Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

HIGH PRECISION PHOTOASSOCIATION SPECTROSCOPY OF ULTRA-COLD ALKALIS.

Eite Tiesinga, Paul S. Julienne

Published Jan 1, 1998• 0 citations
OpenAlex

Abstract

Author Institution: Atomic Physics Division, National Institute of Standards and Technology

Related papers

HIGH PRECISION MOLECULAR SPECTROSCOPY BY PHOTOASSOCIATION OF ULTRACOLD TRAPPED ATOMS

Paul S. Julienne

Author Institution: A267 Physics National Institute of Standards and Technology, Gaithersburg, MD 20899

•Jan 1, 1997•0 citations

High sensitive photoassociation spectroscopy based on modulated ultra-cold Cs atoms

L.R. Wang, Jie Ma, C.Y. Li +3 more

Applied Physics B•Aug 7, 2007•10 citations

CONTROL OF COHERENT LIGHT AND ITS APPLICATIONS TO MOLECULAR SPECTROSCOPY

Jun Ye

Author Institution: JILA, National Institute of Standards and Technology and University of Colorado

•Jan 1, 2004•0 citations

Photoassociation spectroscopy of cold atoms in a bright atomic beam

Jaime Ramirez-Serrano

•Sep 1, 2001•0 citations

Precise quantum measurement of vacuum with cold atoms

Daniel S. Barker, B. P. Acharya, James A. Fedchak +5 more

We describe the cold-atom vacuum standards (CAVS) under development at the National Institute of Standards and Technology (NIST). The CAVS measures pressure in the ultra-high and extreme-high vacuum regimes by measuring the loss rate of sub-millikelvin sensor atoms from a magnetic trap. Ab initio quantum scattering calculations of cross sections and rate coefficients relate the density of background gas molecules or atoms to the loss rate of ultra-cold sensor atoms. The resulting measurement of pressure through the ideal gas law is traceable to the second and the kelvin, making it a primary realization of the pascal. At NIST, two versions of the CAVS have been constructed: a laboratory standard used to achieve the lowest possible uncertainties and pressures, and a portable version that is a potential replacement for the Bayard-Alpert ionization gauge. Both types of CAVSs are connected to a combined extreme-high vacuum flowmeter and dynamic expansion system to enable sensing of a known pressure of gas. In the near future, we anticipate being able to compare the laboratory scale CAVS, the portable CAVS, and the flowmeter/dynamic expansion system to validate the operation of the CAVS as both a standard and vacuum gauge.

Review of Scientific Instruments•Dec 1, 2022•18 citations

PENDULAR STATES AND IVR

G. T. Fraser, Juan Ortigoso, Brooks H. Pate

Author Institution: Optical Technology Division, National Institue of Standards and Technology; Inst. Estructura de la Materia, CSIC, National Institue of Standards and Technology; Department of Chemistry, University of Virginia

•Jan 1, 1996•0 citations
We describe the cold-atom vacuum standards (CAVS) under development at the National Institute of Standards and Technology (NIST). The CAVS measures pressure in the ultra-high and extreme-high vacuum regimes by measuring the loss rate of sub-millikelvin sensor atoms from a magnetic trap. Ab initio quantum scattering calculations of cross sections and rate coefficients relate the density of background gas molecules or atoms to the loss rate of ultra-cold sensor atoms. The resulting measurement of pressure through the ideal gas law is traceable to the second and the kelvin, making it a primary realization of the pascal. At NIST, two versions of the CAVS have been constructed: a laboratory standard used to achieve the lowest possible uncertainties and pressures, and a portable version that is a potential replacement for the Bayard-Alpert ionization gauge. Both types of CAVSs are connected to a combined extreme-high vacuum flowmeter and dynamic expansion system to enable sensing of a known pressure of gas. In the near future, we anticipate being able to compare the laboratory scale CAVS, the portable CAVS, and the flowmeter/dynamic expansion system to validate the operation of the CAVS as both a standard and vacuum gauge.