Laser Physics

Optical frequency standard based on the coherent population trapping resonance

E. V. Baklanov, Sergei N Bagayev, А. К. Дмитриев, А. В. Тайченачев, Valeriy I. Yudin

Published May 29, 2014• 6 citations
Publisher

Abstract

We propose an optical frequency standard which uses as a reference the coherent population trapping resonance. This frequency standard is based on a self-mode-locked laser with the frequency of pulse repetition directly locked to the hyperfine splitting of 133 Cs. An important feature of the proposed standard consists in the absence of a source of microwave radiation.

DOI
10.1088/1054-660x/24/7/074007

Related papers

Optical frequency standard based on coherent population trapping resonance

E. V. Baklanov, А. К. Дмитриев

We propose a new optical frequency standard, based on a coherent population trapping resonance. Such standard is a self-mode locking laser, pulse repetition frequency of which is directly locked to microwave clock-transition—the transition between the hyperfine ground state components of alkali atom. The unique properties of this standard result in reduction of the light shift which is the main reason limiting frequency stability of this standard.

Laser Physics•Jan 1, 2010•11 citations

Passive atomic frequency standard based on coherent population trapping in ^87Rb using injection-locked lasers

Han Seb Moon, Sang Eon Park, Young‐Ho Park +2 more

We present a microwave frequency standard based on coherent population trapping (CPT) in the 87Rb D1 line. The CPT spectrum is obtained using two Raman lasers with a 6.8 GHz frequency offset by injection locking of a master laser to a slave laser. We have constructed an atomic clock employing a 5 cm long Rb vapor cell confined with 6.67 kPa neon buffer gas at 70 °C. Using this system, we improve the CPT contrast through the elimination of undesired off-resonant fields created by the direct modulation method. We measured the frequency shift of the CPT signal as a function of the temperature of the Rb cell and estimated it to be approximately 1.3 ×10−9/K. The frequency of a 10 MHz crystal oscillator has been stabilized to the CPT spectrum between the two ground states in 87Rb. The relative frequency stability is approximately 2.3×10−12 for an average time of 68 s.

Journal of the Optical Society of America B•Nov 1, 2006•23 citations

Atomic clocks based on coherent population trapping: basic theoretical models and frequency stability

Jaques Vanier, A. Godone, Filippo Levi +1 more

The paper gives an overview of our present theoretical understanding of coherent population trapping in alkali metal atoms as used in the implementation of an atomic frequency standard. Two approaches are examined: The passive approach in which the microwave hyperfine resonance is detected directly on the transmitted radiation and the maser approach in which the same resonance is observed by means of stimulated emission in a microwave cavity. The theoretical analysis reviewed is supported by experimental results.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 8, 2004•10 citations

A new atomic frequency standard: the coherent population trapping Cs maser

A. Godone, Filippo Levi, Jaques Vanier

Recent studies have shown the feasibility of a Cs maser without population inversion based on the coherent population trapping phenomenon. Among the main advantages of this type of frequency standard are size, simplicity of implementation, virtual absence of first order light shift and the availability of a low noise microwave signal leading to the realization of a standard with an excellent short term frequency stability.

Conference on Precision Electromagnetic Measurements•Nov 27, 2002•1 citation

Coherent microwave emission without population inversion: a new atomic frequency standard

A. Godone, Filippo Levi, Jaques Vanier

The description of a new type of frequency standard based on coherent population trapping (CPT) in cesium is given. The phenomenon creates a magnetization oscillating at the hyperfine frequency. Microwave radiation emitted by such a magnetization is detected by means of a microwave cavity. The process takes place without population inversion. Results are given for continuous and pulsed operation. The possibility of using the CPT coherent microwave emission as the basis of a frequency standard is analyzed.

IEEE Transactions on Instrumentation and Measurement•Apr 1, 1999•19 citations

All-optical atomic clock based on coherent population trapping in ^85Rb

Mikko Merimaa, Thomas Lindvall, Ilkka Juhani Tittonen +1 more

An all-optical microwave frequency standard based on coherent population trapping (CPT) in 85Rb is developed. The CPT resonances are detected by an ordinary edge-emitting diode laser in a simple optical setup. A buffer-gas mixture is carefully optimized to yield a narrow linewidth and a reduced temperature dependence of the resonance frequency. With the developed system we are able to measure ultranarrow optically induced hyperfine CPT resonances at <20 Hz, which is in good agreement with the linewidth calculated from experimental parameters. The frequency of an RF-signal generator has been stabilized to the CPT resonance between the two mF=0 magnetic sublevels. The relative frequency stability (square root of Allan variance) follows a slope of 3.5×10-11 τ-1/2(1 s<τ<2000 s). The best stability of 6.4×10-13 is reached at an integration time of τ=2000 s. This stability is sufficient for many high-precision applications. Frequency-shift measurements were made to evaluate the frequency dependencies on the operation parameters.

Journal of the Optical Society of America B•Feb 1, 2003•132 citations
We propose an optical frequency standard which uses as a reference the coherent population trapping resonance. This frequency standard is based on a self-mode-locked laser with the frequency of pulse repetition directly locked to the hyperfine splitting of 133 Cs. An important feature of the proposed standard consists in the absence of a source of microwave radiation.
We present a microwave frequency standard based on coherent population trapping (CPT) in the 87Rb D1 line. The CPT spectrum is obtained using two Raman lasers with a 6.8 GHz frequency offset by injection locking of a master laser to a slave laser. We have constructed an atomic clock employing a 5 cm long Rb vapor cell confined with 6.67 kPa neon buffer gas at 70 °C. Using this system, we improve the CPT contrast through the elimination of undesired off-resonant fields created by the direct modulation method. We measured the frequency shift of the CPT signal as a function of the temperature of the Rb cell and estimated it to be approximately 1.3 ×10−9/K. The frequency of a 10 MHz crystal oscillator has been stabilized to the CPT spectrum between the two ground states in 87Rb. The relative frequency stability is approximately 2.3×10−12 for an average time of 68 s.
The paper gives an overview of our present theoretical understanding of coherent population trapping in alkali metal atoms as used in the implementation of an atomic frequency standard. Two approaches are examined: The passive approach in which the microwave hyperfine resonance is detected directly on the transmitted radiation and the maser approach in which the same resonance is observed by means of stimulated emission in a microwave cavity. The theoretical analysis reviewed is supported by experimental results.
The description of a new type of frequency standard based on coherent population trapping (CPT) in cesium is given. The phenomenon creates a magnetization oscillating at the hyperfine frequency. Microwave radiation emitted by such a magnetization is detected by means of a microwave cavity. The process takes place without population inversion. Results are given for continuous and pulsed operation. The possibility of using the CPT coherent microwave emission as the basis of a frequency standard is analyzed.
An all-optical microwave frequency standard based on coherent population trapping (CPT) in 85Rb is developed. The CPT resonances are detected by an ordinary edge-emitting diode laser in a simple optical setup. A buffer-gas mixture is carefully optimized to yield a narrow linewidth and a reduced temperature dependence of the resonance frequency. With the developed system we are able to measure ultranarrow optically induced hyperfine CPT resonances at <20 Hz, which is in good agreement with the linewidth calculated from experimental parameters. The frequency of an RF-signal generator has been stabilized to the CPT resonance between the two mF=0 magnetic sublevels. The relative frequency stability (square root of Allan variance) follows a slope of 3.5×10-11 τ-1/2(1 s<τ<2000 s). The best stability of 6.4×10-13 is reached at an integration time of τ=2000 s. This stability is sufficient for many high-precision applications. Frequency-shift measurements were made to evaluate the frequency dependencies on the operation parameters.