Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Science

Tinker-Free Interferometry

Published Dec 13, 2007• 0 citations
Publisher

Abstract

The interference of waves, be they photons, atoms, or electrons, and the measured phase shift induced as the waves take a different route around the arms of an interferometer are widely used in applications ranging from global positioning systems and gravity wave detectors down to the more mundane characterization of optical materials. The sensitivity of the interferometer in measuring the phase shift is affected by noise contributions to the signal. To combat this noise, piezoelectric actuators are typically used to adjust the system to an optimum measuring point for maximum sensitivity. This approach has drawbacks, however, for certain applications where the determination of arbitrary phase shifts is important. Pezzé et al. introduce a method and protocol of photon counting at the output paths to determine the phase. They show that the classical, or thermal, noise can be eliminated without bias (i.e., no tinkering with the phase shift is necessary). At this quantum limit, only quantum uncertainty affects the precision of the phase measurement. — ISO

DOI
10.1126/science.318.5857.1699b

Related papers

Quantum Interferometry with Gaussian States

Ulrik L. Andersen, O. Glöckl, Tobias Gehring +1 more

The concept of quantum interference is at the very heart of quantum physics and appears in many areas. Most of the applications of interferometric light interference are concerned with the estimation of a linear phase shift between the two arms of a Mach-Zehnder interferometer, and to quantify the performance of the interferometer. One needs to address the precision by which this phase difference can be estimated. This chapter focuses on one simple setup with different combinations of Gaussian states at the input and using simple calculus to determine the interferometric precision. In real-life experiments, the concept of photon loss is important. The chapter deals with a short discussion of photon loss. For the Gaussian schemes mentioned, sub-shot-noise sensitivity is obtained for any nonvanishing squeezing even in the presence of photon loss. Finally, the chapter discusses quantum interferometry using non-Gaussian states.

Wiley eBooks•Apr 18, 2016•6 citations

Interferometry using injection-locked pump-noise-suppressed semiconductor lasers

Gunnar G. Bjork, Shuichiro Inoue, Y. Yamamoto

In a conventional interferometer one shines light only into one interferometer input port while the second input port is unexcited. This allows vacuum states to enter the unexcited port, leading to imperfect correlation between both the amplitude and the phase fluctuations of the light in the upper and lower interferometer arms. This, in turn, limits the interferometer sensitivity regardless of its operating panel (its arm-length difference, which we in the following will translate into a phase shift θ). The sensitivity of an ideal conventional interferometer is 1 / N. That is, a phase shift of 1 / N radians can be detected with a signal-to-noise ratio of unity by using N photons. Since N typically is a large number, it is tempting to try to find some scheme approaching the fundamental (Heisenberg) limit of phase-shift detection, 1/N. One way of doing that is to inject squeezed vacuum into the unexcited input port of the interferometer.1

•May 8, 1994•0 citations

Adaptive measurements and optimal states for quantum interferometry

Dominic William Berry, Howard M. Wiseman

Summary form only given. Interferometry is the basis of many high-precision measurements. The ultimate limit to the precision is due to quantum effects. This limit is most easily explored for a Mach-Zehnder interferometer The outputs of this device can be measured to yield an estimate /spl phi/ of the phase difference /spl phi/ between the two arms of the interferometer. It is well known that this can achieve the standard quantum limit for phase variance when an N-photon number state enters one input port. Several authors have proposed ways of reducing the phase variance to the Heisenberg limit. In this paper we show that there is a physical measurement scheme using photodetectors and feedback that is almost as good as the optimal measurement. The fundamental idea is that, in addition to the unknown phase we wish to measure, /spl phi/, in one arm of the interferometer, we introduce a known phase shift, /spl Phi/, into the other arm of the interferometer. After each photodetection we adjust this introduced phase shift in order to minimize the expected uncertainty of our best phase estimate /spl phi/ after the next photodetection. This feedback process is uniquely defined using Bayesian statistics, and can be solved exactly for moderate photon numbers.

Quantum Electronics and Laser Science Conference•Nov 13, 2002•2 citations

Noise limits on two-photon interferometric sensing

Hamish Scott, Dominic Branford, Niclas Westerberg +2 more

When a photon interferes with itself while traversing a Mach-Zehnder interferometer, the output port where it emerges is influenced by the phase difference between the interferometer arms. This allows for highly precise estimation of the path length difference (delay) but is extremely sensitive to phase noise. By contrast, a delay between the arms of the two-photon Hong-Ou-Mandel interferometer directly affects the relative indistinguishability of the photon pair, affecting the rate of recorded coincidences. This likewise allows for delay estimation, notably less precise but with the advantage of being less sensitive to perturbations of the photons' phase. Focusing on two-photon input states, we here investigate to what degree of noise Mach-Zehnder interferometry retains its edge over Hong-Ou-Mandel interferometry. We also explore the competing benefits of different two-photon inputs for a Mach-Zehnder interferometer and under what parameter regimes each input performs best.

arXiv:2106.13671•Physical Review A•Nov 9, 2021•17 citations

Diffraction-phase-free Bragg atom interferometry

V. J. Martínez-Lahuerta, Jan-Niclas Kirsten-Siemß, Klemens Hammerer +1 more

Bragg diffraction of matter waves is an established technique used in the most accurate quantum sensors. It is also the method of choice to operate large-momentum-transfer, high-sensitivity atom interferometers. It suffers, however, from an intrinsic multi-path character. Optimal control theory (OCT) has recently led to an improved robustness of atom interferometers to a range of challenging environmental effects such as vibrations or platform accelerations. In this theoretical work, we apply OCT protocols to control the Bragg diffraction phase shifts, thereby enhancing the metrological accuracy of the interferometer. We show a minimization of the diffraction phase for realistic conditions of finite temperature of the incoming wavepacket in a multi-path, high-order Bragg interferometer in a Mach–Zehnder configuration. We study input states with different momentum widths and find that our approach mitigates diffraction phases below the microradian level in the case of 1% of the photon recoil, thereby eliminating one of the leading systematic effects in atom interferometry.

arXiv:2505.23921•AVS Quantum Science•Mar 1, 2026•4 citations

A Matter of Extended Coherence

The splitting and subsequent re-overlapping of a coherent light beam provides the basis for exquisitely sensitive detection of path-length differences; this technique of optical interferometry finds applications ranging from stellar observations to holographic imaging and characterization of optical components. Analogously, the cooling of a cloud of bosonic atoms into a Bose-Einstein condensate, a state in which all the atoms share the same quantum state, is described in terms of a coherent matter wave. Because atoms sense gravity, the interference of matter waves can then be used to provide a sensitive gravity detector, with a comparably diverse set of applications ranging from testing relativity to detecting underground bunkers. Unlike photons, however, which do not interact much with each other, the atoms in the trapped cloud do interact by way of collisions. These collisions then give rise to losses and induce shifts in the phase of the matter wave, thereby limiting the sensitivity of any atom interferometer. Gustavsson et al. and Fattori et al. present setups in which the interaction strength between the atoms in the condensate (cesium and potassium, respectively) is tuned via magnetic field so that the scattering between the atoms is significantly reduced. The resulting extension of the matter-wave coherence time leads to improved sensitivity of the atom interferometers. — ISO

Science•Mar 20, 2008•0 citations
The interference of waves, be they photons, atoms, or electrons, and the measured phase shift induced as the waves take a different route around the arms of an interferometer are widely used in applications ranging from global positioning systems and gravity wave detectors down to the more mundane characterization of optical materials. The sensitivity of the interferometer in measuring the phase shift is affected by noise contributions to the signal. To combat this noise, piezoelectric actuators are typically used to adjust the system to an optimum measuring point for maximum sensitivity. This approach has drawbacks, however, for certain applications where the determination of arbitrary phase shifts is important. Pezzé et al. introduce a method and protocol of photon counting at the output paths to determine the phase. They show that the classical, or thermal, noise can be eliminated without bias (i.e., no tinkering with the phase shift is necessary). At this quantum limit, only quantum uncertainty affects the precision of the phase measurement. — ISO
The concept of quantum interference is at the very heart of quantum physics and appears in many areas. Most of the applications of interferometric light interference are concerned with the estimation of a linear phase shift between the two arms of a Mach-Zehnder interferometer, and to quantify the performance of the interferometer. One needs to address the precision by which this phase difference can be estimated. This chapter focuses on one simple setup with different combinations of Gaussian states at the input and using simple calculus to determine the interferometric precision. In real-life experiments, the concept of photon loss is important. The chapter deals with a short discussion of photon loss. For the Gaussian schemes mentioned, sub-shot-noise sensitivity is obtained for any nonvanishing squeezing even in the presence of photon loss. Finally, the chapter discusses quantum interferometry using non-Gaussian states.
In a conventional interferometer one shines light only into one interferometer input port while the second input port is unexcited. This allows vacuum states to enter the unexcited port, leading to imperfect correlation between both the amplitude and the phase fluctuations of the light in the upper and lower interferometer arms. This, in turn, limits the interferometer sensitivity regardless of its operating panel (its arm-length difference, which we in the following will translate into a phase shift θ). The sensitivity of an ideal conventional interferometer is 1 / N. That is, a phase shift of 1 / N radians can be detected with a signal-to-noise ratio of unity by using N photons. Since N typically is a large number, it is tempting to try to find some scheme approaching the fundamental (Heisenberg) limit of phase-shift detection, 1/N. One way of doing that is to inject squeezed vacuum into the unexcited input port of the interferometer.1
Summary form only given. Interferometry is the basis of many high-precision measurements. The ultimate limit to the precision is due to quantum effects. This limit is most easily explored for a Mach-Zehnder interferometer The outputs of this device can be measured to yield an estimate /spl phi/ of the phase difference /spl phi/ between the two arms of the interferometer. It is well known that this can achieve the standard quantum limit for phase variance when an N-photon number state enters one input port. Several authors have proposed ways of reducing the phase variance to the Heisenberg limit. In this paper we show that there is a physical measurement scheme using photodetectors and feedback that is almost as good as the optimal measurement. The fundamental idea is that, in addition to the unknown phase we wish to measure, /spl phi/, in one arm of the interferometer, we introduce a known phase shift, /spl Phi/, into the other arm of the interferometer. After each photodetection we adjust this introduced phase shift in order to minimize the expected uncertainty of our best phase estimate /spl phi/ after the next photodetection. This feedback process is uniquely defined using Bayesian statistics, and can be solved exactly for moderate photon numbers.
When a photon interferes with itself while traversing a Mach-Zehnder interferometer, the output port where it emerges is influenced by the phase difference between the interferometer arms. This allows for highly precise estimation of the path length difference (delay) but is extremely sensitive to phase noise. By contrast, a delay between the arms of the two-photon Hong-Ou-Mandel interferometer directly affects the relative indistinguishability of the photon pair, affecting the rate of recorded coincidences. This likewise allows for delay estimation, notably less precise but with the advantage of being less sensitive to perturbations of the photons' phase. Focusing on two-photon input states, we here investigate to what degree of noise Mach-Zehnder interferometry retains its edge over Hong-Ou-Mandel interferometry. We also explore the competing benefits of different two-photon inputs for a Mach-Zehnder interferometer and under what parameter regimes each input performs best.
Bragg diffraction of matter waves is an established technique used in the most accurate quantum sensors. It is also the method of choice to operate large-momentum-transfer, high-sensitivity atom interferometers. It suffers, however, from an intrinsic multi-path character. Optimal control theory (OCT) has recently led to an improved robustness of atom interferometers to a range of challenging environmental effects such as vibrations or platform accelerations. In this theoretical work, we apply OCT protocols to control the Bragg diffraction phase shifts, thereby enhancing the metrological accuracy of the interferometer. We show a minimization of the diffraction phase for realistic conditions of finite temperature of the incoming wavepacket in a multi-path, high-order Bragg interferometer in a Mach–Zehnder configuration. We study input states with different momentum widths and find that our approach mitigates diffraction phases below the microradian level in the case of 1% of the photon recoil, thereby eliminating one of the leading systematic effects in atom interferometry.
The splitting and subsequent re-overlapping of a coherent light beam provides the basis for exquisitely sensitive detection of path-length differences; this technique of optical interferometry finds applications ranging from stellar observations to holographic imaging and characterization of optical components. Analogously, the cooling of a cloud of bosonic atoms into a Bose-Einstein condensate, a state in which all the atoms share the same quantum state, is described in terms of a coherent matter wave. Because atoms sense gravity, the interference of matter waves can then be used to provide a sensitive gravity detector, with a comparably diverse set of applications ranging from testing relativity to detecting underground bunkers. Unlike photons, however, which do not interact much with each other, the atoms in the trapped cloud do interact by way of collisions. These collisions then give rise to losses and induce shifts in the phase of the matter wave, thereby limiting the sensitivity of any atom interferometer. Gustavsson et al. and Fattori et al. present setups in which the interaction strength between the atoms in the condensate (cesium and potassium, respectively) is tuned via magnetic field so that the scattering between the atoms is significantly reduced. The resulting extension of the matter-wave coherence time leads to improved sensitivity of the atom interferometers. — ISO