Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Two-photon quantum interference in a Michelson interferometer

Satoru Odate, Hai-bo Wang, Takayoshi Kobayashi

Published Dec 23, 2005• 11 citations
Publisher

Abstract

We have observed two-photon quantum interference in a Michelson interferometer. For the first time, we experimentally demonstrated two-photon quantum interference patterns, which show the transition from nonsubwavelength interference fringes to the general subwavelength interference. At the same time, a photon bunching effect was also shown by a postselection. The \ensuremath{\mid}1, 1⟩ state with a single photon in a mode corresponding to each arm of the interferometer was exclusively postselected by using path difference between two arms.

DOI
10.1103/physreva.72.063812

Related papers

Two-photon interference of temporally separated photons

Heonoh Kim, Sang Min Lee, Han Seb Moon

We present experimental demonstrations of two-photon interference involving temporally separated photons within two types of interferometers: a Mach-Zehnder interferometer and a polarization-based Michelson interferometer. The two-photon states are probabilistically prepared in a symmetrically superposed state within the two interferometer arms by introducing a large time delay between two input photons; this state is composed of two temporally separated photons, which are in two different or the same spatial modes. We then observe two-photon interference fringes involving both the Hong-Ou-Mandel interference effect and the interference of path-entangled two-photon states simultaneously in a single interferometric setup. The observed two-photon interference fringes provide simultaneous observation of the interferometric properties of the single-photon and two-photon wavepackets. The observations can also facilitate a more comprehensive understanding of the origins of the interference phenomena arising from spatially bunched/anti-bunched two-photon states comprised of two temporally separated photons within the interferometer arms.

arXiv:1607.03678•Scientific Reports•Oct 6, 2016•32 citations

Two-photon interferences of nondegenerate photon pairs from Doppler-broadened atomic ensemble

Jiho Park, Heonoh Kim, Han Seb Moon

Rb atoms. When two photons with different wavelengths are incident on a polarization-based Michelson interferometer, two kinds of two-photon superposition states, the frequency-entangled state and dichromatic path-entangled state depending on whether the two photons are in different paths or in the same path, are probabilistically generated within the interferometer arms. Hong-Ou-Mandel-type interference fringes resulting from the frequency-entangled state are observed over the range of the single-photon coherence length, following introduction of a coarse path-length difference between the two interferometer arms and employing phase randomization. When the interferometer is highly phase-sensitive without phase randomization, a phase super-resolved fringe arising from the dichromatic path-entangled state is observed, both with and without the accompanying one-photon interference fringes.

Optics Express•Dec 8, 2017•9 citations

Coherence measurements with the two-photon Michelson interferometer

Dorilian Lopez-Mago, Lukáš Novotný

The interference of entangled photon pairs permits the study of the fundamental properties of quantum mechanics. The process is also finding practical applications in optical imaging. The Michelson interferometer provides an elegant means for characterizing the degree of two-photon entanglement, but the technique has not yet been described and analyzed in detail. Here we provide a full description of the interference of collinear down-converted photons in a Michelson interferometer. We explain the basic elements that characterize the interference pattern and complement the theory with experimental measurements. The two-photon Michelson interferometer can be used in quantum optical coherence tomography for dispersion-free imaging and localization.

Physical Review A•Aug 14, 2012•28 citations

Single-Photon Michelson's Interference ExperimentsUsing Pulsed Light

Shuichi Kinoshita, Takashi Kushida

A Michelson's interference experiment has been performed using a single-photon counting under the condition that at most one photon is present in the interferometer. A CW mode-locked Ar + laser has been employed as a light source. It has been found that the dependence of the visibility on the difference in the two arm lengths measured on a single-photon level is the same as that for the multi-photon interference experiment. This dependence and the distribution of the photon detection time measured simultaneously by a time-correlated single-photon counting method have been found to be explained well by assuming that all the photons in the mode-locked laser pulse examined have the same temporal and spectral characteristics. A quantum mechanical analysis of this kind of experiment is also presented.

Journal of the Physical Society of Japan•Sep 15, 1991•3 citations

Correlated two-photon interference in a dual-beam Michelson interferometer

Paul G. Kwiat, William A. Vareka, C. K. Hong +2 more

We report on an interference effect arising from a two-photon entangled state produced in a potassium dihydrogen phosphate (KDP) crystal pumped by an ultraviolet argon-ion laser. Two conjugate beams of signal and idler photons were injected in a parallel configuration into a single Michelson interferometer, and detected separately by two photomultipliers, while the difference in its arm lengths was slowly scanned. The coincidence rate exhibited fringes with a visibility of nearly 50%, and a period given by half the ultraviolet (not the signal or idler) wavelength, while the singles rate exhibited no fringes.

Physical Review A•Mar 1, 1990•209 citations

EPR experiment and 2-photon interferometry: Report of a 2-photon interference experiment

Yanhua H. Shih, Morton H. Rubin, Alexander V. Sergienko

After a very brief review of the historical Einstein, Podolsky, and Rosen (EPR) experiments, a new two-photon interference type EPR experiment is reported. A two-photon state was generated by optical parametric down conversion. Pairs of light quanta with degenerate frequency but divergent directions of propagation were sent to two independent Michelson interferometers. First and second order interference effectors were studied. Different than other reports, we observed that the second order interference visibility vanished when the optical path difference of the interferometers were much less than the coherence length of the pumping laser beam. However, we also observed that the second order interference behaved differently depending on whether the interferometers were set at equal or different optical path differences.

•Feb 1, 1992•0 citations
We have observed two-photon quantum interference in a Michelson interferometer. For the first time, we experimentally demonstrated two-photon quantum interference patterns, which show the transition from nonsubwavelength interference fringes to the general subwavelength interference. At the same time, a photon bunching effect was also shown by a postselection. The \ensuremath{\mid}1, 1⟩ state with a single photon in a mode corresponding to each arm of the interferometer was exclusively postselected by using path difference between two arms.
We present experimental demonstrations of two-photon interference involving temporally separated photons within two types of interferometers: a Mach-Zehnder interferometer and a polarization-based Michelson interferometer. The two-photon states are probabilistically prepared in a symmetrically superposed state within the two interferometer arms by introducing a large time delay between two input photons; this state is composed of two temporally separated photons, which are in two different or the same spatial modes. We then observe two-photon interference fringes involving both the Hong-Ou-Mandel interference effect and the interference of path-entangled two-photon states simultaneously in a single interferometric setup. The observed two-photon interference fringes provide simultaneous observation of the interferometric properties of the single-photon and two-photon wavepackets. The observations can also facilitate a more comprehensive understanding of the origins of the interference phenomena arising from spatially bunched/anti-bunched two-photon states comprised of two temporally separated photons within the interferometer arms.
Rb atoms. When two photons with different wavelengths are incident on a polarization-based Michelson interferometer, two kinds of two-photon superposition states, the frequency-entangled state and dichromatic path-entangled state depending on whether the two photons are in different paths or in the same path, are probabilistically generated within the interferometer arms. Hong-Ou-Mandel-type interference fringes resulting from the frequency-entangled state are observed over the range of the single-photon coherence length, following introduction of a coarse path-length difference between the two interferometer arms and employing phase randomization. When the interferometer is highly phase-sensitive without phase randomization, a phase super-resolved fringe arising from the dichromatic path-entangled state is observed, both with and without the accompanying one-photon interference fringes.
The interference of entangled photon pairs permits the study of the fundamental properties of quantum mechanics. The process is also finding practical applications in optical imaging. The Michelson interferometer provides an elegant means for characterizing the degree of two-photon entanglement, but the technique has not yet been described and analyzed in detail. Here we provide a full description of the interference of collinear down-converted photons in a Michelson interferometer. We explain the basic elements that characterize the interference pattern and complement the theory with experimental measurements. The two-photon Michelson interferometer can be used in quantum optical coherence tomography for dispersion-free imaging and localization.
A Michelson's interference experiment has been performed using a single-photon counting under the condition that at most one photon is present in the interferometer. A CW mode-locked Ar + laser has been employed as a light source. It has been found that the dependence of the visibility on the difference in the two arm lengths measured on a single-photon level is the same as that for the multi-photon interference experiment. This dependence and the distribution of the photon detection time measured simultaneously by a time-correlated single-photon counting method have been found to be explained well by assuming that all the photons in the mode-locked laser pulse examined have the same temporal and spectral characteristics. A quantum mechanical analysis of this kind of experiment is also presented.
We report on an interference effect arising from a two-photon entangled state produced in a potassium dihydrogen phosphate (KDP) crystal pumped by an ultraviolet argon-ion laser. Two conjugate beams of signal and idler photons were injected in a parallel configuration into a single Michelson interferometer, and detected separately by two photomultipliers, while the difference in its arm lengths was slowly scanned. The coincidence rate exhibited fringes with a visibility of nearly 50%, and a period given by half the ultraviolet (not the signal or idler) wavelength, while the singles rate exhibited no fringes.
After a very brief review of the historical Einstein, Podolsky, and Rosen (EPR) experiments, a new two-photon interference type EPR experiment is reported. A two-photon state was generated by optical parametric down conversion. Pairs of light quanta with degenerate frequency but divergent directions of propagation were sent to two independent Michelson interferometers. First and second order interference effectors were studied. Different than other reports, we observed that the second order interference visibility vanished when the optical path difference of the interferometers were much less than the coherence length of the pumping laser beam. However, we also observed that the second order interference behaved differently depending on whether the interferometers were set at equal or different optical path differences.