IEEE Transactions on Applied Superconductivity

Sub-picosecond measurement of time intervals using single flux quantum electronics

Peter A. Rosenthal

Published Mar 1, 1993• 4 citations
Publisher

Abstract

A single-flux-quantum (SFQ) pulse coincidence detector based on resistively shunted nonhysteretic Josephson junctions was designed and simulated. The coincidence detector generates an SFQ pulse when the delay between the arrival of SFQ pulses at its two inputs is less than the coincidence threshold. Simulations indicate that the minimum coincidence threshold time can be as short as 400+or-200 fs, assuming Josephson junction characteristic voltages of 1 mV, overdamped dynamics, and 4.2 K operating temperatures. Circuit architectures exploiting this gate are suggested. Estimates of the effects of thermal noise on resolution are presented, indicating the potential for various time-domain measurements with subpicosecond resolution.< >

DOI
10.1109/77.233971

Related papers

Direct measurements of propagation delay of single-flux-quantum circuits by time-to-digital converters

Kazunori Nakamiya, Nobuyuki Yoshikawa, Akira Fujimaki +2 more

Direct measurements of propagation delay of single-flux-quantum (SFQ) circuits were performed using SFQ double-oscillator time-to-digital converters. The propagation delay of several SFQ logic gates in our cell library named CONNECT were measured in picosecond resolution. Small discrepancy in the propagation delay of picosecond level was observed between measurement and circuit simulation results. The discrepancy is well explained assuming the parasitic inductance around shunt resistors of Josephson junctions.

IEICE Electronics Express•Jan 1, 2008•5 citations

Current Resolution of a Single-Flux-Quantum Readout Circuit Based on Current-to-Time Conversion Toward a Flux Qubit System

Shoichi Nakamura, H. Numabe, Ali Bozbey +1 more

We study a single-shot single-flux-quantum (SFQ) readout circuit based on current-to-time conversion for superconducting flux qubits. Circulating currents representing states of a qubit were converted to propagation delay time of SFQ pulses, and then detected by a time discriminator. The key parameter which determines the availability of single-shot readout is current resolution. We evaluated the current resolution by measuring the gray zone which was defined as the transition width in the output probability of the current-to-time converter with 1000 trials for each value of an input current. For reducing unwanted effects on the qubit, shunt resistors are required to be removed for Josephson junctions in the readout circuit. We designed two readout circuits for comparison, the circuit composed of shunted junctions and that of unshunted junctions. Gray zones were measured to be 4.8$\mu{\rm A}$for unshunted junctions and 2.2$\mu{\rm A}$for the shunted ones at 4.2 K. These gray zones may originate from Johnson noise. Operation at a reduced temperature and employment of a likelihood decision circuit will lead to reduced gray zone, i.e., improved current resolution sufficient for single-shot readout.

IEEE Transactions on Applied Superconductivity•Jun 1, 2009•15 citations

Design of integrated SSPD-SFQ two-photon coincidence correlator

I. Komissarov, Amir Jafari Salim, Oleg A. Mukhanov +3 more

We present a single-flux-quantum (SFQ) based digital correlator to trace independent signals from two superconducting single-photon detectors (SSPDs) triggering its inputs. In our design two SSPDs are magnetically coupled to inputs of a readout system where direct current (DC)-to-SFQ converters are used to convert transient SSPD output pulses, triggered by detection of single-photon events, to SFQ pulses. The coincidence verification of SFQ pulses, generated by the two DC-to-SFQ converters, is performed with a modified SFQ coincidence buffer. The coincidence buffer is designed to generate an SFQ output pulse only when its both inputs are triggered simultaneously, or within a preset margin time. The output of the coincidence buffer is connected via, this time, an SFQ-to-DC converter, to a pulse counter operated at room temperature. We performed extensive simulations of both the SSPD equivalent circuit and correlator redout elements for the proposed coincidence scheme, using a WRSpice and PSCAN2 simulation platforms that are specifically designated to model Josephson junctions and widely used to simulate operation of the SFQ circuitry. In particular, we investigated our coincidence correlator scheme for measurements of the second-order correlation function, used to demonstrate the antibunching effect in the single-photon detection of non-classical light.

Quantum Optics and Photon Counting•Jun 6, 2023•2 citations

Experimental realization of a resistive single flux quantum logic circuit

V. P. Koshelets, K. K. Likharev, V. V. Migulin +5 more

An integrated circuit including all basic components of the recently suggested Resistive Single Flux Quantum (RSFQ) logic family has been designed, fabricated and tested successfully. The circuit includes a generator of periodic SFQ pulses, four buffer/amplifier stages for splitting, channeling and regeneration of the pulses, a detector/load stage, and universal RSFQ logic gate (here performing the NOT function). The 10μm design rule circuit employs 13 active Nb - Al2O3- Nb Josephson junctions with the critical current density ∼ 0.5 kA/cm2. externally shunted by Mo resistors with R 1 Ohm. The shunting provided critical damping of the junctions (\beta_{c}\lsim 1) and reasonable (\sim 500 \muV) IcR product. The circuit operation has been tested by measurement of dc voltages\bar{V}_{i}across various Josephson junctions as functions of the dc current through the pulse generator. Correct and stable operation of the circuit for the clock frequencies from 0 to ∼30 GHz has been demonstrated.

IEEE Transactions on Magnetics•Mar 1, 1987•37 citations

Superconducting coincidence photon detector with short timing jitter

Shigehito Miki, Shigeyuki Miyajima, Masahiro Yabuno +7 more

We demonstrate the operation of a coincidence photon detector with a short timing jitter consisting of two superconducting nanowire single photon detectors (SSPDs) and a single flux quantum (SFQ) circuit. By utilizing the timing discrimination capability of the SFQ coincidence circuit, the full width at half maximum timing jitter of the entire coincidence photon detector was evaluated as 32.3 ps, which is 36 ps less than that of the standard commercial time correlated single photon counting module, and the timing jitter of the SSPD was estimated as ∼15 ps. Owing to the short timing jitter characteristics, our coincidence photon detector could correctly capture the effect of pulse-width broadening by insertion of an optical bandpass filter. We have also demonstrated that our coincidence photon detection clearly shows Hong-Ou-Mandel interference with a weak coherent pulse. These results are a crucial step to realizing high timing resolution coincidence measurements, ushering in a technology for timing measurement based multi-photon quantum interference.

Applied Physics Letters•Jun 25, 2018•24 citations

Timing Jitter Measurement in Single-Flux-Quantum Circuits Based on Time-to-Digital Converters With High Time-Resolution

Terabe Masayoshi, Sekiya Akito, Takahiro Yamada +1 more

We evaluated timing jitter based on a time-to-digital converter (TDC) having sub-pico seconds time resolution. The measured jitter at liquid helium temperature was 65 fs for an optimally damped simple junction composing a conventional Josephson transmission line fabricated with the NEC standard process. The temperature dependence and shunt resistance dependence of jitter indicate that the jitter originates from thermal noise generated at the shunt resistor of the junction. We also found that the timing jitter of a balanced comparator is much larger than that of a JTL. The jitter of a balanced comparator is independent of temperature. This means that the jitter of a balanced comparator does not arise from thermal noise.

IEEE Transactions on Applied Superconductivity•Jun 1, 2007•26 citations
A single-flux-quantum (SFQ) pulse coincidence detector based on resistively shunted nonhysteretic Josephson junctions was designed and simulated. The coincidence detector generates an SFQ pulse when the delay between the arrival of SFQ pulses at its two inputs is less than the coincidence threshold. Simulations indicate that the minimum coincidence threshold time can be as short as 400+or-200 fs, assuming Josephson junction characteristic voltages of 1 mV, overdamped dynamics, and 4.2 K operating temperatures. Circuit architectures exploiting this gate are suggested. Estimates of the effects of thermal noise on resolution are presented, indicating the potential for various time-domain measurements with subpicosecond resolution.< >
Direct measurements of propagation delay of single-flux-quantum (SFQ) circuits were performed using SFQ double-oscillator time-to-digital converters. The propagation delay of several SFQ logic gates in our cell library named CONNECT were measured in picosecond resolution. Small discrepancy in the propagation delay of picosecond level was observed between measurement and circuit simulation results. The discrepancy is well explained assuming the parasitic inductance around shunt resistors of Josephson junctions.
We study a single-shot single-flux-quantum (SFQ) readout circuit based on current-to-time conversion for superconducting flux qubits. Circulating currents representing states of a qubit were converted to propagation delay time of SFQ pulses, and then detected by a time discriminator. The key parameter which determines the availability of single-shot readout is current resolution. We evaluated the current resolution by measuring the gray zone which was defined as the transition width in the output probability of the current-to-time converter with 1000 trials for each value of an input current. For reducing unwanted effects on the qubit, shunt resistors are required to be removed for Josephson junctions in the readout circuit. We designed two readout circuits for comparison, the circuit composed of shunted junctions and that of unshunted junctions. Gray zones were measured to be 4.8μA\mu{\rm A}μAfor unshunted junctions and 2.2μA\mu{\rm A}μAfor the shunted ones at 4.2 K. These gray zones may originate from Johnson noise. Operation at a reduced temperature and employment of a likelihood decision circuit will lead to reduced gray zone, i.e., improved current resolution sufficient for single-shot readout.
We present a single-flux-quantum (SFQ) based digital correlator to trace independent signals from two superconducting single-photon detectors (SSPDs) triggering its inputs. In our design two SSPDs are magnetically coupled to inputs of a readout system where direct current (DC)-to-SFQ converters are used to convert transient SSPD output pulses, triggered by detection of single-photon events, to SFQ pulses. The coincidence verification of SFQ pulses, generated by the two DC-to-SFQ converters, is performed with a modified SFQ coincidence buffer. The coincidence buffer is designed to generate an SFQ output pulse only when its both inputs are triggered simultaneously, or within a preset margin time. The output of the coincidence buffer is connected via, this time, an SFQ-to-DC converter, to a pulse counter operated at room temperature. We performed extensive simulations of both the SSPD equivalent circuit and correlator redout elements for the proposed coincidence scheme, using a WRSpice and PSCAN2 simulation platforms that are specifically designated to model Josephson junctions and widely used to simulate operation of the SFQ circuitry. In particular, we investigated our coincidence correlator scheme for measurements of the second-order correlation function, used to demonstrate the antibunching effect in the single-photon detection of non-classical light.
An integrated circuit including all basic components of the recently suggested Resistive Single Flux Quantum (RSFQ) logic family has been designed, fabricated and tested successfully. The circuit includes a generator of periodic SFQ pulses, four buffer/amplifier stages for splitting, channeling and regeneration of the pulses, a detector/load stage, and universal RSFQ logic gate (here performing the NOT function). The 10μm design rule circuit employs 13 active Nb - Al2O3- Nb Josephson junctions with the critical current density ∼ 0.5 kA/cm2. externally shunted by Mo resistors with R 1 Ohm. The shunting provided critical damping of the junctions (\beta_{c}\lsim 1) and reasonable (\sim 500 \muV) IcR product. The circuit operation has been tested by measurement of dc voltages\bar{V}_{i}across various Josephson junctions as functions of the dc current through the pulse generator. Correct and stable operation of the circuit for the clock frequencies from 0 to ∼30 GHz has been demonstrated.
We demonstrate the operation of a coincidence photon detector with a short timing jitter consisting of two superconducting nanowire single photon detectors (SSPDs) and a single flux quantum (SFQ) circuit. By utilizing the timing discrimination capability of the SFQ coincidence circuit, the full width at half maximum timing jitter of the entire coincidence photon detector was evaluated as 32.3 ps, which is 36 ps less than that of the standard commercial time correlated single photon counting module, and the timing jitter of the SSPD was estimated as ∼15 ps. Owing to the short timing jitter characteristics, our coincidence photon detector could correctly capture the effect of pulse-width broadening by insertion of an optical bandpass filter. We have also demonstrated that our coincidence photon detection clearly shows Hong-Ou-Mandel interference with a weak coherent pulse. These results are a crucial step to realizing high timing resolution coincidence measurements, ushering in a technology for timing measurement based multi-photon quantum interference.
We evaluated timing jitter based on a time-to-digital converter (TDC) having sub-pico seconds time resolution. The measured jitter at liquid helium temperature was 65 fs for an optimally damped simple junction composing a conventional Josephson transmission line fabricated with the NEC standard process. The temperature dependence and shunt resistance dependence of jitter indicate that the jitter originates from thermal noise generated at the shunt resistor of the junction. We also found that the timing jitter of a balanced comparator is much larger than that of a JTL. The jitter of a balanced comparator is independent of temperature. This means that the jitter of a balanced comparator does not arise from thermal noise.