Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Symposium on Frequency Standards and Metrology

COHERENT POPULATION TRAPPING AND INTENSITY OPTICAL PUMPING: ON THEIR USE IN ATOMIC FREQUENCY STANDARDS

Jacques Vanier, Martin W. Levine, DANIEL JANSSEN, MICHAEL DELANEY

Published May 1, 2002• 10 citations
Publisher

Abstract

The paper summarizes the relative advantages and disadvantages of Coherent Population Trapping (CPT) and Intensity Optical Pumping (IOP) for the implementation of a passive atomic frequency standard. The paper outlines the basic principles common to both CPT and IOP when using laser optical pumping, and makes explicit their similarities and their differences. The paper describes recent experimental results obtained in the same cell on the characteristics of the CPT and IOP 87 Rb -hyperfme resonance line.

DOI
10.1142/9789812777713_0019

Related papers

On the use of intensity optical pumping and coherent population trapping techniques in the implementation of atomic frequency standards

Jaques Vanier, M. W. Levine, D. Janssen +1 more

The paper summarizes the relative advantages and disadvantages of coherent population trapping (CPT) or intensity optical pumping (IOP) for the implementation of a passive atomic frequency standard using the isotope /sup 87/Rb. This paper outlines the basic principles common to both CPT and IOP when using laser optical pumping, and makes explicit their similarities and their differences. This paper describes experimental results obtained in the same cell on the characteristics of the CPT and IOP /sup 87/Rb-hyperfine-resonance line. The measurements showed that the signal contrast is larger in CPT than in IOP for the same resulting line width; the light shift is smaller in CPT than in IOP, and is easier to control; in principle, a passive frequency standard based on CPT has a smaller size than that based on IOP, due to the absence of a microwave cavity. Conclusions on overall expectations for the future of such frequency standards are drawn.

IEEE Transactions on Instrumentation and Measurement•Jun 1, 2003•56 citations

Coherent population trapping for the realization of a small, stable, atomic clock

Jaques Vanier

The coherent population trapping phenomenon (CPT) has created interesting avenues in the practical realization of atomic frequency standards using laser optical pumping. In practice two different types of standards can be implemented: a passive clock based on the dark state created in the ensemble by the CPT phenomenon and a maser based on the ground state oscillating magnetization induced by the same phenomenon. The paper describes the basic physics involved in the approach and summarizes the progress made thus far in the practical implementation of such frequency standards.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jun 25, 2003•12 citations

Practical Realization of a Passive Coherent Population Trapping Frequency Standard

Jaques Vanier, M. W. Levine, S. Kendig +3 more

The paper outlines the practical realization and characteristics of a small, totally autonomous passive frequency standard based on the coherent population trapping (CPT) phenomenon. The frequency standard, including physical characteristics, block diagrams of the optical control CPT resonance system and of the digital control electronics, is described. The characteristics of the frequency standard relative to general functionality and frequency stability are given, as measured on several units.

IEEE Transactions on Instrumentation and Measurement•Nov 22, 2005•40 citations

The Passive Optically Pumped Rb Frequency Standard: the Laser Approach

Jaques Vanier, C. Mandache

This paper provides an overview of the efforts accomplished during the last few decades in the attempt of implementing a Rb-cell frequency standard using optical-microwave double resonance and laser optical pumping. The results of a new analysis based on a three-level model are summarized. Pumping rates, line widths, light shifts, cell radiation transmission and resonance signal size relative to background are calculated making use of the coherence property of the pumping laser. The expected frequency stability is calculated. The results obtained by several research groups are reviewed, compared to the analysis, and evaluated in the context of the implementation of a practical frequency standard. It is concluded that compromises must be made between the goal of obtaining a frequency stability close to the shot noise limit and that of minimizing complexity. Two directions that address such compromises are outlined.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2007•7 citations

Passive atomic frequency standard based on coherent population trapping in ^87Rb using injection-locked lasers

Han Seb Moon, Sang Eon Park, Young‐Ho Park +2 more

We present a microwave frequency standard based on coherent population trapping (CPT) in the 87Rb D1 line. The CPT spectrum is obtained using two Raman lasers with a 6.8 GHz frequency offset by injection locking of a master laser to a slave laser. We have constructed an atomic clock employing a 5 cm long Rb vapor cell confined with 6.67 kPa neon buffer gas at 70 °C. Using this system, we improve the CPT contrast through the elimination of undesired off-resonant fields created by the direct modulation method. We measured the frequency shift of the CPT signal as a function of the temperature of the Rb cell and estimated it to be approximately 1.3 ×10−9/K. The frequency of a 10 MHz crystal oscillator has been stabilized to the CPT spectrum between the two ground states in 87Rb. The relative frequency stability is approximately 2.3×10−12 for an average time of 68 s.

Journal of the Optical Society of America B•Nov 1, 2006•23 citations

Properties of Rb CPT Atomic Clock at Subharmonic Microwave Modulation Frequencies

Daba A. Radnatarov, Sergey M Kobtsev, Valeriy Andryushkov +3 more

This letter presents for the first time a systematic study of an atomic frequency standard based on coherent population trapping (CPT) effect in87Rb vapour optically pumped with a multifrequency laser radiation formed with sidebands of a single-frequency laser whose injection current is modulated at a subharmonic frequency (1/2-1/6) relative to the frequency of hyperfine ground state splitting. Measured are the CPT resonance parameters and the atomic clock short-term stability at different subharmonic frequencies of microwave modulation. The possibility of CPT resonance light shift suppression is experimentally demonstrated at modulation frequencies between 1/3 and 1/5 of the resonant frequency for continuous wave optical pumping of the87Rb vapour D1 line. Analyzed are the capabilities and potential of reduced energy consumption of atomic clocks when CPT resonance in rubidium vapour is excited at subharmonic modulation frequencies.

IEEE photonics journal•Jun 26, 2019•2 citations
The paper summarizes the relative advantages and disadvantages of Coherent Population Trapping (CPT) and Intensity Optical Pumping (IOP) for the implementation of a passive atomic frequency standard. The paper outlines the basic principles common to both CPT and IOP when using laser optical pumping, and makes explicit their similarities and their differences. The paper describes recent experimental results obtained in the same cell on the characteristics of the CPT and IOP 87 Rb -hyperfme resonance line.
The paper summarizes the relative advantages and disadvantages of coherent population trapping (CPT) or intensity optical pumping (IOP) for the implementation of a passive atomic frequency standard using the isotope /sup 87/Rb. This paper outlines the basic principles common to both CPT and IOP when using laser optical pumping, and makes explicit their similarities and their differences. This paper describes experimental results obtained in the same cell on the characteristics of the CPT and IOP /sup 87/Rb-hyperfine-resonance line. The measurements showed that the signal contrast is larger in CPT than in IOP for the same resulting line width; the light shift is smaller in CPT than in IOP, and is easier to control; in principle, a passive frequency standard based on CPT has a smaller size than that based on IOP, due to the absence of a microwave cavity. Conclusions on overall expectations for the future of such frequency standards are drawn.
The coherent population trapping phenomenon (CPT) has created interesting avenues in the practical realization of atomic frequency standards using laser optical pumping. In practice two different types of standards can be implemented: a passive clock based on the dark state created in the ensemble by the CPT phenomenon and a maser based on the ground state oscillating magnetization induced by the same phenomenon. The paper describes the basic physics involved in the approach and summarizes the progress made thus far in the practical implementation of such frequency standards.
This paper provides an overview of the efforts accomplished during the last few decades in the attempt of implementing a Rb-cell frequency standard using optical-microwave double resonance and laser optical pumping. The results of a new analysis based on a three-level model are summarized. Pumping rates, line widths, light shifts, cell radiation transmission and resonance signal size relative to background are calculated making use of the coherence property of the pumping laser. The expected frequency stability is calculated. The results obtained by several research groups are reviewed, compared to the analysis, and evaluated in the context of the implementation of a practical frequency standard. It is concluded that compromises must be made between the goal of obtaining a frequency stability close to the shot noise limit and that of minimizing complexity. Two directions that address such compromises are outlined.
We present a microwave frequency standard based on coherent population trapping (CPT) in the 87Rb D1 line. The CPT spectrum is obtained using two Raman lasers with a 6.8 GHz frequency offset by injection locking of a master laser to a slave laser. We have constructed an atomic clock employing a 5 cm long Rb vapor cell confined with 6.67 kPa neon buffer gas at 70 °C. Using this system, we improve the CPT contrast through the elimination of undesired off-resonant fields created by the direct modulation method. We measured the frequency shift of the CPT signal as a function of the temperature of the Rb cell and estimated it to be approximately 1.3 ×10−9/K. The frequency of a 10 MHz crystal oscillator has been stabilized to the CPT spectrum between the two ground states in 87Rb. The relative frequency stability is approximately 2.3×10−12 for an average time of 68 s.
This letter presents for the first time a systematic study of an atomic frequency standard based on coherent population trapping (CPT) effect in87Rb vapour optically pumped with a multifrequency laser radiation formed with sidebands of a single-frequency laser whose injection current is modulated at a subharmonic frequency (1/2-1/6) relative to the frequency of hyperfine ground state splitting. Measured are the CPT resonance parameters and the atomic clock short-term stability at different subharmonic frequencies of microwave modulation. The possibility of CPT resonance light shift suppression is experimentally demonstrated at modulation frequencies between 1/3 and 1/5 of the resonant frequency for continuous wave optical pumping of the87Rb vapour D1 line. Analyzed are the capabilities and potential of reduced energy consumption of atomic clocks when CPT resonance in rubidium vapour is excited at subharmonic modulation frequencies.