Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Applied Physics

Microwave field distribution in superconducting thin film devices

D. Quenter, T. Doderer, Rudolf Peter Huebener

Published Sep 15, 1996• 2 citations
Publisher

Abstract

We measured the spatial distribution of microwave fields and dissipative surface currents in various passive and active superconducting thin-film devices during their operation at a temperature of about 4 K. We used low-temperature scanning electron microscopy which offers a spatial resolution of about 1 μm and we present sample response models for interpreting the imaging results. Such investigations may have important consequences for the improvement of the design and preparation of superconducting thin-film microwave devices.

DOI
10.1063/1.363230

Related papers

Spatially resolved studies of the microwave properties of superconducting devices

D. Quenter, S. Stehle, T. Doderer +8 more

Low temperature scanning electron microscopy (LTSEM) offers the possibility for spatially resolved investigations of microwave properties of single Josephson junctions, superconducting striplines, resonators, and complex cryoelectric circuits during their operation. The spatial resolution of about 1 μm is at least two orders of magnitude better than the typical wavelength (≳100 μm in the elements) in the frequency range of interest (50–500 GHz). We demonstrate that LTSEM is a well suited tool for the experimental investigation of superconducting microwave devices and cryoelectronic circuits.

Applied Physics Letters•Oct 11, 1993•11 citations

Imaging local sources of intermodulation in superconducting microwave devices

Alexander P. Zhuravel, Alexey Vladimirovich Ustinov, D. Abraimov +1 more

This work presents new experimental results on low-temperature (LT) characterization of local RF properties of passive superconducting (SC) microwave devices using a novel laser scanning microscope (LSM). In this technique, a modulated laser beam is focused onto and scanned over the surface of a resonant SC device to probe the spatial distribution of RF current. The highly localized photo-induced change of the kinetic inductance of the SC device produces both a shift of the resonant frequency f/sub 0/ and change of the quality factor Q. An image of these changes is recorded as the laser spot is scanned over the device. We present the first measurements of spatially resolved intermodulation response in a high temperature superconducting (HTS) co-planar waveguide resonator, opening up a new window into the local origins of nonlinearity in the HTS materials.

arXiv:cond-mat/0211191•IEEE Transactions on Applied Superconductivity•Jun 1, 2003•21 citations

Imaging sub-millimeter waves in planar cryoelectronic circuits by scanning laser microscopy

Dmytro V Abraimov, Alexey Vladimirovich Ustinov, S. V. Shitov

Low temperature scanning laser microscopy (LTSLM) is demonstrated to be capable of imaging sub-THz electromagnetic fields in cryoelectronic integrated structures. This method allows one to evaluate the spatial distribution of time-averaged field amplitudes with a resolution of about one micrometer for samples with characteristic dimensions of order millimeters. Using LTSLM, cryoelectronic devices with both passive and active superconducting elements can be characterized. Local heating of superconducting structures by a laser beam introduces extra loss for the propagating and standing sub-millimeter waves. We present LTSLM images of two-dimensional 400 to 500 standing GHz wave patterns in integrated superconducting receiver chips.

IEEE Transactions on Applied Superconductivity•Mar 1, 2001•3 citations

Measurement of the current‐density distribution in high‐temperature superconducting microstrip by means of kinetic‐inductance photoresponse (invited paper)

Harvey S. Newman, James C. Culbertson

Abstract We report a technique for measuring the spatial profile of microwave‐frequency currents in resonant thin‐film superconducting microstrip devices operated near resonance. We probe the patterned superconducting device as a function of position by scanning a modulated light beam across the region to be probed. With the light focused to a spot size much smaller than the microstrip width, we have measured the current density distribution as a function of position across the width of the strip. Using an elementary model for the superconducting current density distribution, we fit an effective penetration depth at the edge of the microstrip. © 1993 John Wiley & Sons, Inc.

Microwave and Optical Technology Letters•Oct 1, 1993•15 citations

A noncontact cryogenic microwave measurement system for superconducting device characterization

Alp Tugrul Findikoglu, T. Nakamura, Hitoki Tokuda +1 more

A noncontact cryogenic microwave measurement system has been developed for the characterization of passive and active superconducting devices by means of an unloaded quality factor measurement technique. The measurement system was designed specifically for the characterization of planar thin film resonant structures as a function of temperature (4–300 K), frequency (100 MHz–26.5 GHz), and dc voltage bias (≤100 V). It has been used for basic device studies of novel active superconducting lumped components made of metal-oxide superconductor/insulator heterostructures.

Review of Scientific Instruments•Sep 1, 1994•0 citations

Effects of the thin-film thickness on superconducting NbTi microwave resonators for on-chip cryogenic thermometry

André Chatel, Roberto Russo, Luca Mazzone +5 more

Abstract Superconducting microwave resonators have recently gained a primary importance in the development of cryogenic applications, such as circuit quantum electrodynamics, electron spin resonance spectroscopy and particles detection for high-energy physics and astrophysics. In this work, we investigate the influence of the film thickness on the temperature response of microfabricated Nb 50 Ti 50 superconducting resonators. S-shaped split ring resonators (S-SRRs), approximately 20 nm to 150 nm thick, are designed to be electromagnetically coupled with standard Cu coplanar waveguides (CPWs) and their microwave properties are characterised at temperatures below 10 K . The combined contributions of the kinetic inductance L K ( T ) increase and the decreasing loaded quality factor Q L , for thinner films, induce an optimum condition on the temperature sensitivity and resolution of the resonators. A noise equivalent temperature as low as ( 0.53 ± 0.09 ) μ K Hz − 1 / 2 , at 1 Hz , is reported for 100 nm thick resonators at 4.2 K . We also asses the possibility of implementing a multiplexed frequency readout, allowing for the simultaneous temperature tracking of several sensors along a single CPW. Such results demonstrate the possibility to perform a distributed cryogenic temperature monitoring, with a sub- μ K resolution. Thus, the application of superconducting S-SRRs, eventually benefiting from an even higher

arXiv:2503.20416•Superconductor Science and Technology•Dec 1, 2025•1 citation
We measured the spatial distribution of microwave fields and dissipative surface currents in various passive and active superconducting thin-film devices during their operation at a temperature of about 4 K. We used low-temperature scanning electron microscopy which offers a spatial resolution of about 1 μm and we present sample response models for interpreting the imaging results. Such investigations may have important consequences for the improvement of the design and preparation of superconducting thin-film microwave devices.
Low temperature scanning electron microscopy (LTSEM) offers the possibility for spatially resolved investigations of microwave properties of single Josephson junctions, superconducting striplines, resonators, and complex cryoelectric circuits during their operation. The spatial resolution of about 1 μm is at least two orders of magnitude better than the typical wavelength (≳100 μm in the elements) in the frequency range of interest (50–500 GHz). We demonstrate that LTSEM is a well suited tool for the experimental investigation of superconducting microwave devices and cryoelectronic circuits.
This work presents new experimental results on low-temperature (LT) characterization of local RF properties of passive superconducting (SC) microwave devices using a novel laser scanning microscope (LSM). In this technique, a modulated laser beam is focused onto and scanned over the surface of a resonant SC device to probe the spatial distribution of RF current. The highly localized photo-induced change of the kinetic inductance of the SC device produces both a shift of the resonant frequency f/sub 0/ and change of the quality factor Q. An image of these changes is recorded as the laser spot is scanned over the device. We present the first measurements of spatially resolved intermodulation response in a high temperature superconducting (HTS) co-planar waveguide resonator, opening up a new window into the local origins of nonlinearity in the HTS materials.
Low temperature scanning laser microscopy (LTSLM) is demonstrated to be capable of imaging sub-THz electromagnetic fields in cryoelectronic integrated structures. This method allows one to evaluate the spatial distribution of time-averaged field amplitudes with a resolution of about one micrometer for samples with characteristic dimensions of order millimeters. Using LTSLM, cryoelectronic devices with both passive and active superconducting elements can be characterized. Local heating of superconducting structures by a laser beam introduces extra loss for the propagating and standing sub-millimeter waves. We present LTSLM images of two-dimensional 400 to 500 standing GHz wave patterns in integrated superconducting receiver chips.
Abstract We report a technique for measuring the spatial profile of microwave‐frequency currents in resonant thin‐film superconducting microstrip devices operated near resonance. We probe the patterned superconducting device as a function of position by scanning a modulated light beam across the region to be probed. With the light focused to a spot size much smaller than the microstrip width, we have measured the current density distribution as a function of position across the width of the strip. Using an elementary model for the superconducting current density distribution, we fit an effective penetration depth at the edge of the microstrip. © 1993 John Wiley & Sons, Inc.
A noncontact cryogenic microwave measurement system has been developed for the characterization of passive and active superconducting devices by means of an unloaded quality factor measurement technique. The measurement system was designed specifically for the characterization of planar thin film resonant structures as a function of temperature (4–300 K), frequency (100 MHz–26.5 GHz), and dc voltage bias (≤100 V). It has been used for basic device studies of novel active superconducting lumped components made of metal-oxide superconductor/insulator heterostructures.
Abstract Superconducting microwave resonators have recently gained a primary importance in the development of cryogenic applications, such as circuit quantum electrodynamics, electron spin resonance spectroscopy and particles detection for high-energy physics and astrophysics. In this work, we investigate the influence of the film thickness on the temperature response of microfabricated Nb 50 Ti 50 superconducting resonators. S-shaped split ring resonators (S-SRRs), approximately 20 nm to 150 nm thick, are designed to be electromagnetically coupled with standard Cu coplanar waveguides (CPWs) and their microwave properties are characterised at temperatures below 10 K . The combined contributions of the kinetic inductance L K ( T ) increase and the decreasing loaded quality factor Q L , for thinner films, induce an optimum condition on the temperature sensitivity and resolution of the resonators. A noise equivalent temperature as low as ( 0.53 ± 0.09 ) μ K Hz − 1 / 2 , at 1 Hz , is reported for 100 nm thick resonators at 4.2 K . We also asses the possibility of implementing a multiplexed frequency readout, allowing for the simultaneous temperature tracking of several sensors along a single CPW. Such results demonstrate the possibility to perform a distributed cryogenic temperature monitoring, with a sub- μ K resolution. Thus, the application of superconducting S-SRRs, eventually benefiting from an even higher