Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review Letters

Contractive States and the Standard Quantum Limit for Monitoring Free-Mass Positions

Horace P. Yuen

Published Aug 29, 1983• 181 citations
Publisher

Abstract

The familiar minimum-uncertainty wave packets for masses are generalized in analogy with the two-photon coherent states of the radiation field. The free evolution of a subclass of these states, the contractive states, leads to a narrowing of the position uncertainty in contrast with the usual minimum-uncertainty wave packets. As a consequence the standard quantum limit for monitoring the positions of a free mass can be breached. Further implications on quantum nondemolition measurements are discussed.

DOI
10.1103/physrevlett.51.719

Related papers

Generic Contractive States and Quantum Monitoring of Free Masses and Oscillators

Priyanshi Bhasin, Ujan Chakraborty, Shasanka Mohan Roy

Monitoring photon quadratures and free masses are useful tools to detect small disturbances such as gravitational waves.Here we report a large class of states for photon quadratures and free masses potentially useful for this purpose: (1)'generic coherent states' (GCS) of photons, whose width is independent of time and uncertainty product $σ(x) σ(p) $ is arbitrarily large (a generalization of the minimum uncertainty Schrödinger coherent states and (2) `squeezed generic contractive states' (SGCS) for photons and free masses (a generalization of the Yuen states \cite{Yuen}) whose width decreases with time ,uncertainty product is arbitrarily large, and the covariance squared $ ^2 $ has an arbitrary value within the allowed range $(0,4 σ^2 (x) σ^2 (p) -1\>)$. Dedicated to the 125th birth anniversary of S. N. Bose.

arXiv:1903.11845•Mar 28, 2019•0 citations

Rigorous quantum limits on monitoring free masses and harmonic oscillators

Shasanka Mohan Roy

There are heuristic arguments proposing that the accuracy of monitoring position of a free mass $m$ is limited by the standard quantum limit (SQL): ${\ensuremath{\sigma}}^{2}(X(t))\ensuremath{\ge}{\ensuremath{\sigma}}^{2}(X(0))+({t}^{2}/{m}^{2}){\ensuremath{\sigma}}^{2}(P(0))\ensuremath{\ge}\ensuremath{\hbar}t/m$, where ${\ensuremath{\sigma}}^{2}(X(t))$ and ${\ensuremath{\sigma}}^{2}(P(t))$ denote variances of the Heisenberg representation position and momentum operators. Yuen [Phys. Rev. Lett. 51, 719 (1983)] discovered that there are contractive states for which this result is incorrect. Here I prove universally valid rigorous quantum limits (RQL), viz. rigorous upper and lower bounds on ${\ensuremath{\sigma}}^{2}(X(t))$ in terms of ${\ensuremath{\sigma}}^{2}(X(0))$ and ${\ensuremath{\sigma}}^{2}(P(0))$, given by Eq. (12) for a free mass and by Eq. (36) for an oscillator. I also obtain the maximally contractive and maximally expanding states which saturate the RQL, and use the contractive states to set up an Ozawa-type measurement theory with accuracies respecting the RQL but beating the standard quantum limit. The contractive states for oscillators improve on the Schr\"odinger coherent states of constant variance and may be useful for gravitational wave detection and optical communication.

arXiv:1711.10261•Physical Review A•Mar 13, 2018•1 citation

Quantum measurements of position, detection of weak classical forces, and interferometric noise

Wei-Tou Ni

We discuss quantum measurements of position and repeated-measurement schemes for monitoring free-mass position to an arbitrary accuracy. Using these schemes, weak classical forces can be monitored to an arbitrary accuracy. To illustrate various measurement uncertainties and intrinsic uncertainties, we consider the case of a Michelson interferometer. In the low-intensity limit, two measurement uncertainties, photon counting error and radiation pressure error, are independent of the intrinsic uncertainty. The uses of squeezed states and number eigenstates are discussed.

IEEE Transactions on Instrumentation and Measurement•Jun 1, 1987•0 citations

Measurement breaking the standard quantum limit for free-mass position

Masanao Ozawa

An explicit interaction-Hamiltonian realization of a measurement of the free-mass position with the following properties is given: (1) The probability distribution of the readouts is exactly the same as the free-mass position distribution just before the measurement. (2) The measurement leaves the free mass in a contractive state just after the measurement. It is shown that this measurement breaks the standard quantum limit for the free-mass position in the sense sharpened by the recent controversy.

Physical Review Letters•Feb 1, 1988•105 citations

Proof of the standard quantum limit for monitoring free-mass position

Seiji Kosugi

The measurement result of the moved distance for a free mass $m$ during the time $\ensuremath{\tau}$ between two position measurements cannot be predicted with uncertainty smaller than $\sqrt{\ensuremath{\hbar}\ensuremath{\tau}/m}$. This is formulated as a standard quantum limit and it has been proven to always hold for the following position measurement: a probe is set in a prescribed position before the measurement. Just after the interaction of the mass with the probe, the probe position is measured, and using this value, the measurement results of the premeasurement and postmeasurement positions are estimated.

arXiv:1005.5328•Physical Review A•Aug 30, 2010•0 citations

Quantum Nondemolition Measurement of Photon Number and Number-Phase Minimum Uncertainty State

Y. Yamamoto, N. Imoto, S. Machida

Two strategies for beating the standard quantum limit in preparation and measurement of optical quantum states are discussed. One is the quantum nondemolition (QND) measurement of the photon number using the optical Kerr effect. The other is the generation of number-phase minimum uncertainty states using either controlled reduction of the wave function by QND measurement and feedback or feedforward, or phase sensitive deamplification in a highly saturated laser oscillator with suppressed-pump-fluctuation.

Advanced series in applied physics•Jan 1, 1997•1 citation
The familiar minimum-uncertainty wave packets for masses are generalized in analogy with the two-photon coherent states of the radiation field. The free evolution of a subclass of these states, the contractive states, leads to a narrowing of the position uncertainty in contrast with the usual minimum-uncertainty wave packets. As a consequence the standard quantum limit for monitoring the positions of a free mass can be breached. Further implications on quantum nondemolition measurements are discussed.
Monitoring photon quadratures and free masses are useful tools to detect small disturbances such as gravitational waves.Here we report a large class of states for photon quadratures and free masses potentially useful for this purpose: (1)'generic coherent states' (GCS) of photons, whose width is independent of time and uncertainty product $σ(x) σ(p) $ is arbitrarily large (a generalization of the minimum uncertainty Schrödinger coherent states and (2) `squeezed generic contractive states' (SGCS) for photons and free masses (a generalization of the Yuen states \cite{Yuen}) whose width decreases with time ,uncertainty product is arbitrarily large, and the covariance squared $ ^2 $ has an arbitrary value within the allowed range (0,4σ2(x)σ2(p)−1 )(0,4 σ^2 (x) σ^2 (p) -1\>)(0,4σ2(x)σ2(p)−1). Dedicated to the 125th birth anniversary of S. N. Bose.
There are heuristic arguments proposing that the accuracy of monitoring position of a free mass mmm is limited by the standard quantum limit (SQL): ${\ensuremath{\sigma}}^{2}(X(t))\ensuremath{\ge}{\ensuremath{\sigma}}^{2}(X(0))+({t}^{2}/{m}^{2}){\ensuremath{\sigma}}^{2}(P(0))\ensuremath{\ge}\ensuremath{\hbar}t/m$, where ${\ensuremath{\sigma}}^{2}(X(t))$ and ${\ensuremath{\sigma}}^{2}(P(t))$ denote variances of the Heisenberg representation position and momentum operators. Yuen [Phys. Rev. Lett. 51, 719 (1983)] discovered that there are contractive states for which this result is incorrect. Here I prove universally valid rigorous quantum limits (RQL), viz. rigorous upper and lower bounds on ${\ensuremath{\sigma}}^{2}(X(t))$ in terms of ${\ensuremath{\sigma}}^{2}(X(0))$ and ${\ensuremath{\sigma}}^{2}(P(0))$, given by Eq. (12) for a free mass and by Eq. (36) for an oscillator. I also obtain the maximally contractive and maximally expanding states which saturate the RQL, and use the contractive states to set up an Ozawa-type measurement theory with accuracies respecting the RQL but beating the standard quantum limit. The contractive states for oscillators improve on the Schr\"odinger coherent states of constant variance and may be useful for gravitational wave detection and optical communication.
We discuss quantum measurements of position and repeated-measurement schemes for monitoring free-mass position to an arbitrary accuracy. Using these schemes, weak classical forces can be monitored to an arbitrary accuracy. To illustrate various measurement uncertainties and intrinsic uncertainties, we consider the case of a Michelson interferometer. In the low-intensity limit, two measurement uncertainties, photon counting error and radiation pressure error, are independent of the intrinsic uncertainty. The uses of squeezed states and number eigenstates are discussed.
An explicit interaction-Hamiltonian realization of a measurement of the free-mass position with the following properties is given: (1) The probability distribution of the readouts is exactly the same as the free-mass position distribution just before the measurement. (2) The measurement leaves the free mass in a contractive state just after the measurement. It is shown that this measurement breaks the standard quantum limit for the free-mass position in the sense sharpened by the recent controversy.
The measurement result of the moved distance for a free mass mmm during the time $\ensuremath{\tau}$ between two position measurements cannot be predicted with uncertainty smaller than $\sqrt{\ensuremath{\hbar}\ensuremath{\tau}/m}$. This is formulated as a standard quantum limit and it has been proven to always hold for the following position measurement: a probe is set in a prescribed position before the measurement. Just after the interaction of the mass with the probe, the probe position is measured, and using this value, the measurement results of the premeasurement and postmeasurement positions are estimated.
Two strategies for beating the standard quantum limit in preparation and measurement of optical quantum states are discussed. One is the quantum nondemolition (QND) measurement of the photon number using the optical Kerr effect. The other is the generation of number-phase minimum uncertainty states using either controlled reduction of the wave function by QND measurement and feedback or feedforward, or phase sensitive deamplification in a highly saturated laser oscillator with suppressed-pump-fluctuation.