Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

NASA Tech Briefs

Ultra-Stable Superconducting-Maser Oscillator

D. M. Strayer, G.J. Dick

Published Jun 1, 1989• 0 citations
OpenAlex

Abstract

Unprecedented stability of frequency in superconducting, triple-cavity ruby maser oscillator achieved by incorporation of amplitude-control subsystem. New design enhances ultra-stable measurements of time by reducing fluctuations to 2 X 10 to negative 19th power routinely, and to as little as 10 to negative 20th power in exceptional cases. Currents induced in superconducting pickup coil by changes in magnetic field in ruby. Currents from coil fed to superconducting quantum-interference device (SQUID) magnetometer, output used to generate control signal for electronically variable attenuator. Attenuator varies pump-signal amplitude in response to magnetic-field fluctuations in ruby. Very high feedback-loop gain used for sensitivity of control and adequate compensation of fluctuations.

Related papers

Adiabatic Rapid Passage in Ruby at 8 mm Wavelengths†

J. S. Thorp, J H Pace, David Sampson

An investigation of adiabatic rapid passage has been made in ruby at 8 mm wavelengths. Performance data are given on a two-level ruby maser operated both as a pulsed amplifier and as an oscillator at these wavelengths. When amplifying, values of gain and bandwidth of up to about 14 ds and 10 Mc/ s at 1-4° k were obtained, giving root gain-bandwidth products of up to about 50 Mc/ s. In preliminary experiments using the maser as an oscillator output powers of about 70 / z/ v at 33-1 Gc/ s were obtained at 1. 4° K. The inversion technique used, which incorporates magnetic field modulation with the use of the crystal as a cavity, could be readily scaled to considerably higher frequencies.

Journal of Electronics and Control•Jan 1, 1961•4 citations

Broadband SQUID amplifiers for photonic applications

Vladimir Polushkin, D. Glowacka, R. Hart +1 more

The dynamics and noise of a dc SQUID (the Superconducting Quantum Interference Device), with the McCumber parameter /spl beta//sub c/=2/spl pi/R/sup 2/l/sub c/C//spl Phi//sub 0/ close to the unity (where I/sub c/, R, C is the critical current, the shunt resistance and the capacitance of the Josephson junctions comprising the SQUID, respectively, /spl Phi//sub 0/=2.07 10/sup -15/ Wb is the magnetic flux quantum) integrated with a planar spiral input coil, have been experimentally studied. The length of the spiral input coil was chosen so as to match its /spl lambda//4 microwave resonance frequency to the plasma resonance frequency of the SQUID. The input coil resonance is found to enhance the overall quality factor Q of the Josephson oscillations in the SQUID and, as a result, to increase the dynamic resistance R/sub d/ and the gradient of the flux-to-voltage characteristics, /spl delta/V//spl delta//spl Phi/, without hysteresis. A dc SQUID with a loop inductance L=30.5 pH, /spl beta//sub c/=0.72, and a 6 turn input coil demonstrated a non-distorted quasi-sinusoidal flux-to-voltage transfer function with an exceptionally large modulation depth of 140 /spl mu/V peak-to-peak. The spectral density of the magnetic flux noise was as low as 3.5/spl times/10/sup -7/ /spl Phi//sub 0//Hz/sup 1/2/ in the double stage configuration, measured at a temperature 4.2 K using direct read out electronics. In combination with an intermediary transformer, the current resolution of the SQUID is as low as 1.25 pA/Hz/sup 1/2/ with an input coil inductance of 100 nH.

IEEE Transactions on Applied Superconductivity•Jun 1, 1999•1 citation

Radio-Frequency Oscillator for HTS RF SQUID Magnetometer

Jing Zhao

In order to improve magnetic field sensitivity and stability of the high-temperature RF SQUID(Rradio-Frequency Superconducting Quantum Interference Devices) magnetometer,a radio-frequency oscillator used to provide bias signal to resonant circuit of the superconducting quantum interference devices was designed.The voltage-controlled oscillator with adjustable continuously frequency was used as signal source,and radio-frequency signal attenuation circuit used to attenuate oscillation signal to meet the power requirements of the oscillation signal of the SQUID was also designed.The experiments showed that the oscillator can continuously produce adjustable 549.75~947 MHz radio-frequency signal,and the minimum signal power is-98.97 dBm,which meets the work requirements of the SQUID devices.

Journal of Jilin University•Jan 1, 2009•2 citations

Ultrastable Performance of the Superconducting Cavity Maser Oscillator at Short Measuring Times

R. T. Wang, G.J. Dick

•Jul 1, 1990•0 citations

Transient Dynamics of a Superconducting Nonlinear Oscillator

P. Bhupathi, Peter Groszkowski, M. P. DeFeo +3 more

Superconducting quantum interference devices (SQUIDs) are used across physics and engineering, from amplification to detecting tiny magnetic fields to quantum computing. In many applications the SQUID's steady-state response is of interest, but here the authors measure and model the $t\phantom{\rule{0}{0ex}}r\phantom{\rule{0}{0ex}}a\phantom{\rule{0}{0ex}}n\phantom{\rule{0}{0ex}}s\phantom{\rule{0}{0ex}}i\phantom{\rule{0}{0ex}}e\phantom{\rule{0}{0ex}}n\phantom{\rule{0}{0ex}}t$ response to short bursts of radiation. The resulting ringdown oscillations in voltage decay over time, with a rich structure that may be particularly useful in discriminating weak magnetic fluxes---in qubits, for example.

arXiv:1504.06883•Physical Review Applied•Feb 1, 2016•11 citations

Single-quadrature quantum magnetometry in cavity electromagnonics

Mehri Sadat Ebrahimi, Ali Motazedifard, M. Bagheri Harouni

A scheme of an ultrasensitive magnetometer in the cavity quantum electromagnonics is proposed, where the intracavity microwave mode is coupled to a magnonic mode via magnetic dipole interaction. It is shown that by driving both magnonic and microwave modes with external classical fields and controlling the system parameters, one can reduce the added noise of magnetic field measurement below the standard quantum limit (SQL). Surprisingly, we show that beyond the rotating wave approximation (RWA), not only can the added noise be suppressed but also the output cavity response to the input signal can be substantially amplified in order to achieve a precise magnetic-field measurement. The estimated theoretical sensitivity of the proposed magnetic amplifier-sensor is approximately on the order of ${10}^{\ensuremath{-}18}\phantom{\rule{0.28em}{0ex}}\mathrm{T}/\sqrt{\mathrm{Hz}}$, which is competitive compared to the current state-of-the-art magnetometers like superconducting quantum interference devices (SQUIDs) and atomic magnetometers. The advantages of the proposed sensor in comparison with the other magnetometers is its high sensitivity at room temperature, sensing in a wide range of frequencies up to MHz, and its capability for signal-response amplification.

arXiv:2011.06081•Physical Review A•Jun 10, 2021•50 citations
Unprecedented stability of frequency in superconducting, triple-cavity ruby maser oscillator achieved by incorporation of amplitude-control subsystem. New design enhances ultra-stable measurements of time by reducing fluctuations to 2 X 10 to negative 19th power routinely, and to as little as 10 to negative 20th power in exceptional cases. Currents induced in superconducting pickup coil by changes in magnetic field in ruby. Currents from coil fed to superconducting quantum-interference device (SQUID) magnetometer, output used to generate control signal for electronically variable attenuator. Attenuator varies pump-signal amplitude in response to magnetic-field fluctuations in ruby. Very high feedback-loop gain used for sensitivity of control and adequate compensation of fluctuations.
An investigation of adiabatic rapid passage has been made in ruby at 8 mm wavelengths. Performance data are given on a two-level ruby maser operated both as a pulsed amplifier and as an oscillator at these wavelengths. When amplifying, values of gain and bandwidth of up to about 14 ds and 10 Mc/ s at 1-4° k were obtained, giving root gain-bandwidth products of up to about 50 Mc/ s. In preliminary experiments using the maser as an oscillator output powers of about 70 / z/ v at 33-1 Gc/ s were obtained at 1. 4° K. The inversion technique used, which incorporates magnetic field modulation with the use of the crystal as a cavity, could be readily scaled to considerably higher frequencies.
The dynamics and noise of a dc SQUID (the Superconducting Quantum Interference Device), with the McCumber parameter /spl beta//sub c/=2/spl pi/R/sup 2/l/sub c/C//spl Phi//sub 0/ close to the unity (where I/sub c/, R, C is the critical current, the shunt resistance and the capacitance of the Josephson junctions comprising the SQUID, respectively, /spl Phi//sub 0/=2.07 10/sup -15/ Wb is the magnetic flux quantum) integrated with a planar spiral input coil, have been experimentally studied. The length of the spiral input coil was chosen so as to match its /spl lambda//4 microwave resonance frequency to the plasma resonance frequency of the SQUID. The input coil resonance is found to enhance the overall quality factor Q of the Josephson oscillations in the SQUID and, as a result, to increase the dynamic resistance R/sub d/ and the gradient of the flux-to-voltage characteristics, /spl delta/V//spl delta//spl Phi/, without hysteresis. A dc SQUID with a loop inductance L=30.5 pH, /spl beta//sub c/=0.72, and a 6 turn input coil demonstrated a non-distorted quasi-sinusoidal flux-to-voltage transfer function with an exceptionally large modulation depth of 140 /spl mu/V peak-to-peak. The spectral density of the magnetic flux noise was as low as 3.5/spl times/10/sup -7/ /spl Phi//sub 0//Hz/sup 1/2/ in the double stage configuration, measured at a temperature 4.2 K using direct read out electronics. In combination with an intermediary transformer, the current resolution of the SQUID is as low as 1.25 pA/Hz/sup 1/2/ with an input coil inductance of 100 nH.
In order to improve magnetic field sensitivity and stability of the high-temperature RF SQUID(Rradio-Frequency Superconducting Quantum Interference Devices) magnetometer,a radio-frequency oscillator used to provide bias signal to resonant circuit of the superconducting quantum interference devices was designed.The voltage-controlled oscillator with adjustable continuously frequency was used as signal source,and radio-frequency signal attenuation circuit used to attenuate oscillation signal to meet the power requirements of the oscillation signal of the SQUID was also designed.The experiments showed that the oscillator can continuously produce adjustable 549.75~947 MHz radio-frequency signal,and the minimum signal power is-98.97 dBm,which meets the work requirements of the SQUID devices.
Superconducting quantum interference devices (SQUIDs) are used across physics and engineering, from amplification to detecting tiny magnetic fields to quantum computing. In many applications the SQUID's steady-state response is of interest, but here the authors measure and model the $t\phantom{\rule{0}{0ex}}r\phantom{\rule{0}{0ex}}a\phantom{\rule{0}{0ex}}n\phantom{\rule{0}{0ex}}s\phantom{\rule{0}{0ex}}i\phantom{\rule{0}{0ex}}e\phantom{\rule{0}{0ex}}n\phantom{\rule{0}{0ex}}t$ response to short bursts of radiation. The resulting ringdown oscillations in voltage decay over time, with a rich structure that may be particularly useful in discriminating weak magnetic fluxes---in qubits, for example.
A scheme of an ultrasensitive magnetometer in the cavity quantum electromagnonics is proposed, where the intracavity microwave mode is coupled to a magnonic mode via magnetic dipole interaction. It is shown that by driving both magnonic and microwave modes with external classical fields and controlling the system parameters, one can reduce the added noise of magnetic field measurement below the standard quantum limit (SQL). Surprisingly, we show that beyond the rotating wave approximation (RWA), not only can the added noise be suppressed but also the output cavity response to the input signal can be substantially amplified in order to achieve a precise magnetic-field measurement. The estimated theoretical sensitivity of the proposed magnetic amplifier-sensor is approximately on the order of ${10}^{\ensuremath{-}18}\phantom{\rule{0.28em}{0ex}}\mathrm{T}/\sqrt{\mathrm{Hz}}$, which is competitive compared to the current state-of-the-art magnetometers like superconducting quantum interference devices (SQUIDs) and atomic magnetometers. The advantages of the proposed sensor in comparison with the other magnetometers is its high sensitivity at room temperature, sensing in a wide range of frequencies up to MHz, and its capability for signal-response amplification.