Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

John Hall Symposium

QUANTUM INTERFEROMETRY WITH ULTRASTABLE TWIN BEAMS

Olivier Pfister, Sheng Feng

Published Mar 28, 2006• 0 citations
Publisher

Abstract

Laser stabilization methods learned by the authors from Jan Hall are applied to control a nondegenerate optical parametric oscillator above threshold in order to generate frequency-stable quantum twin beams. These beams are used to test quantum noise reduction in interferometric measurements and heterodyne polarimetry is demonstrated at 4.8 dB below the shot noise limit.

DOI
10.1142/9789812773845_0017

Related papers

Quantum Interference of Correlated Boson Fields: Homodyne and Heterodyne Optical Interferometry below the Shot Noise

Sheng Feng

Quantum interference of twin optical beams, a typical example of correlated boson fields, is of great interest from the viewpoint of both fundamental and applied physics. Intensity correlated optical beams and their quantum interference bring the possibility of performing sub-shot-noise interferometry experiments which yield high-sensitivity in practical applications. A type-II doubly resonant optical parametric oscillator (OPO) has been built for research in quantum optics, to provide a source of ultrastable quantum correlated (twin) optical beams with continuously tunable frequency difference from zero up to several THz. Three servo loops have been built to control the frequency difference of the twin optical beams and sub-hertz stability has been achieved for frequency difference up to 100MHz. In particular, frequency degenerate twin beams are indistinguishable macroscopic quantum systems. A series of experimental results has been produced with these OPO-generated ultrastable twin beams: the observation of the generalized Hong-Ou-Mandel interference of untrastable twin optical beams, sub-shot-noise homodyne interferometry, and sub-shot-noise heterodyne polarimetry. Note: Abstract extracted from PDF text

•May 1, 2005•0 citations

Sub-shot-noise heterodyne polarimetry

Sheng Feng, Olivier Pfister

We report an experimental demonstration of a heterodyne polarization rotation measurement with a noise floor 4.8 dB below the optical shot noise by use of classically phase-locked quantum twin beams emitted above threshold by an ultrastable type II Na:KTP cw optical parametric oscillator. We believe that this is the largest noise reduction achieved to date in optical phase-difference measurements.

arXiv:quant-ph/0406031•Optics Letters•Dec 1, 2004•16 citations

Observation of Quantum Noise Reduction on Twin Laser Beams

A. Heidmann, R. J. Horowicz, Serge Reynaud +3 more

We have used a two-mode optical parametric oscillator operating above threshold to generate high-intensity twin beams which exhibit quantum correlations. The noise power measured on the intensity difference between two such beams is reduced by 30% below the shot-noise limit. Noise reduction is observed over a broad range of frequencies.

Physical Review Letters•Nov 30, 1987•632 citations

Photon noise reduction by optoelectronic correction using a nondegenerate optical parametric oscillator

Claude Fabre, Jerome C. Mertz, E. Giacobino +2 more

It has been recently shown theoretically1 and experimentally2 that nondegenerate optical parametric oscillators generate above threshold intense and highly correlated twin beams. More precisely, the noise on the difference between the intensities of the two beams is well below the shot noise for noise frequencies inside the cavity bandwidth. An application of this quantum correlation is to measure the intensity of one beam and use this information to correct the fluctuations of the other beam by optoelectronic means (photodiode, amplifier, and electrooptic modulator). The correction may be applied either on the pumping beam (feedback correction) or directly on the twin beam itself (feed-forward correction).

Annual Meeting Optical Society of America•Jan 1, 1989•0 citations

Improvements in the observed intensity correlation of optical parametric oscillator twin beams

Jerome C. Mertz, Thierry Debuisschert, A. Heidmann +2 more

We report an observed quantum noise reduction of 86% (8.5 dB) near 3 MHz in the intensity difference between the twin beams generated by a nondegenerate type II optical parametric oscillator operating above threshold.

Optics Letters•Aug 15, 1991•108 citations

Sub-shot-noise high-sensitivity spectroscopy with optical parametric oscillator twin beams

P. H. Souto Ribeiro, Catherine Schwob, Agnès Maître +1 more

Nondegenerate optical parametric oscillators generate above-threshold signal and idler beams that have intensity fluctuations correlated at the quantum level (twin beams). We describe what is to our knowledge the first high-sensitivity spectroscopy experiment using twin beams emitted by a cw optical parametric oscillator: a very weak two-photon absorption signal, in the 10(-7) range, is recorded on the 4S(1/2)-5S(1/2) transition of atomic potassium with a noise background that is reduced by 1.9 dB with respect to the shot-noise limit of the light used in the experiment.

Optics Letters•Dec 15, 1997•117 citations
Laser stabilization methods learned by the authors from Jan Hall are applied to control a nondegenerate optical parametric oscillator above threshold in order to generate frequency-stable quantum twin beams. These beams are used to test quantum noise reduction in interferometric measurements and heterodyne polarimetry is demonstrated at 4.8 dB below the shot noise limit.
Quantum interference of twin optical beams, a typical example of correlated boson fields, is of great interest from the viewpoint of both fundamental and applied physics. Intensity correlated optical beams and their quantum interference bring the possibility of performing sub-shot-noise interferometry experiments which yield high-sensitivity in practical applications. A type-II doubly resonant optical parametric oscillator (OPO) has been built for research in quantum optics, to provide a source of ultrastable quantum correlated (twin) optical beams with continuously tunable frequency difference from zero up to several THz. Three servo loops have been built to control the frequency difference of the twin optical beams and sub-hertz stability has been achieved for frequency difference up to 100MHz. In particular, frequency degenerate twin beams are indistinguishable macroscopic quantum systems. A series of experimental results has been produced with these OPO-generated ultrastable twin beams: the observation of the generalized Hong-Ou-Mandel interference of untrastable twin optical beams, sub-shot-noise homodyne interferometry, and sub-shot-noise heterodyne polarimetry. Note: Abstract extracted from PDF text
It has been recently shown theoretically1 and experimentally2 that nondegenerate optical parametric oscillators generate above threshold intense and highly correlated twin beams. More precisely, the noise on the difference between the intensities of the two beams is well below the shot noise for noise frequencies inside the cavity bandwidth. An application of this quantum correlation is to measure the intensity of one beam and use this information to correct the fluctuations of the other beam by optoelectronic means (photodiode, amplifier, and electrooptic modulator). The correction may be applied either on the pumping beam (feedback correction) or directly on the twin beam itself (feed-forward correction).
Nondegenerate optical parametric oscillators generate above-threshold signal and idler beams that have intensity fluctuations correlated at the quantum level (twin beams). We describe what is to our knowledge the first high-sensitivity spectroscopy experiment using twin beams emitted by a cw optical parametric oscillator: a very weak two-photon absorption signal, in the 10(-7) range, is recorded on the 4S(1/2)-5S(1/2) transition of atomic potassium with a noise background that is reduced by 1.9 dB with respect to the shot-noise limit of the light used in the experiment.