Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantum Electronics and Laser Science Conference

Highly Efficient "interaction Free" Measurements In A Fabry-perot Resonator

Anders Karlsson, Gunnar G. Bjork, E. Goobar, Tedros Tsegaye, Erik Forsberg

Published Jan 1, 1997• 0 citations
OpenAlex

Related papers

The effect of nonlinear generation of high-frequency optical noise in a Fabry-Perot resonator

Andrey N. Morozov, В. О. Гладышев

Pisma v Zhurnal Tekhnischeskoi Fiziki•Mar 1, 1990•0 citations

Nonlinear dynamics in a Fabry-Perot resonator

Luigi A. Lugiato, Lorenzo M. Narducci

The European Physical Journal B•Mar 1, 1988•41 citations

High-efficiency interaction-free measurements using a stabilized Fabry-Perot cavity

Naoto Namekata, Shuichiro Inoue

Using a Fabry-Perot cavity with high transmittivity, it is possible to realize high-efficiency interaction-free measurements. In the scheme, it is required to stabilize the Fabry-Perot cavity when the measurements are performed. We have developed a stabilized Fabry-Perot cavity, and demonstrated the interaction-free measurements with the efficiency of 88 %.

Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR)•Jun 21, 2004•0 citations

Nonlinear dynamics in a Fabry-Perot resonator (A)

Luigi Lugiato, Ellen Dougherty, Lorenzo M. Narducci +1 more

Journal of the Optical Society of America B•Feb 1, 1987•0 citations

High-efficiency interaction-free measurements using a stabilized Fabry–Pérot cavity

Naoto Namekata, Shuichiro Inoue

Using a Fabry–Perot cavity with high transmittivity, we have realized high-efficiency interaction-free measurements. The required stability of the cavity was achieved by employing the Pound-Drever feedback scheme without disturbing the measurement. For both an absorbing and a transparent object, the probability of correctly determining the presence or absence of the object (the efficiency of the interaction-free measurement) was found to be 88%.

Journal of Physics B Atomic Molecular and Optical Physics•Jul 28, 2006•8 citations

Efficient interaction-free measurements in a high-finesse interferometer

Tedros Tsegaye, E. Goobar, Anders Karlsson +3 more

Interaction-free measurements were realized using a high-finesse Fabry-P\'erot cavity as a measurement apparatus. A figure of merit based on the maximum likelihood estimation, which takes into account real experimental conditions, is used to analyze the efficiency of this measurement scheme. The probability of detecting the presence of an object within the cavity without any photons actually ``hitting'' the object was approximately 85%. The probability of asserting the absence of the object was approximately 75%. Assuming that the a priori probability of the object being present was 1/2, the likelihood of knowing whether the object was present or not was 80%. The obtained results and the limitations of our setup are discussed.

Physical Review A•May 1, 1998•54 citations
Interaction-free measurements were realized using a high-finesse Fabry-P\'erot cavity as a measurement apparatus. A figure of merit based on the maximum likelihood estimation, which takes into account real experimental conditions, is used to analyze the efficiency of this measurement scheme. The probability of detecting the presence of an object within the cavity without any photons actually ``hitting'' the object was approximately 85%. The probability of asserting the absence of the object was approximately 75%. Assuming that the a priori probability of the object being present was 1/2, the likelihood of knowing whether the object was present or not was 80%. The obtained results and the limitations of our setup are discussed.