Physical Review B

Publisher's Note: Quantum capacitance detector: A pair-breaking radiation detector based on the single Cooper-pair box [Phys. Rev. B79, 144511 (2009)]

Matthew D. Shaw, Juan Bueno, Peter K. Day, C. Matt Bradford, P. M. Echternach

Published May 13, 2009• 1 citation
Publisher
DOI
10.1103/physrevb.79.179902

Related papers

Measuring the Quantum Capacitance of a Differential Single Cooper-Pair Box

Matthew D. Shaw, Justin F. Schneiderman, Per Delsing +2 more

Bulletin of the American Physical Society•Mar 14, 2006•0 citations

Single photon detection of 1.5 THz radiation with the quantum capacitance detector

P. M. Echternach, Brian J. Pepper, Theodore Reck +1 more

Nature Astronomy•Nov 2, 2017•111 citations

Correlation-induced suppression of decoherence in capacitively coupled Cooper-pair boxes

Xuedong Hu, J. Q. You, Franco Nori

Bulletin of the American Physical Society•Mar 22, 2005•0 citations

Proof of concept of the quantum capacitance detector

Juan Bueno, Matthew D. Shaw, Peter K. Day +1 more

We fabricated and tested a proof-of-concept quantum capacitance detector, a superconducting radiation detector described in a recent publication [Shaw et al., Phys. Rev. B 79, 144511 (2009)]. In this concept, quasiparticle tunneling in a single Cooper-pair box is used to measure the density of quasiparticles in a superconducting absorber. We measured and characterized the response of the device to electrical quasiparticle injection obtaining its sensitivity. Moreover, we have converted the sensitivity to electrical noise-equivalent power, which is in the 10−18 W/Hz1/2 range at loading powers between 10−15–10−16 W.

Applied Physics Letters•Mar 8, 2010•19 citations

Quantum capacitance detector: A pair-breaking radiation detector based on the single Cooper-pair box

Matthew D. Shaw, Juan Bueno, Peter K. Day +2 more

We present a proposed design for a pair-breaking photodetector for far-infrared and submillimeter radiation. Antenna-coupled radiation generates quasiparticles in a superconducting absorber, the density of which are measured using a single Cooper-pair box. Readout is performed using an electromagnetic oscillator or a microwave resonator, which is well suited for frequency multiplexing in large arrays. Theoretical limits to detector sensitivity are discussed and modeled, with predicted sensitivities on the order of ${10}^{\ensuremath{-}21}\text{ }\text{W}/\sqrt{\text{Hz}}$. We anticipate that this detector can be used to address key scientific goals in far-infrared and submillimeter astronomy.

arXiv:0902.4194•Physical Review B•Apr 14, 2009•38 citations

Progress in the development of a single Cooper-pair box qubit

P. M. Echternach, Justin F. Schneiderman, Matthew D. Shaw +1 more

Quantum Information Processing•Feb 7, 2009•1 citation
We fabricated and tested a proof-of-concept quantum capacitance detector, a superconducting radiation detector described in a recent publication [Shaw et al., Phys. Rev. B 79, 144511 (2009)]. In this concept, quasiparticle tunneling in a single Cooper-pair box is used to measure the density of quasiparticles in a superconducting absorber. We measured and characterized the response of the device to electrical quasiparticle injection obtaining its sensitivity. Moreover, we have converted the sensitivity to electrical noise-equivalent power, which is in the 10−18 W/Hz1/2 range at loading powers between 10−15–10−16 W.
We present a proposed design for a pair-breaking photodetector for far-infrared and submillimeter radiation. Antenna-coupled radiation generates quasiparticles in a superconducting absorber, the density of which are measured using a single Cooper-pair box. Readout is performed using an electromagnetic oscillator or a microwave resonator, which is well suited for frequency multiplexing in large arrays. Theoretical limits to detector sensitivity are discussed and modeled, with predicted sensitivities on the order of ${10}^{\ensuremath{-}21}\text{ }\text{W}/\sqrt{\text{Hz}}$. We anticipate that this detector can be used to address key scientific goals in far-infrared and submillimeter astronomy.