Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Two-photon optical transients by intensity switching

Maryna D'Souza, Arvind Kumar

Published Sep 1, 1980• 4 citations
Publisher

Abstract

A new method of observing two-photon optical transients is proposed, namely, by intensity switching of incident cw laser beams. This method, which is an alternative to the standard dc Stark or frequency-switching techniques, employs the second-order optical (ac) Stark effect to throw the two-photon active levels in or out of resonance by appropriately switching the intensities of the two laser beams. Theoretical treatment for the three basic transients optical nutation, free induction decay, and two-pulse echo in thin samples using intensity switching, is given for both the cases: co- and counter-propagating beams. The feasibility of the method for the $5{S}_{\frac{1}{2}}\ensuremath{-}3{S}_{\frac{1}{2}}$ transition in Na vapor is demonstrated. An important feature is the apearance of an intensity-dependent beat frequency in the optical FID signal.

DOI
10.1103/physreva.22.1185

Related papers

Optical coherent transients by laser frequency switching

Azriel Z. Genack, Richard G. Brewer

A simple method for observing coherent optical-transient phenomena is described. Effects such as photon echoes and free induction decay (FID) should allow studies of the dynamic properties of atoms, molecules, and solids on a time scale ranging from milliseconds to \ensuremath{\sim} 50 ps. The frequency of a cw dye laser is switched with an intracavity electro-optic modulator, producing in an external sample coherent transients which are detected in the forward beam. Measurements of long dephasing times are possible, as in FID, because the laser can oscillate indefinitely at the new frequency following a step-function switching pulse. Measurements of short decay times are also practical because the switching time is not restricted by the laser gain or cavity ringing time. In addition, the dye's dephasing time of a few picoseconds or less is too rapid to interfere with these observations. Since the pulse sequence can be preselected, the entire class of coherent optical transients is accessible. The method thus incorporates all of the advantages inherent in Stark switching, including heterodyne detection and high sensitivity, without being restricted to Stark-tunable systems. Laser frequency switching is discussed also in terms of a theoretical model which exposes the time-dependent properties of a phase-modulated cavity mode. Dephasing studies have been carried out thus far in atomic and molecular gases and low-temperature solids containing inorganic impurity ions or large organic molecules. The utility of the FID effect is emphasized where precise dephasing times are obtained from time-frequency Fourier transformation of FID signals using a digital computer. The first quantitative and detailed test of FID theory is provided by these experimental techniques.

Physical Review A•Apr 1, 1978•63 citations

Coherent two-photon processes: Transient and steady-state cases

Richard G. Brewer, Erwin Louis Hahn

A class of molecular two-photon processes, occurring under transient or steady-state conditions, is analyzed exactly for certain cases using a density-matrix formalism. Our results are relevant to the recently observed phenomena of transient coherent Raman beats and steady-state two-photon absorption of oppositely directed laser beams. Lowest-order perturbation theories have shown that these processes are insensitive to the Doppler effect, and consequently the linewidth is unaffected by Doppler broadening and by elastic collisions that change molecular velocity. The solutions presented here are of the same form for the Raman and two-photon problems and reveal significant power-dependent frequency shifts and line broadening that correct the ideal Doppler-free solutions. For the transient case, we assume a molecular three-level quantum structure that can be switched in or out of optical resonance with cw laser radiation by means of a pulsed dc Stark field, but the solutions also apply when resonant optical pulses are introduced. During the resonant condition when the Stark pulse is on, the three levels are prepared in coherent superposition, and during the nonresonant condition following the Stark pulse, the laser field(s) stimulates the coherently prepared sample in a transient two-photon process. One of these processes, the Ramanbeat effect, has been observed in forward scattering, but the second one, transient two-photon emission, should be observable in backward scattering. Bloch-like equations are derived for this three-level problem that facilitate an exact pulse solution for state preparation. Following the pulse, transient decay is well-approximated by a perturbation calculation. For the steady-state case, an exact solution is also obtained and is of interest for continuous-wave spectroscopy or for transient experiments requiring an initial preparation of quantum states, prior to Stark switching. These solutions exhibit a power-dependent line broadening and a frequency shift of magnitude $\ensuremath{\sim}\frac{\ensuremath{\Delta}({\ensuremath{\alpha}}^{2}\ensuremath{-}{\ensuremath{\beta}}^{2})}{({\ensuremath{\Delta}}^{2}+\frac{1}{{T}_{2}^{2}})}$, in agreement with our earlier estimate, where $\ensuremath{\alpha}$ and $\ensuremath{\beta}$ are the Rabi flopping frequencies for the two intermediate transitions and $\ensuremath{\Delta}$ is the off-resonance tuning behavior for one of them.

Physical Review A•May 1, 1975•342 citations

Coherent transients in molecular gases: comparison of two techniques

Н. Н. Рубцова

Each of three basic coherent transient phenomena (optical nutation, free polarization decay photon echo) can be generated by sufficiently abrupt modulation of the interaction between the matter and radiation. This can be performed by rapid commutation of either radiation parameters, or the parameters of the matter. I present here comparative analysis of these two approaches (the first one, using electro-optical switching of the resonant laser power to create the pulses for the gas excitation and the second one, based on the Stark switching of vibro-rotational levels in a gas, excited by CW laser radiation), used in our experiments in molecular gases, from the point of view of both their capability to generate various coherent transients and their sensitivity to the intensity of laser radiation.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Nov 15, 2001•0 citations

Observation of Two-Photon Optical Free-Induction Decay in Atomic Sodium Vapor

P. F. Liao, John E. Bjorkholm, J. P. Gordon

We have used the Stark-switching technique to observe two-photon optical free-induction decay in the visible using sodium vapor. Transients were observed with use of both a resonant and a nonresonant intermediate state for the two-photon transition.

Physical Review Letters•Jul 4, 1977•40 citations

Coherent Transients by Laser-Acoustical Diffraction Spectroscopy

A. H. Zewail

Recently we have reported[1] on the measurements of electronic dephasing (T_2) and radiationless decay (T_1) in molecules using emission spectroscopy as a probe for the detection of the photon echo. This right-angle photon echo utilizes a single mode of a narrow-band (~MHz) cw dye laser and an intracavity electro-optical (EO) element that modulates the frequency of the laser.[2] Applying voltage pulses into the EO crystal switches the laser frequency from ω_0 (the peak frequency of the transition resonance) into another frequency ω. This switching procedure introduced by Brewer et al. for the observation of transients in the forward direction of the laser allows one to observe coherent transients in gases,[1,2] solids[3-5] and molecular beams.[6] Typically, the dispersion of the nonlinear EO crystal (e.g., AD*P) gives a 60 MHz frequency shift within the inhomogeneous resonance of the optical transition (width ~GHz or larger). Therefore, to switch the laser frequency further, one must use high-voltage signals that are usually hard to obtain especially for multiple-pulse experiments. Secondly, there is a limit on the frequency shift which is conditioned by the mode spacing of the cavity. Thirdly, because the laser is switched into a new group of molecules some complications may arise in interpreting the transient spectra especially in large molecules. This is because in large molecules the density of excited states is high and thus the buildup of transients of w molecules (which could be complex) will be superimposed on the decay of ω_0 molecules. Finally, off-resonance effects (e.g., beats) between the molecules at frequency ω and ω_0 cannot be avoided.

Journal of the Optical Society of America A•May 1, 1978•1 citation

Optical Free Induction Decay

Richard G. Brewer, R. L. Shoemaker

A simple application of the Stark-pulse technique, developed by Brewer and Shoemaker, demonstrates optical free induction decay-the optical analog of free induction decay in NMR. A molecular sample which is coherently prepared by a cw laser beam exhibits such a decay when it is suddenly switched out of resonance by a Stark field. Observations are presented for a nondegenerate Doppler-broadened infrared transition of N${\mathrm{H}}_{2}$D, where the sample is optically thin, and the decay behavior can be compared quantitatively with a solution of the Bloch equations. When the molecular sample is prepared under steady-state conditions, the solutions are analytic; for pulse excitation, a numerical solution is required. The treatment invokes a hard-collision relaxation model. Such characteristics as the abrupt termination of the decay and the related edge echo, which result from Doppler dephasing, can be examined for Stark pulses of finite extent.

Physical Review A•Dec 1, 1972•316 citations
A new method of observing two-photon optical transients is proposed, namely, by intensity switching of incident cw laser beams. This method, which is an alternative to the standard dc Stark or frequency-switching techniques, employs the second-order optical (ac) Stark effect to throw the two-photon active levels in or out of resonance by appropriately switching the intensities of the two laser beams. Theoretical treatment for the three basic transients optical nutation, free induction decay, and two-pulse echo in thin samples using intensity switching, is given for both the cases: co- and counter-propagating beams. The feasibility of the method for the 5S12\ensuremath−3S125{S}_{\frac{1}{2}}\ensuremath{-}3{S}_{\frac{1}{2}}5S21​​\ensuremath−3S21​​ transition in Na vapor is demonstrated. An important feature is the apearance of an intensity-dependent beat frequency in the optical FID signal.
A simple method for observing coherent optical-transient phenomena is described. Effects such as photon echoes and free induction decay (FID) should allow studies of the dynamic properties of atoms, molecules, and solids on a time scale ranging from milliseconds to \ensuremath{\sim} 50 ps. The frequency of a cw dye laser is switched with an intracavity electro-optic modulator, producing in an external sample coherent transients which are detected in the forward beam. Measurements of long dephasing times are possible, as in FID, because the laser can oscillate indefinitely at the new frequency following a step-function switching pulse. Measurements of short decay times are also practical because the switching time is not restricted by the laser gain or cavity ringing time. In addition, the dye's dephasing time of a few picoseconds or less is too rapid to interfere with these observations. Since the pulse sequence can be preselected, the entire class of coherent optical transients is accessible. The method thus incorporates all of the advantages inherent in Stark switching, including heterodyne detection and high sensitivity, without being restricted to Stark-tunable systems. Laser frequency switching is discussed also in terms of a theoretical model which exposes the time-dependent properties of a phase-modulated cavity mode. Dephasing studies have been carried out thus far in atomic and molecular gases and low-temperature solids containing inorganic impurity ions or large organic molecules. The utility of the FID effect is emphasized where precise dephasing times are obtained from time-frequency Fourier transformation of FID signals using a digital computer. The first quantitative and detailed test of FID theory is provided by these experimental techniques.
A class of molecular two-photon processes, occurring under transient or steady-state conditions, is analyzed exactly for certain cases using a density-matrix formalism. Our results are relevant to the recently observed phenomena of transient coherent Raman beats and steady-state two-photon absorption of oppositely directed laser beams. Lowest-order perturbation theories have shown that these processes are insensitive to the Doppler effect, and consequently the linewidth is unaffected by Doppler broadening and by elastic collisions that change molecular velocity. The solutions presented here are of the same form for the Raman and two-photon problems and reveal significant power-dependent frequency shifts and line broadening that correct the ideal Doppler-free solutions. For the transient case, we assume a molecular three-level quantum structure that can be switched in or out of optical resonance with cw laser radiation by means of a pulsed dc Stark field, but the solutions also apply when resonant optical pulses are introduced. During the resonant condition when the Stark pulse is on, the three levels are prepared in coherent superposition, and during the nonresonant condition following the Stark pulse, the laser field(s) stimulates the coherently prepared sample in a transient two-photon process. One of these processes, the Ramanbeat effect, has been observed in forward scattering, but the second one, transient two-photon emission, should be observable in backward scattering. Bloch-like equations are derived for this three-level problem that facilitate an exact pulse solution for state preparation. Following the pulse, transient decay is well-approximated by a perturbation calculation. For the steady-state case, an exact solution is also obtained and is of interest for continuous-wave spectroscopy or for transient experiments requiring an initial preparation of quantum states, prior to Stark switching. These solutions exhibit a power-dependent line broadening and a frequency shift of magnitude $\ensuremath{\sim}\frac{\ensuremath{\Delta}({\ensuremath{\alpha}}^{2}\ensuremath{-}{\ensuremath{\beta}}^{2})}{({\ensuremath{\Delta}}^{2}+\frac{1}{{T}_{2}^{2}})}$, in agreement with our earlier estimate, where $\ensuremath{\alpha}$ and $\ensuremath{\beta}$ are the Rabi flopping frequencies for the two intermediate transitions and $\ensuremath{\Delta}$ is the off-resonance tuning behavior for one of them.
Each of three basic coherent transient phenomena (optical nutation, free polarization decay photon echo) can be generated by sufficiently abrupt modulation of the interaction between the matter and radiation. This can be performed by rapid commutation of either radiation parameters, or the parameters of the matter. I present here comparative analysis of these two approaches (the first one, using electro-optical switching of the resonant laser power to create the pulses for the gas excitation and the second one, based on the Stark switching of vibro-rotational levels in a gas, excited by CW laser radiation), used in our experiments in molecular gases, from the point of view of both their capability to generate various coherent transients and their sensitivity to the intensity of laser radiation.
Recently we have reported[1] on the measurements of electronic dephasing (T_2) and radiationless decay (T_1) in molecules using emission spectroscopy as a probe for the detection of the photon echo. This right-angle photon echo utilizes a single mode of a narrow-band (~MHz) cw dye laser and an intracavity electro-optical (EO) element that modulates the frequency of the laser.[2] Applying voltage pulses into the EO crystal switches the laser frequency from ω_0 (the peak frequency of the transition resonance) into another frequency ω. This switching procedure introduced by Brewer et al. for the observation of transients in the forward direction of the laser allows one to observe coherent transients in gases,[1,2] solids[3-5] and molecular beams.[6] Typically, the dispersion of the nonlinear EO crystal (e.g., AD*P) gives a 60 MHz frequency shift within the inhomogeneous resonance of the optical transition (width ~GHz or larger). Therefore, to switch the laser frequency further, one must use high-voltage signals that are usually hard to obtain especially for multiple-pulse experiments. Secondly, there is a limit on the frequency shift which is conditioned by the mode spacing of the cavity. Thirdly, because the laser is switched into a new group of molecules some complications may arise in interpreting the transient spectra especially in large molecules. This is because in large molecules the density of excited states is high and thus the buildup of transients of w molecules (which could be complex) will be superimposed on the decay of ω_0 molecules. Finally, off-resonance effects (e.g., beats) between the molecules at frequency ω and ω_0 cannot be avoided.
A simple application of the Stark-pulse technique, developed by Brewer and Shoemaker, demonstrates optical free induction decay-the optical analog of free induction decay in NMR. A molecular sample which is coherently prepared by a cw laser beam exhibits such a decay when it is suddenly switched out of resonance by a Stark field. Observations are presented for a nondegenerate Doppler-broadened infrared transition of NH2{\mathrm{H}}_{2}H2​D, where the sample is optically thin, and the decay behavior can be compared quantitatively with a solution of the Bloch equations. When the molecular sample is prepared under steady-state conditions, the solutions are analytic; for pulse excitation, a numerical solution is required. The treatment invokes a hard-collision relaxation model. Such characteristics as the abrupt termination of the decay and the related edge echo, which result from Doppler dephasing, can be examined for Stark pulses of finite extent.