Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Al+ Optical Clocks for Fundamental Physics and Geodesy

James Chin-wen Chou

Published Jul 13, 2011• 0 citations
OpenAlex

Abstract

Laser-cooled trapped atoms have long been recognized as potentially very accurate frequency standards for clocks. Ultimate accuracies of 10-18 to 10-19 appear possible, limited by the time-dilation of trapped ions that move at laser-cooled velocities. The Al+ ion is an attractive candidate for high accuracy, owing to its narrow electronic transition in the optical regime and low sensitivity to ambient field perturbations. Precision spectroscopy on Al+ is enabled by quantum information techniques. With Al+ “quantum-logic” clocks, the current accuracy of 8.6×10-18 has enabled a geo-potential-difference measurement that detected a height change of 37±17 cm due to the gravitational red-shift. We have also observed quantum coherence between two Al+ ions with a record Q-factor of 3.4×1016, and compared the Al+ resonance frequency to that of a single Hg+ ion to place limits on the temporal variation of the fine-structure constant.

Related papers

Direct Laser Cooling Al${}^{+}$ Ion Optical Clocks

Jie Zhang, Ke Deng, Jun Luo +1 more

The Al ion optical clock is a very promising optical frequency standard candidate due to its extremely small black-body radiation shift. It has been successfully demonstrated with the indirect cooled, quantum-logic-based spectroscopy technique. Its accuracy is limited by second-order Doppler shift, and its stability is limited by the number of ions that can be probed in quantum logic processing. We propose a direct laser cooling scheme of Al ion optical clocks where both the stability and accuracy of the clocks are greatly improved. In the proposed scheme, two Al traps are utilized. The first trap is used to trap a large number of Al ions to improve the stability of the clock laser, while the second trap is used to trap a single Al ion to provide the ultimate accuracy. Both traps are cooled with a continuous wave 167 nm laser. The expected clock laser stability can reach . For the second trap, in addition to 167 nm laser Doppler cooling, a second stage pulsed 234 nm two-photon cooling laser is utilized to further improve the accuracy of the clock laser. The total systematic uncertainty can be reduced to about . The proposed Al ion optical clock has the potential to become the most accurate and stable optical clock .

arXiv:1609.03667•Chinese Physics Letters•May 1, 2017•17 citations

Frequency Comparison of Two High-Accuracy Al + Optical Clocks

C. W. Chou, David B. Hume, Jeroen C. J. Koelemeij +2 more

We have constructed an optical clock with a fractional frequency inaccuracy of 8.6x10{-18}, based on quantum logic spectroscopy of an Al+ ion. A simultaneously trapped Mg+ ion serves to sympathetically laser cool the Al+ ion and detect its quantum state. The frequency of the {1}S{0}<-->{3}P{0} clock transition is compared to that of a previously constructed Al+ optical clock with a statistical measurement uncertainty of 7.0x10{-18}. The two clocks exhibit a relative stability of 2.8x10{-15}tau{-1/2}, and a fractional frequency difference of -1.8x10{-17}, consistent with the accuracy limit of the older clock.

arXiv:0911.4527•Physical Review Letters•Feb 17, 2010•917 citations

Research progress of Al$^{+}$ ion optical frequency standard based on quantum logic technique

Kui Liu, Xiaohui Shi, Ke Deng +4 more

Optical atomic clocks have many applications in the definition of the time and the length, measurement of fundamental constants and their potential variations with time, testing of relativity, very long baseline interferometry, geodesy, and global navigation satellite systems. An optical clock consists of three parts: ultra-stable laser, frequency comb and trapped ions or atoms. The accuracy of optical atomic clocks can be affected by Doppler shift, Zeeman shift, Stark shift, collision shift, blackbody radiation (BBR) shift, etc. The BBR shift is very difficult to be characterized and controlled. Among all optical atomic clocks under current development, Al$^+$ optical clock has the smallest BBR shift at a level of $4.0\times10^{-19}$, therefore the Al$^+$ is a promising ion for high-accuracy optical frequency standard. In this article we give a review on the three parts of optical frequency standards, the basic working principle of Al$^+$ ion optical frequency standard based on quantum logic technique, and research progress of an Al$^+$ optical clock under development at Huazhong University of Science and Technology.

Zhongguo kexue. Wulixue Lixue Tianwenxue•Jun 13, 2016•0 citations

Frequency metrology and clocks

Helen S. Margolis

Transitions between discrete energy levels in well-isolated atomic systems are highly reproducible and therefore make ideal references for highly accurate frequency standards or clocks. In particular, a single laser-cooled ion confined in a radiofrequency ion trap closely approximates the spectroscopic ideal of a particle at rest in a perturbation-free environment. Narrow optical transitions in such systems are therefore very promising for the realization of optical clocks with accuracy around 2 orders of magnitude higher than current microwave primary standards. In this paper the fundamental aspects, current performance and applications of trapped ion optical clocks are reviewed and the potential for future improvements is considered.

Journal of Physics B Atomic Molecular and Optical Physics•Jul 16, 2009•53 citations

Methods of quantum logic in ion frequency standards, quantum computers, and modern spectroscopy

Ksenia Yu. Khabarova, Ilia V. Zalivako, N. Kolachevsky

Today, precise laser control of the quantum states of single ions cooled to low temperatures in traps ensures significant progress in the development of such physical areas as optical and microwave frequency standards, quantum computing, and accurate measurements of transition frequencies to confirm fundamental physical theories.Pioneering ideas about the possibility of using lasers in the development of frequency standards, expressed in the 1960s by the Nobel laureate N G Basov, have enjoyed rapid development: the relative accuracy of frequency standards has reached the 18th decimal place, and the experimentally demonstrated coherence time of narrow optical transitions amounts to tens of seconds.The paper presents a selective review, as well as the results of research at the Lebedev Physical Institute, in the area of using elements of quantum logic in the action of coherent laser pulses on single ions.Also discussed is the use of quantum logic methods in optical clocks based on the Al + ion and the multiply charged Al + ion, and also in quantum computers based on Ca + and Yb + ions.

Physics-Uspekhi•Oct 1, 2022•12 citations

High Precision Spectroscopy of Strontium in an Optical Lattice: Towards a New Standard for Frequency and Time

Martin M. Boyd

Clocks based on optical transitions in ions and atoms are quickly moving to the forefront of the frequency standards field mainly because of the high spec-tral resolution, and therefore the potential stability and accuracy, which can be achieved. In this thesis a new optical clock based on neutral atoms trapped in an optical lattice is presented, demonstrating spectroscopy of the clock transition free of any lineshape or accuracy degradation due to atomic motion. The system simu-lates a single trapped ion clock, but allows use of thousands of atoms for improved signal to noise ratio, and clock stability. High accuracy can also be achieved as the lattice can be designed to shift the energy of the two atomic clock states equally, such that the transition frequency is unchanged. Strontium is a natural candidate for such a clock as it offers an extremely narrow optical transition (∼1 mHz) based on atomic states which are very insensitive to external fields. The strontium level structure allows efficient laser cooling to 1 µK with diode laser sources, and a con-venient wavelength of 813 nm for the zero-differential Stark shift optical lattice. The strontium lattice clock system has allowed observation of high signal-to-noise

•Jan 1, 2007•39 citations
Laser-cooled trapped atoms have long been recognized as potentially very accurate frequency standards for clocks. Ultimate accuracies of 10-18 to 10-19 appear possible, limited by the time-dilation of trapped ions that move at laser-cooled velocities. The Al+ ion is an attractive candidate for high accuracy, owing to its narrow electronic transition in the optical regime and low sensitivity to ambient field perturbations. Precision spectroscopy on Al+ is enabled by quantum information techniques. With Al+ “quantum-logic” clocks, the current accuracy of 8.6×10-18 has enabled a geo-potential-difference measurement that detected a height change of 37±17 cm due to the gravitational red-shift. We have also observed quantum coherence between two Al+ ions with a record Q-factor of 3.4×1016, and compared the Al+ resonance frequency to that of a single Hg+ ion to place limits on the temporal variation of the fine-structure constant.
Direct Laser Cooling Al+{}^{+}+ Ion Optical Clocks
The Al ion optical clock is a very promising optical frequency standard candidate due to its extremely small black-body radiation shift. It has been successfully demonstrated with the indirect cooled, quantum-logic-based spectroscopy technique. Its accuracy is limited by second-order Doppler shift, and its stability is limited by the number of ions that can be probed in quantum logic processing. We propose a direct laser cooling scheme of Al ion optical clocks where both the stability and accuracy of the clocks are greatly improved. In the proposed scheme, two Al traps are utilized. The first trap is used to trap a large number of Al ions to improve the stability of the clock laser, while the second trap is used to trap a single Al ion to provide the ultimate accuracy. Both traps are cooled with a continuous wave 167 nm laser. The expected clock laser stability can reach . For the second trap, in addition to 167 nm laser Doppler cooling, a second stage pulsed 234 nm two-photon cooling laser is utilized to further improve the accuracy of the clock laser. The total systematic uncertainty can be reduced to about . The proposed Al ion optical clock has the potential to become the most accurate and stable optical clock .
We have constructed an optical clock with a fractional frequency inaccuracy of 8.6x10{-18}, based on quantum logic spectroscopy of an Al+ ion. A simultaneously trapped Mg+ ion serves to sympathetically laser cool the Al+ ion and detect its quantum state. The frequency of the {1}S{0}<-->{3}P{0} clock transition is compared to that of a previously constructed Al+ optical clock with a statistical measurement uncertainty of 7.0x10{-18}. The two clocks exhibit a relative stability of 2.8x10{-15}tau{-1/2}, and a fractional frequency difference of -1.8x10{-17}, consistent with the accuracy limit of the older clock.
Research progress of Al+^{+}+ ion optical frequency standard based on quantum logic technique
Optical atomic clocks have many applications in the definition of the time and the length, measurement of fundamental constants and their potential variations with time, testing of relativity, very long baseline interferometry, geodesy, and global navigation satellite systems. An optical clock consists of three parts: ultra-stable laser, frequency comb and trapped ions or atoms. The accuracy of optical atomic clocks can be affected by Doppler shift, Zeeman shift, Stark shift, collision shift, blackbody radiation (BBR) shift, etc. The BBR shift is very difficult to be characterized and controlled. Among all optical atomic clocks under current development, Al+^++ optical clock has the smallest BBR shift at a level of 4.0×10−194.0\times10^{-19}4.0×10−19, therefore the Al+^++ is a promising ion for high-accuracy optical frequency standard. In this article we give a review on the three parts of optical frequency standards, the basic working principle of Al+^++ ion optical frequency standard based on quantum logic technique, and research progress of an Al+^++ optical clock under development at Huazhong University of Science and Technology.
Transitions between discrete energy levels in well-isolated atomic systems are highly reproducible and therefore make ideal references for highly accurate frequency standards or clocks. In particular, a single laser-cooled ion confined in a radiofrequency ion trap closely approximates the spectroscopic ideal of a particle at rest in a perturbation-free environment. Narrow optical transitions in such systems are therefore very promising for the realization of optical clocks with accuracy around 2 orders of magnitude higher than current microwave primary standards. In this paper the fundamental aspects, current performance and applications of trapped ion optical clocks are reviewed and the potential for future improvements is considered.
Today, precise laser control of the quantum states of single ions cooled to low temperatures in traps ensures significant progress in the development of such physical areas as optical and microwave frequency standards, quantum computing, and accurate measurements of transition frequencies to confirm fundamental physical theories.Pioneering ideas about the possibility of using lasers in the development of frequency standards, expressed in the 1960s by the Nobel laureate N G Basov, have enjoyed rapid development: the relative accuracy of frequency standards has reached the 18th decimal place, and the experimentally demonstrated coherence time of narrow optical transitions amounts to tens of seconds.The paper presents a selective review, as well as the results of research at the Lebedev Physical Institute, in the area of using elements of quantum logic in the action of coherent laser pulses on single ions.Also discussed is the use of quantum logic methods in optical clocks based on the Al + ion and the multiply charged Al + ion, and also in quantum computers based on Ca + and Yb + ions.
Clocks based on optical transitions in ions and atoms are quickly moving to the forefront of the frequency standards field mainly because of the high spec-tral resolution, and therefore the potential stability and accuracy, which can be achieved. In this thesis a new optical clock based on neutral atoms trapped in an optical lattice is presented, demonstrating spectroscopy of the clock transition free of any lineshape or accuracy degradation due to atomic motion. The system simu-lates a single trapped ion clock, but allows use of thousands of atoms for improved signal to noise ratio, and clock stability. High accuracy can also be achieved as the lattice can be designed to shift the energy of the two atomic clock states equally, such that the transition frequency is unchanged. Strontium is a natural candidate for such a clock as it offers an extremely narrow optical transition (∼1 mHz) based on atomic states which are very insensitive to external fields. The strontium level structure allows efficient laser cooling to 1 µK with diode laser sources, and a con-venient wavelength of 813 nm for the zero-differential Stark shift optical lattice. The strontium lattice clock system has allowed observation of high signal-to-noise