frequency stabilization method for external cavity diode lasers by using an all-pass polarization-split Sagnac loop is proposed. This scheme uses a quarter waveplate to convert the incident beam to a circularly polarized beam, and a polarization beam splitter for the input and output of the Sagnac loop. The two beams with perpendicular polarizations counter-propagate in the loop and experience different absorption of the Rb cell; therefore, the Sagnac loop output beam is converted into elliptical polarization. The dispersion phase shift induced by Rb saturation absorption can be obtained by balanced polarization-divided detection of the Sagnac loop output beam. The experimental results showed the feasibility and merits of the new method. This scheme is simple, robust, low-cost, and has potential applications in atomic physics experiments.

IEEE Photonics Technology Letters•May 1, 2013•8 citations

Mapping of local complex reflection coefficient variations using a scanning multi-port homodyne interferometer

H. Jeong, K. Cho

Summary form only given. We present a novel multi-port balanced homodyne interferometer scheme, that can simultaneously determine the quadrature phases of the signal beam. This interferometer consists of two identical balanced homodyne interferometers, in which the local oscillators of the corresponding interferometers, have /spl pi//2 phase difference with respect to each other. In this scheme, two identical interferometers for quadrature measurements are constructed by the use of the corresponding polarization components of the signal and local oscillator beams, i.e., principal polarizations of the signal and local oscillator beams are used as independent interferometers. A /spl pi//4 phase shift between the reflected and transmitted polarization components at a polarizing beamsplitter, which was observed in our experiment, was used to provide two local oscillators with /spl pi//2 phase difference. Output interference signals from the corresponding. balanced interferometers, I and Q, respectively, can be written as, I=/spl eta/|E/sub LO/|E/sub s/| cos(/spl Delta//spl phi/),Q=/spl eta/|E/sub LO/|E/sub s/|sin(/spl Delta//spl phi/), where /spl eta/ is the quantum efficiency of photodiode, |E/sub s/| and |E/sub LO/| are the amplitude of signal and local oscillator beam, respectively, and /spl Delta//spl phi/ is the phase difference between signal and local oscillator.

Conference on Lasers and Electro-Optics•Jan 1, 2001•0 citations

Continuous phase amplification with a Sagnac interferometer

David J. Starling, P. Ben Dixon, Nathan S. Williams +2 more

We describe a phase-amplification technique using a Sagnac interferometer. We monitor the relative phase between two paths of a precisely misaligned interferometer by measuring the average position of a split-Gaussian mode in the dark port. Although we monitor only the dark port, we show that the signal varies linearly with phase and that we can obtain similar sensitivity to balanced homodyne detection. We derive the source of the amplification using classical wave optics.

arXiv:0912.2357•Physical Review A•Jul 8, 2010•139 citations

Single-frequency laser phase-noise limitation in single-mode optical-fiber coherent-detection systems with correlated fields

Philippe B. Gallion, Francisco Javier Mendieta, R. Leconte

The phase noise affecting the beat photocurrent produced by coherent detection of a single-frequency laser field with a time-delayed and frequency-shifted image of itself in a heterodyne two-wave interferometric system using a single-mode optical fiber is investigated as a function of source spectrum and phase-decorrelation time under the assumptions of quantum laser phase noise and high-local-oscillation level. The influence on the photocurrent spectrum of partial correlation between detected fields is pointed out. These calculations are an extension of a previously reported high-resolution spectroscopic method and account for the phase-noise limitation in unbalanced heterodyne fiber sensors and heterodyne-transmission receivers with an optical reference wave generated from the received signal. An experimental study is reported consisting of a Mach–Zender-type interferometer employing a single-frequency amplitude-stabilized laser, an acousto-optical single-side-band modulator for frequency shifting one of the arms, and several lengths of single-mode optical fiber to decorrelate the detected fields partially. Results are found to be in good agreement with theory.

Journal of the Optical Society of America•Sep 1, 1982•42 citations

Supersensitive phase estimation for hybrid interferometer using balanced homodyne detection

Tao Shao, Minyang Zhang, Chenlu Li +4 more

Abstract We have theoretically investigated the phase sensitivity of the hybrid interferometer with two coherent beams using the method of balance homodyne detection. The measurement device is a nonlinear–linear hybrid interferometer consisting of an optical parametric amplifier and a beam splitter. We prove that the phase sensitivity can beat the shot noise limit in the optimal conditions. Furthermore, we derive the quantum Cramér–Rao bound of the hybrid interferometer. The effects of transmission loss and detection loss on the measurement accuracy are discussed. The detection accuracy of this scheme is compared with that of the conventional SU (1,1) interferometer. Our results show that this scheme outperforms the conventional SU (1,1) interferometer scheme at high parametric strength. This scheme can be implemented with existing experimental techniques and will have important applications in quantum precision measurements.

Journal of Physics B Atomic Molecular and Optical Physics•Oct 24, 2023•4 citations
We describe a balanced heterodyne detection method for a Sagnac interferometer that uses a polarization-dependent beam splitter. The signal and the local oscillator are orthogonally polarized components of a single laser beam, permitting the detection of the signal by subtraction of two photocurrents produced in appropriate polarization projections. Using this scheme, we experimentally demonstrate a phase measurement with a sensitivity of 9x10(-10) rad/ radicalHz. The measurement is robust in the presence of laser frequency noise, as a result of preserving the common-path nature of the Sagnac interferometer, and of laser-amplitude noise, as a result of balanced detection.
A differential-phase decoder (DPD) together with a polarization common-path optical heterodyne interferometer is set up. Based on this interferometric configuration and a novel balanced-detector scheme, the performance of the quantum-noise-limited differential-phase decoder is demonstrated and analyzed. The minimum-detectable differential phase is on the order of 10(-7) rad/sqrt Hz when a 2.5 mW He-Ne laser is used. Verified experimentally, the DPD is immune to the common-phase noise induced by an electro-optic phase modulator or by thermal disturbance within the interferometer. This signifies that the minimum-detectable differential phase can become 10(-8) rad/sqrt Hz if a 300 mW continuous wave laser is employed instead.
A novel frequency stabilization method for external cavity diode lasers by using an all-pass polarization-split Sagnac loop is proposed. This scheme uses a quarter waveplate to convert the incident beam to a circularly polarized beam, and a polarization beam splitter for the input and output of the Sagnac loop. The two beams with perpendicular polarizations counter-propagate in the loop and experience different absorption of the Rb cell; therefore, the Sagnac loop output beam is converted into elliptical polarization. The dispersion phase shift induced by Rb saturation absorption can be obtained by balanced polarization-divided detection of the Sagnac loop output beam. The experimental results showed the feasibility and merits of the new method. This scheme is simple, robust, low-cost, and has potential applications in atomic physics experiments.
Summary form only given. We present a novel multi-port balanced homodyne interferometer scheme, that can simultaneously determine the quadrature phases of the signal beam. This interferometer consists of two identical balanced homodyne interferometers, in which the local oscillators of the corresponding interferometers, have /spl pi//2 phase difference with respect to each other. In this scheme, two identical interferometers for quadrature measurements are constructed by the use of the corresponding polarization components of the signal and local oscillator beams, i.e., principal polarizations of the signal and local oscillator beams are used as independent interferometers. A /spl pi//4 phase shift between the reflected and transmitted polarization components at a polarizing beamsplitter, which was observed in our experiment, was used to provide two local oscillators with /spl pi//2 phase difference. Output interference signals from the corresponding. balanced interferometers, I and Q, respectively, can be written as, I=/spl eta/|E/sub LO/|E/sub s/| cos(/spl Delta//spl phi/),Q=/spl eta/|E/sub LO/|E/sub s/|sin(/spl Delta//spl phi/), where /spl eta/ is the quantum efficiency of photodiode, |E/sub s/| and |E/sub LO/| are the amplitude of signal and local oscillator beam, respectively, and /spl Delta//spl phi/ is the phase difference between signal and local oscillator.
The phase noise affecting the beat photocurrent produced by coherent detection of a single-frequency laser field with a time-delayed and frequency-shifted image of itself in a heterodyne two-wave interferometric system using a single-mode optical fiber is investigated as a function of source spectrum and phase-decorrelation time under the assumptions of quantum laser phase noise and high-local-oscillation level. The influence on the photocurrent spectrum of partial correlation between detected fields is pointed out. These calculations are an extension of a previously reported high-resolution spectroscopic method and account for the phase-noise limitation in unbalanced heterodyne fiber sensors and heterodyne-transmission receivers with an optical reference wave generated from the received signal. An experimental study is reported consisting of a Mach–Zender-type interferometer employing a single-frequency amplitude-stabilized laser, an acousto-optical single-side-band modulator for frequency shifting one of the arms, and several lengths of single-mode optical fiber to decorrelate the detected fields partially. Results are found to be in good agreement with theory.
Abstract We have theoretically investigated the phase sensitivity of the hybrid interferometer with two coherent beams using the method of balance homodyne detection. The measurement device is a nonlinear–linear hybrid interferometer consisting of an optical parametric amplifier and a beam splitter. We prove that the phase sensitivity can beat the shot noise limit in the optimal conditions. Furthermore, we derive the quantum Cramér–Rao bound of the hybrid interferometer. The effects of transmission loss and detection loss on the measurement accuracy are discussed. The detection accuracy of this scheme is compared with that of the conventional SU (1,1) interferometer. Our results show that this scheme outperforms the conventional SU (1,1) interferometer scheme at high parametric strength. This scheme can be implemented with existing experimental techniques and will have important applications in quantum precision measurements.