European Quantum Electronics Conference (EQEC)

A cold atom interferometer for high precision measurements

F. Yver, Arnaud Landragin, N. Dimarcq, Andr  Clairon, David Holleville, Patrick Cheinet, Philippe Bouyer, Ch Salomon, Ch. J. Bordé

Published Jan 1, 2003• 0 citations
Publisher

Abstract

We build a cold atom interferometer to be used as high precision inertial sensor. Our setup is sensitive both to rotations and accelerations. The interferometer configuration is similar to an optical Mach-Zehnder interferometer, and it uses stimulated Raman transitions to manipulate the atomic wave packets (total interferometer time of 90 ms).

DOI
10.1109/eqec.2003.1314166

Related papers

A cold atom interferometer for high precision inertial measurements

B. Canuel, Florence Leduc, David Holleville +6 more

The authors are developing a high precision inertial sensor. This device uses cold Caesium atoms manipulated by stimulated Raman transitions (Berman, 1997). As this setup is sensitive to both acceleration and rotation, two counter-propagating beams of cold atoms are used to discriminate between the two contributions. The last experimental results will be presented here

Conference on Precision Electromagnetic Measurements•Jun 1, 2004•1 citation

High resolution rotation sensor based on cold Rubidium atoms

Michael Gilowski, Christian Schubert, Thijs Wendrich +4 more

We report on our compact transportable cold atom inertial sensor for precision sensing of rotations. The sensor consists of a dual Mach-Zehnder type atom interferometer operating with laser-cooled87Rb. Raman processes are employed to coherently manipulate the matter waves. We present the latest inertial sensitive interferometer measurements and discuss the road map to reach the full potential of the sensor featuring a sensitivity of a few nrad/s/radic(Hz).

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2009•3 citations

Demonstration of a Sagnac-Type Cold Atom Interferometer with Stimulated Raman Transitions

Wang Ping, Runbing Li, Hui Yan +2 more

Cold-matter-wave Sagnac interferometers possess many advantages over their thermal atomic beam counterparts when they are used as precise inertial sensors. We report a realization of a Sagnac-type interferometer with cold atoms. Cold rubidium atoms are prepared in a magneto-optical trap and are pushed by resonant laser pulse to form slow atomic beam. In the interference region, atomic wave packets are coherently manipulated using π/2−π−π/2 Raman pulse sequences. Interference fringes with maximum contrast of 37% are observed experimentally.

Chinese Physics Letters•Jan 1, 2007•23 citations

High-Sensitivity Absolute Atomic Gravimeter

Christine Guerlin, Tristan Farah, Anne Louchet-Chauvet +2 more

Cold atom free-fall interferometers now realize state-of-the-art precision inertial sensors, opening perspectives towards embedded devices for applications and fundamental physics tests on earth and in space. The acceleration of gravity can be measured in a stimulated Raman transition interferometer where the acceleration under gravity of a cloud of freely falling atoms is sensed by three Raman pulses allowing to split, reflect and interfere atomic wave packets [1]. The gravimeter developped at SYRTE allows to measure the acceleration of gravity at state-of-the-art performances compared to the best classical absolute gravimeters, with a sensitivity of 2×10−8g over 1s and an exactitude of 5×10−9 g [2]. This exactitude is currently limited by wavefront aberrations of the lasers, sampled by residual transverse trajectories of the molasse-cooled cloud over the free fall. Unbalanced transverse trajectories will also bias the measurement due to Coriolis effect [3]. We will investigate the use of a colder atom source to reduce these systematic effects, by implementing Bose-Einstein condensation of the initial cloud, allowing both better position control and better focusing of our source.

Research in Optical Sciences•Jan 1, 2012•0 citations

A continuous cold atomic beam interferometer

Hongbo Xue, Yanying Feng, Shu Chen +4 more

We demonstrate an atom interferometer that uses a laser-cooled continuous beam of 87Rb atoms having velocities of 10–20 m/s. With spatially separated Raman beams to coherently manipulate the atomic wave packets, Mach–Zehnder interference fringes are observed at an interference distance of 2L = 19 mm. The apparatus operates within a small enclosed area of 0.07 mm2 at a bandwidth of 190 Hz with a deduced sensitivity of 7.8×10−5 rad/s/Hz for rotations. Using a low-velocity continuous atomic source in an atom interferometer enables high sampling rates and bandwidths without sacrificing sensitivity and compactness, which are important for applications in real dynamic environments.

arXiv:1402.3822•Journal of Applied Physics•Mar 2, 2015•39 citations

Building a sensitive atom interferometer for navigation

Xiaxi Cheng

The presented thesis describes the setting up of an inertial sensitive atom interferometer for navigation using Rubidium 87 atoms, which is able to perform horizontal acceleration measurement. An ultra-high vacuum interferometer chamber is designed and built. The cold atoms are prepared in a compact 2D MOT setup and loaded into the main MOT. These atoms are then cooled down to few K and prepared in a magnetically insensitive ground state using a sequence of optical and microwave pulses, after which atoms are selected in a narrow band of the velocity. A three-pulse Mach-Zehnder ( pi/2 -pi-pi/2) interferometer using stimulated Raman transitions is used to measure the horizontal acceleration. To improve the sensitivity to acceleration, the fringe contrast of the interferometer requires to be optimised. By investigating the intensity profile of the Raman beams using atoms, a procedure is developed to operate the interferometer in an improved condition, which is able to enhance the fringe contrast by a factor of 3. This procedure improves the shot-to-shot sensitivity of the interferometer below 5 um/s^2. In addition, the atom interferometer is compared with a classical state-of-the-art accelerometer.

•Sep 1, 2019•2 citations
We build a cold atom interferometer to be used as high precision inertial sensor. Our setup is sensitive both to rotations and accelerations. The interferometer configuration is similar to an optical Mach-Zehnder interferometer, and it uses stimulated Raman transitions to manipulate the atomic wave packets (total interferometer time of 90 ms).
Cold-matter-wave Sagnac interferometers possess many advantages over their thermal atomic beam counterparts when they are used as precise inertial sensors. We report a realization of a Sagnac-type interferometer with cold atoms. Cold rubidium atoms are prepared in a magneto-optical trap and are pushed by resonant laser pulse to form slow atomic beam. In the interference region, atomic wave packets are coherently manipulated using π/2−π−π/2 Raman pulse sequences. Interference fringes with maximum contrast of 37% are observed experimentally.
Cold atom free-fall interferometers now realize state-of-the-art precision inertial sensors, opening perspectives towards embedded devices for applications and fundamental physics tests on earth and in space. The acceleration of gravity can be measured in a stimulated Raman transition interferometer where the acceleration under gravity of a cloud of freely falling atoms is sensed by three Raman pulses allowing to split, reflect and interfere atomic wave packets [1]. The gravimeter developped at SYRTE allows to measure the acceleration of gravity at state-of-the-art performances compared to the best classical absolute gravimeters, with a sensitivity of 2×10−8g over 1s and an exactitude of 5×10−9 g [2]. This exactitude is currently limited by wavefront aberrations of the lasers, sampled by residual transverse trajectories of the molasse-cooled cloud over the free fall. Unbalanced transverse trajectories will also bias the measurement due to Coriolis effect [3]. We will investigate the use of a colder atom source to reduce these systematic effects, by implementing Bose-Einstein condensation of the initial cloud, allowing both better position control and better focusing of our source.
We demonstrate an atom interferometer that uses a laser-cooled continuous beam of 87Rb atoms having velocities of 10–20 m/s. With spatially separated Raman beams to coherently manipulate the atomic wave packets, Mach–Zehnder interference fringes are observed at an interference distance of 2L = 19 mm. The apparatus operates within a small enclosed area of 0.07 mm2 at a bandwidth of 190 Hz with a deduced sensitivity of 7.8×10−5 rad/s/Hz for rotations. Using a low-velocity continuous atomic source in an atom interferometer enables high sampling rates and bandwidths without sacrificing sensitivity and compactness, which are important for applications in real dynamic environments.
The presented thesis describes the setting up of an inertial sensitive atom interferometer for navigation using Rubidium 87 atoms, which is able to perform horizontal acceleration measurement. An ultra-high vacuum interferometer chamber is designed and built. The cold atoms are prepared in a compact 2D MOT setup and loaded into the main MOT. These atoms are then cooled down to few K and prepared in a magnetically insensitive ground state using a sequence of optical and microwave pulses, after which atoms are selected in a narrow band of the velocity. A three-pulse Mach-Zehnder ( pi/2 -pi-pi/2) interferometer using stimulated Raman transitions is used to measure the horizontal acceleration. To improve the sensitivity to acceleration, the fringe contrast of the interferometer requires to be optimised. By investigating the intensity profile of the Raman beams using atoms, a procedure is developed to operate the interferometer in an improved condition, which is able to enhance the fringe contrast by a factor of 3. This procedure improves the shot-to-shot sensitivity of the interferometer below 5 um/s^2. In addition, the atom interferometer is compared with a classical state-of-the-art accelerometer.