Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics

Sub shot noise measurement without a separate local oscillator

O. Glöckl, Ulrik L. Andersen, Stefan Lorenz, Natalia Korolkova, Gerd Leuchs

Published Jan 1, 2004• 0 citations
Publisher

Abstract

We present an interferometric setup to perform sub-shot-noise measurements of the phase quadrature for intense pulsed light without additional local oscillator. Non-separability of a pair of quadrature entangled beams is demonstrated experimentally with this setup.
DOI
10.1364/iqec.2004.itug7

Related papers

Sub-shot-noise phase quadrature measurement of intense light beams

O. Glöckl, Ulrik L. Andersen, Stefan Lorenz +3 more

We present a setup for performing sub-shot-noise measurements of the phase quadrature of intense pulsed light without the use of a separate local oscillator. A Mach-Zehnder interferometer with an unbalanced arm length is used to detect the fluctuations of the phase quadrature at a single sideband frequency. With this setup, the nonseparability of a pair of quadrature-entangled beams is demonstrated experimentally.

arXiv:quant-ph/0406087•Optics Letters•Aug 13, 2004•36 citations

Accessing the Phase Quadrature of Intense Non-Classical Light State

O. Glöckl, Ulrik L. Andersen, Gerd Leuchs

Phase sensitive measurements are required to characterize the quantum state of a light field in the regime of continuous variables. The standard approach to do this is to use homodyne detection. However, if the signal beam under investigation is very intense, this technique is not appropriate. We present a setup for performing sub-shot-noise measurements of the phase quadrature of intense pulsed light without the use of a separate local oscillator. A Mach Zehnder interferometer with an unbalanced arm length is used to detect the fluctuations of the phase quadrature at a single sideband frequency. Using that tool, short entangled light pulses generated in optical fibres could be applied efficiently in quantum information and quantum communication protocols. We show experimentally that the setup can be used to demonstrate the non–separability of a pair of quadrature-entangled beams.

IMPERIAL COLLEGE PRESS eBooks•Feb 1, 2007•0 citations

Sub shot noise phase measurement without a separate local oscillator

Glockl, Andersen, Korolkova +1 more

Conference on Lasers and Electro-Optics•Jan 1, 2004•0 citations

Quantum Fiber Solitons – Generation, Entanglement, and Detection

Gerd Leuchs, Natalia Korolkova, Oliver Glöck +5 more

This chapter contains sections titled: Introduction Quantum Correlations and Entanglement Multimode Quantum Correlations Generation of Bright Entangled Beams Detection of Entanglement of Bright Beams Sub-shot-noise Phase Quadrature Measurements on Intense Beams Direct Experimental Test of Non-Separability Entanglement Swapping Polarization Variables References

Quantum Information Processing•Feb 17, 2005•0 citations

Sub-Shot Noise Interferometry and Quantum Imaging

Richard E. Slusher, Arthur La Porta, Philippe Grangier +2 more

Optimizing the sensitivity for interferometric measurement of optical phase involves maximizing the intensity of the illuminating light source and minimizing any noise sources. Limits to the light source intensity may arise from the availability of a stable high-power laser or from damage to the system being measured. For example, we describe here a scanning confocal polarization microscope designed to image the dynamics of nerve networks. In this case the light intensity limit is set by several factors, including the scanning rate, the required response time and damage limits of the biological system. Assuming a stable experimental configuration for the interferometer and light source, the limiting noise source for visible light interferometry is shot-noise associated with the quantum state of the light inputs to the interferometer. Shot-noise can be thought of as arising from vacuum fluctuations entering the dark input port of the interferometer.(1) These vacuum field fluctuations combine with the light entering the other port to cause shot-noise in the detected photocurrent at the output ports of the interferometer. This shot-noise current normally limits the measured phase variance Δϕ to a value of 1/N where N is the average number of photons detected in a measurement interval. We describe an experiment which demonstrates that this shot-noise limit can be improved by injecting squeezed vacuum into the normally dark input port.(2) In this case the phase variance is reduced below the 1/N limit by the degree of squeezing. In contrast to early experiments,(2) we are now operating the interferometer in a dark fringe mode(3–5) in order to avoid setting a limit to the light level caused by detector saturation (near 1 mW).

Topical Meeting on Quantum-Limited Imaging and Image Processing•Jan 1, 1989•0 citations

Sub-shot-noise measurements using the beat note between quantum-correlated photon beams

J. J. Snyder, E. Giacobino, M. Ducloy +2 more

We propose a new method for optical measurements below the shot-noise limit. The method is based on detecting the beat note between the two quantum-correlated beams emitted by a nondegenerate optical parametric oscillator operating above threshold. Such a method can be used to enhance the sensitivity of light-scattering and polarization-rotation measurements.

Journal of the Optical Society of America B•Oct 1, 1990•28 citations
Phase sensitive measurements are required to characterize the quantum state of a light field in the regime of continuous variables. The standard approach to do this is to use homodyne detection. However, if the signal beam under investigation is very intense, this technique is not appropriate. We present a setup for performing sub-shot-noise measurements of the phase quadrature of intense pulsed light without the use of a separate local oscillator. A Mach Zehnder interferometer with an unbalanced arm length is used to detect the fluctuations of the phase quadrature at a single sideband frequency. Using that tool, short entangled light pulses generated in optical fibres could be applied efficiently in quantum information and quantum communication protocols. We show experimentally that the setup can be used to demonstrate the non–separability of a pair of quadrature-entangled beams.
Optimizing the sensitivity for interferometric measurement of optical phase involves maximizing the intensity of the illuminating light source and minimizing any noise sources. Limits to the light source intensity may arise from the availability of a stable high-power laser or from damage to the system being measured. For example, we describe here a scanning confocal polarization microscope designed to image the dynamics of nerve networks. In this case the light intensity limit is set by several factors, including the scanning rate, the required response time and damage limits of the biological system. Assuming a stable experimental configuration for the interferometer and light source, the limiting noise source for visible light interferometry is shot-noise associated with the quantum state of the light inputs to the interferometer. Shot-noise can be thought of as arising from vacuum fluctuations entering the dark input port of the interferometer.(1) These vacuum field fluctuations combine with the light entering the other port to cause shot-noise in the detected photocurrent at the output ports of the interferometer. This shot-noise current normally limits the measured phase variance Δϕ to a value of 1/N where N is the average number of photons detected in a measurement interval. We describe an experiment which demonstrates that this shot-noise limit can be improved by injecting squeezed vacuum into the normally dark input port.(2) In this case the phase variance is reduced below the 1/N limit by the degree of squeezing. In contrast to early experiments,(2) we are now operating the interferometer in a dark fringe mode(3–5) in order to avoid setting a limit to the light level caused by detector saturation (near 1 mW).