Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Transactions on Applied Superconductivity

Optical Response of a Cold-Electron Bolometer Array Integrated in a 345-GHz Cross-Slot Antenna

Michael A. Tarasov, L. S. Kuzmin, Valerian S. Edelman, Sumedh Mahashabde, P. de Bernardis

Published Oct 28, 2011• 38 citations
Publisher

Abstract

Two series/parallel arrays of ten cold-electron bolometers with superconductor-insulator-normal tunnel junctions were integrated in orthogonal ports of a cross-slot antenna. To increase the dynamic range of the receiver, all single bolometers in an array are connected in parallel for the microwave signal by capacitive coupling. To increase the output response, bolometers are connected in series for dc bias. With the measured voltage-to-temperature response of 8.8 μV/mK, absorber volume of 0.08 μm3, and output noise of about 10 nV/Hz1/2, we estimated the dark electrical noise equivalent power (NEP) as NEP = 6 * 10-18W/Hz1/2. The optical response down to NEP = 2 * 10-17W/Hz1/2was measured using a hot/cold load as a radiation source and a sample temperature down to 100 mK. The fluctuation sensitivity to the radiation source temperature is 1.3 * 10-4K/Hz1/2. A dynamic range over 43 dB was measured using a backward-wave oscillator, a variable polarization grid attenuator, and cold filters/attenuators.

DOI
10.1109/tasc.2011.2169793

Related papers

Power load dependencies of cold electron bolometer optical response at 350 ghz

Michael A. Tarasov, Valeryan S. Edel'man, Andrey B. Ermakov +2 more

Cold electron bolometers integrated with twin-slot antennas have been designed and fabricated. Optical response was measured in 0.06-0.6 K temperature range using black body radiation source at temperature 2-15 K. The responsivity of 0.3109 V/W was measured at 2.7 K radiation temperature. The estimated ultimate dark responsivity at 100 mK can approach Sv=1010 V/W and reduces down to 1.1108 V/W at 300 mK for the sample with absorber volume of 510-20 m3. At high power load levels and low temperatures the changes of tunneling current, dynamic resistance and voltage response have been explained by non-thermal energy distribution of excited electrons. Distribution of excited electrons in such system is of none-Fermi type, electrons with energies of the order of 1 K tunnel from normal metal absorber to superconductor instead of relaxing down to thermal energy kTe. This effect can reduce quantum efficiency of bolometer from hf/kTph in ideal case down to single electron per signal quantum in the high power case.

•Jan 1, 2014•0 citations

A parallel/series array of superconducting cold-electron bolometers with SIS' tunnel junctions

L. S. Kuzmin

A novel concept of the parallel/series array of Cold-Electron Bolometers (CEB) with Superconductor-Insulator-Normal (SIN) Tunnel Junctions has been proposed for matching with JFET readout. The current-biased CEBs are connected in series for DC and in parallel for HF signal. A signal is concentrated to the absorber through the capacitance of tunnel junctions and additional capacitance for coupling of superconducting islands. Due to dividing power between CEBs in the array and increasing responsivity, the noise matching could be effectively optimized and the photon Noise Equivalent Power could be easily achieved at 300 mK with a room temperature JFET readout.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jul 17, 2008•3 citations

Optical response of a titanium-based cold-electron bolometer

Ernst Otto, Michael A. Tarasov, Paul Grimes +3 more

We present experimental results on the testing of cold-electron bolometer (CEB) detectors comprised of a thin Ti film absorber and two SIN junctions integrated with a planar antenna. The CEB performance was tested in a He-3 sorption cryostat HELIOX-AC-V at bath temperatures of 280-305 mK. The optical response was measured using the hot/cold load method by flipping a Cu reflector opposite a blackbody surface inside a 3 K shield and using a thermal source with variable temperature. In the first experiment, the detector chip was mounted in an optical sample-holder whose aperture was switched towards or away from a blackbody source changing the incident radiation temperature from 3 K to 270 mK. As a result, we measured the optical response to a 3 K/270 mK radiation temperature change. The measured voltage response value for the detector integrated in a double-dipole antenna was Delta V-out = 120 mu V. This corresponds to a noise equivalent power of NEP = V-n/(dV/dP) = 3.5 x 10(-17) W Hz(-1/2), where dV/dP is the voltage to power response obtained from the incoming power estimation based on the Planck formula.

Superconductor Science and Technology•Jul 4, 2013•4 citations

Quantum Efficiency of Cold Electron Bolometer Optical Response

Michael A. Tarasov, Valerian S. Edelman, Andrey B. Ermakov +2 more

In this paper, we present the measurements of optical response dependence on power load of a Cold Electron Bolometer integrated in a twin slot antenna. These measurements are also compared to the models of the bolometer limit and the photon counter limit. The responsivity of 0.22*109V/W was measured at 0.22 pW radiation power from a black body at 3.5 K. According to our estimations, for optimized device the voltage responsivity at 100 mK electron temperature can approach S v = 1010V/W for power load below 0.1 pW and decreases down to 107V/W at 300 mK for 5 pW signal power in a sample with absorber volume of 5*10-20m3. In the case of low bath temperatures and high applied RF power the changes of tunneling current, dynamic resistance and voltage response are explained by non-thermal energy distribution of excited electrons. Distribution of excited electrons in such system at lower temperatures can be of non-Fermi type, hot electrons with energies of the order of 1 K tunnel from normal metal absorber to superconductor instead of relaxing down to thermal energy kTein absorber before tunneling. This effect can reduce quantum efficiency of the bolometer at 350 GHz from η = hf/kTph> 100 in ideal case down to single electron per absorbed photon ( η = 1) in the high power case. Methods of preserving high quantum efficiency are discussed.

IEEE Transactions on Terahertz Science and Technology•Jan 1, 2014•12 citations

Terahertz spectroscopy by Josephson oscillator and cold-electron bolometer

Michael A. Tarasov, L. S. Kuzmin, T. Claeson +2 more

For sensitive wideband spectroscopy at THz frequencies with performance better than for Fourier Transform Spectrometer, one needs a wide-range electrically tunable, narrow linewidth THz source, and a sensitive broadband detector. To obtain a low noise level of sensor we use a superconducting normal metal cold electron bolometer (CEB). A voltage response of the bolometer is 4.108 V/W and an amplifier-limited technical noise equivalent power of the bolometer is 1.25.10-17 W/Hz1/2. The wide band electrically tuned terahertz band cryogenic oscillator is a Josephson junction. Contrary to conventional Josephson junctions based on niobium, and naturally limited in frequency by energy gap of about 700 GHz, the high critical temperature YBaCuO junctions can extend this limit by an order of magnitude. At 4 K such oscillators can radiate at frequencies exceeding 2 THz. Signals received by bolometers integrated with double-dipole and log-periodic antennas and irradiated by the Josephson oscillator show in our experiments the high frequency response corresponding to an oscillation frequency of up to 1.75 THz. Such cryogenic terahertz network analyzer is suitable for low-signal spectral evaluation of cryogenic detectors, quasioptical sub-mm cryogenic filters, planar antennas with planar microwave filters, integrated structures comprising such elements, and arrays of cryogenic receivers.

•Jan 1, 2004•0 citations

Responsivity and Noise Equivalent Power of a Single Cold-Electron Bolometer

Ian Jasper Agulo, L. S. Kuzmin

We have developed a single-pixel capacitively coupled Cold-Electron Bolometer (CEB) and characterized it in the current-biased regime. The most attractive feature of the CEB is effective electron self-cooling of the absorber, which leads to a lower bolometer noise and higher dynamic range. The bolometer responsivity was measured by determining the voltage response to an applied power through the absorber from a heating current, modulated at frequencies from 35 Hz to 2 kHz. The optimum responsivity of 1.5 × 1010 V/W was measured at a modulation frequency of 35 Hz. The noise equivalent power (NEP) was subsequently obtained from the estimated bolometer noise voltage with respect to the measured bolometer responsivity. The NEP of better 2 × 10−18 W/Hz1/2 was obtained for modulation frequencies greater than 100 Hz. The background power and the bolometer time constant were also estimated from the experimental results. The photon-noise-limited operation of CEB will dominate for a signal power of 10 fW and higher at frequency 80 GHz and higher.

Applied Sciences•May 18, 2021•1 citation
Two series/parallel arrays of ten cold-electron bolometers with superconductor-insulator-normal tunnel junctions were integrated in orthogonal ports of a cross-slot antenna. To increase the dynamic range of the receiver, all single bolometers in an array are connected in parallel for the microwave signal by capacitive coupling. To increase the output response, bolometers are connected in series for dc bias. With the measured voltage-to-temperature response of 8.8 μV/mK, absorber volume of 0.08 μm3, and output noise of about 10 nV/Hz1/2, we estimated the dark electrical noise equivalent power (NEP) as NEP = 6 * 10-18W/Hz1/2. The optical response down to NEP = 2 * 10-17W/Hz1/2was measured using a hot/cold load as a radiation source and a sample temperature down to 100 mK. The fluctuation sensitivity to the radiation source temperature is 1.3 * 10-4K/Hz1/2. A dynamic range over 43 dB was measured using a backward-wave oscillator, a variable polarization grid attenuator, and cold filters/attenuators.
Cold electron bolometers integrated with twin-slot antennas have been designed and fabricated. Optical response was measured in 0.06-0.6 K temperature range using black body radiation source at temperature 2-15 K. The responsivity of 0.3109 V/W was measured at 2.7 K radiation temperature. The estimated ultimate dark responsivity at 100 mK can approach Sv=1010 V/W and reduces down to 1.1108 V/W at 300 mK for the sample with absorber volume of 510-20 m3. At high power load levels and low temperatures the changes of tunneling current, dynamic resistance and voltage response have been explained by non-thermal energy distribution of excited electrons. Distribution of excited electrons in such system is of none-Fermi type, electrons with energies of the order of 1 K tunnel from normal metal absorber to superconductor instead of relaxing down to thermal energy kTe. This effect can reduce quantum efficiency of bolometer from hf/kTph in ideal case down to single electron per signal quantum in the high power case.
A novel concept of the parallel/series array of Cold-Electron Bolometers (CEB) with Superconductor-Insulator-Normal (SIN) Tunnel Junctions has been proposed for matching with JFET readout. The current-biased CEBs are connected in series for DC and in parallel for HF signal. A signal is concentrated to the absorber through the capacitance of tunnel junctions and additional capacitance for coupling of superconducting islands. Due to dividing power between CEBs in the array and increasing responsivity, the noise matching could be effectively optimized and the photon Noise Equivalent Power could be easily achieved at 300 mK with a room temperature JFET readout.
We present experimental results on the testing of cold-electron bolometer (CEB) detectors comprised of a thin Ti film absorber and two SIN junctions integrated with a planar antenna. The CEB performance was tested in a He-3 sorption cryostat HELIOX-AC-V at bath temperatures of 280-305 mK. The optical response was measured using the hot/cold load method by flipping a Cu reflector opposite a blackbody surface inside a 3 K shield and using a thermal source with variable temperature. In the first experiment, the detector chip was mounted in an optical sample-holder whose aperture was switched towards or away from a blackbody source changing the incident radiation temperature from 3 K to 270 mK. As a result, we measured the optical response to a 3 K/270 mK radiation temperature change. The measured voltage response value for the detector integrated in a double-dipole antenna was Delta V-out = 120 mu V. This corresponds to a noise equivalent power of NEP = V-n/(dV/dP) = 3.5 x 10(-17) W Hz(-1/2), where dV/dP is the voltage to power response obtained from the incoming power estimation based on the Planck formula.
In this paper, we present the measurements of optical response dependence on power load of a Cold Electron Bolometer integrated in a twin slot antenna. These measurements are also compared to the models of the bolometer limit and the photon counter limit. The responsivity of 0.22*109V/W was measured at 0.22 pW radiation power from a black body at 3.5 K. According to our estimations, for optimized device the voltage responsivity at 100 mK electron temperature can approach S v = 1010V/W for power load below 0.1 pW and decreases down to 107V/W at 300 mK for 5 pW signal power in a sample with absorber volume of 5*10-20m3. In the case of low bath temperatures and high applied RF power the changes of tunneling current, dynamic resistance and voltage response are explained by non-thermal energy distribution of excited electrons. Distribution of excited electrons in such system at lower temperatures can be of non-Fermi type, hot electrons with energies of the order of 1 K tunnel from normal metal absorber to superconductor instead of relaxing down to thermal energy kTein absorber before tunneling. This effect can reduce quantum efficiency of the bolometer at 350 GHz from η = hf/kTph> 100 in ideal case down to single electron per absorbed photon ( η = 1) in the high power case. Methods of preserving high quantum efficiency are discussed.
For sensitive wideband spectroscopy at THz frequencies with performance better than for Fourier Transform Spectrometer, one needs a wide-range electrically tunable, narrow linewidth THz source, and a sensitive broadband detector. To obtain a low noise level of sensor we use a superconducting normal metal cold electron bolometer (CEB). A voltage response of the bolometer is 4.108 V/W and an amplifier-limited technical noise equivalent power of the bolometer is 1.25.10-17 W/Hz1/2. The wide band electrically tuned terahertz band cryogenic oscillator is a Josephson junction. Contrary to conventional Josephson junctions based on niobium, and naturally limited in frequency by energy gap of about 700 GHz, the high critical temperature YBaCuO junctions can extend this limit by an order of magnitude. At 4 K such oscillators can radiate at frequencies exceeding 2 THz. Signals received by bolometers integrated with double-dipole and log-periodic antennas and irradiated by the Josephson oscillator show in our experiments the high frequency response corresponding to an oscillation frequency of up to 1.75 THz. Such cryogenic terahertz network analyzer is suitable for low-signal spectral evaluation of cryogenic detectors, quasioptical sub-mm cryogenic filters, planar antennas with planar microwave filters, integrated structures comprising such elements, and arrays of cryogenic receivers.
We have developed a single-pixel capacitively coupled Cold-Electron Bolometer (CEB) and characterized it in the current-biased regime. The most attractive feature of the CEB is effective electron self-cooling of the absorber, which leads to a lower bolometer noise and higher dynamic range. The bolometer responsivity was measured by determining the voltage response to an applied power through the absorber from a heating current, modulated at frequencies from 35 Hz to 2 kHz. The optimum responsivity of 1.5 × 1010 V/W was measured at a modulation frequency of 35 Hz. The noise equivalent power (NEP) was subsequently obtained from the estimated bolometer noise voltage with respect to the measured bolometer responsivity. The NEP of better 2 × 10−18 W/Hz1/2 was obtained for modulation frequencies greater than 100 Hz. The background power and the bolometer time constant were also estimated from the experimental results. The photon-noise-limited operation of CEB will dominate for a signal power of 10 fW and higher at frequency 80 GHz and higher.