Softwaretechnik-Trends

The role of quantum noise in terahertz receivers

Sigfrid Yngvesson, E. Kollberg

Published Jan 1, 2004• 1 citation
OpenAlex

Abstract

We have revised and considerably extended our paper on quantum noise at the 13 th ISSTT. In the present paper we first review general quantum mechanical limits on the sensitivity of heterodyne receivers. We introduce the ideal broad band mixer (IBBM), which has a receiver noise temperature of zero Kelvin. Based on the hot-spot model of a real HEB mixer, we model it as an IBBM in series with a passive resistance. An expression for the HEB receiver noise temperature, including optical input loss is then derived. We find that the predicted DSB receiver noise temperature agrees well with three sets of measured data. The result suggests that quantum noise and classical HEB noise contribute about equally at low terahertz frequencies while at higher terahertz frequencies quantum noise dominates.

Related papers

Quantum noise contribution to NbN hot electron bolometer receiver

E. Kollberg, P. Khosropanah, Wen Zhang +4 more

Abstract— Superconducting NbN hot electron bolometer (HEB) mixers are so far the most sensitive detectors for\nheterodyne spectroscopy in the frequency range between 1.5 THz and 5 THz. To reach the ultimate receiver noise\ntemperatures in the high end of the THz range (3-6 THz), it is crucial to understand their fundamental noise contribution\nfrom different origins. With increasing frequency, the classical output noise contribution should remain unchanged, but\nthe quantum noise contribution is expected to play an increasing role [1].\nThis paper reports the first dedicated experiment using a single NbN HEB mixer at a number of local oscillator\nfrequencies between 1.6 to 4.3 THz to address and quantify the contribution of the quantum noise to the receiver noise\ntemperature.\nWe used a spiral antenna coupled NbN HEB mixer with a bolometer size of 2 μm×0.2 μm. In order to minimize\nuncertainties in the corrections of the optical losses, we use a vacuum hot/cold load setup [2] to eliminate the air loss, and\nan uncoated elliptical Si lens. Although other components, a 3 μm Mylar beam splitter and a QMC heat filter, also\nintroduce frequency dependent optical losses, they can be accurately calibrated. Furthermore, to reduce uncertainties in\nthe data, we measure Y-factors responding to the hot/cold load by fixing the voltage, but varying the LO power [2]. As\nLO, we use a FIR gas laser.\nWe measure the Y-factor at the optimal point at different frequencies by only varying LO frequencies, but keeping\nthe rest exactly the same. We obtain DSB receiver noise temperatures, which are 842 K (at 1.6 THz), 845 K (1.9 THz), 974\nK (2.5 THz) and 1372 K (4.3 THz). After the correction for the losses of the QMC filter and the beam splitter, the noise\ndata show a linear increase with increasing frequency.\nUsing a quantum noise model [1] for HEB mixers and using a criterion for which the classical output noise must be\nconstant at different frequencies, we analyze the results and find the excess quantum noise factor β to be around 2 and\nthat 24 % of the total receiver noise temperature at 4.3 THz (at the input of the entire receiver) can be ascribed to\nquantum noise. Clearly the quantum noise has a small but measurable effect on the receiver noise temperature at this\nfrequency.\nWe are still analyzing different alternatives of interpretation for the mismatch loss between the bolometer and\nthe spiral antenna.\n[1] E. L. Kollberg and K. S. Yngvesson, “Quantum-noise theory for terahertz hot electron bolometer mixers,” IEEE Trans.\nMicrowave Theory and Techniques, 54, 2077, 2006.\n[2] P. Khosropanah, J.R. Gao, W.M. Laauwen, M. Hajenius and T.M. Klapwijk, “Low noise NbN hot-electron bolometer mixer\nat 4.3 THz,” Appl. Phys. Lett., 91, 221111, 2007.\n

•Jan 1, 2009•0 citations

Noise temperature distribution of superconducting hot electron bolometer mixers*

Kangmin Zhou, Wei Miao, Yue Geng +5 more

We report on the investigation of optimal bias region of a wide-band superconducting hot electron bolometer (HEB) mixer in terms of noise temperature performance for multi-pixel heterodyne receiver application in the 5-meter Dome A Terahertz Explorer (DATE5) telescope. By evaluating the double sideband (DSB) receiver noise temperature (T rec) across a wide frequency range from 0.2 THz to 1.34 THz and with a large number of bias points, a broad optimal bias region has been observed, illustrating a good bias applicability for multipixel application since the performance of the HEB mixer is uniquely determined by each bias point. The noise temperature of the HEB mixer has been analyzed by calibrating the noise contribution of all RF components, whose transmissions have been measured by a time-domain spectroscopy. The corrected noise temperature distribution shows a frequency independence relation. The dependence of the optimal bias region on the bath temperature of the HEB mixer has also been investigated, the bath temperature has limited effect on the lowest receiver noise temperature until 7 K, however the optimal bias region deteriorates obviously with increasing bath temperature.

Chinese Physics B•Mar 23, 2020•6 citations

Quantum noise in a terahertz hot electron bolometer mixer

Wen Zhang, P. Khosropanah, J. R. Gao +5 more

We have measured the noise temperature of a single, sensitive superconducting NbN hot electron bolometer (HEB) mixer in a frequency range from 1.6 to 5.3 THz, using a setup with all the key components in vacuum. By analyzing the measured receiver noise temperature using a quantum noise (QN) model for HEB mixers, we confirm the effect of QN. The QN is found to be responsible for about half of the receiver noise at the highest frequency in our measurements. The β-factor (the quantum efficiency of the HEB) obtained experimentally agrees reasonably well with the calculated value.

Applied Physics Letters•Mar 15, 2010•80 citations

Analysis of NbN Hot Electron Bolometer Receiver Noise Temperatures Above 2 THz With a Quantum Noise Model

P. Khosropanah, Wen Zhang, E. Kollberg +4 more

This paper summarizes our receiver noise temperature data of NbN HEB mixers obtained at a number of local oscillator frequencies between 1.9 to 4.3 THz in order to verify the role of quantum noise. The experimental data show that the receiver noise temperature increases roughly linearly with frequency. At 4.3 THz, we measured a receiver noise temperature of 1300 K, which is about 6 times (hf/kB) . The noise data at different frequencies are compared to a prediction of a noise model including the contribution of quantum noise and making use of a hot-spot model for mixing. We draw a preliminary conclusion that at 4.3 THz roughly 30% of the receiver noise temperature can be ascribed to the quantum noise. However, more dedicated measurements are required in order to further support the quantum noise model for HEB mixers.

IEEE Transactions on Applied Superconductivity•Jun 1, 2009•5 citations

Stability of heterodyne terahertz receivers

J. Kooi, J. J. A. Baselmans, Andrey M. Baryshev +6 more

In this paper we discuss the stability of heterodyne terahertz receivers based on small volume NbN phonon cooled hot electron bolometers (HEBs). The stability of these receivers can be broken down in two parts: the intrinsic stability of the HEB mixer and the stability of the local oscillator (LO) signal injection scheme. Measurements show that the HEB mixer stability is limited by gain fluctuations with a 1∕f spectral distribution. In a 60MHz noise bandwidth this results in an Allan variance stability time of ∼0.3s. Measurement of the spectroscopic Allan variance between two intermediate frequency (IF) channels results in a much longer Allan variance stability time, i.e., 3s between a 2.5 and a 4.7GHz channel, and even longer for more closely spaced channels. This implies that the HEB mixer 1∕f noise is strongly correlated across the IF band and that the correlation gets stronger the closer the IF channels are spaced. In the second part of the paper we discuss atmospheric and mechanical system stability requirements on the LO-mixer cavity path length. We calculate the mixer output noise fluctuations as a result of small perturbations of the LO-mixer standing wave, and find very stringent mechanical and atmospheric tolerance requirements for receivers operating at terahertz frequencies.

Journal of Applied Physics•Sep 15, 2006•39 citations

Terahertz Heterodyn Receiver with a hot-electron bolometer mixer

H.-W. Hübers, Alexej D. Semenov, Heiko Richter +6 more

During the past decade major advances have been made regarding low noise mixers for terahertz (THz) heterodyne receivers. State of the art hot-electron-bolometer (HEB) mixers have noise temperatures close to the quantum limit and require less than a µW power from the local oscillator (LO). The technology is now at a point where the performance of a practical receiver employing such mixer, rather than the figures of merit of the mixer itself, are of major concern. We have incorporated a phonon-cooled NbN HEB mixer in a 2.5 THz heterodyne receiver and investigated the performance of the receiver. This yields important information for the development of heterodyne receivers such as GREAT (German receiver for astronomy at THz frequencies aboard SOFIA) [1] and TELIS (Terahertz limb sounder), a balloon borne heterodyne receiver for atmospheric research [2]. Both are currently under development at DLR.

•Jan 1, 2002•0 citations
We have revised and considerably extended our paper on quantum noise at the 13 th ISSTT. In the present paper we first review general quantum mechanical limits on the sensitivity of heterodyne receivers. We introduce the ideal broad band mixer (IBBM), which has a receiver noise temperature of zero Kelvin. Based on the hot-spot model of a real HEB mixer, we model it as an IBBM in series with a passive resistance. An expression for the HEB receiver noise temperature, including optical input loss is then derived. We find that the predicted DSB receiver noise temperature agrees well with three sets of measured data. The result suggests that quantum noise and classical HEB noise contribute about equally at low terahertz frequencies while at higher terahertz frequencies quantum noise dominates.
Abstract— Superconducting NbN hot electron bolometer (HEB) mixers are so far the most sensitive detectors for\nheterodyne spectroscopy in the frequency range between 1.5 THz and 5 THz. To reach the ultimate receiver noise\ntemperatures in the high end of the THz range (3-6 THz), it is crucial to understand their fundamental noise contribution\nfrom different origins. With increasing frequency, the classical output noise contribution should remain unchanged, but\nthe quantum noise contribution is expected to play an increasing role [1].\nThis paper reports the first dedicated experiment using a single NbN HEB mixer at a number of local oscillator\nfrequencies between 1.6 to 4.3 THz to address and quantify the contribution of the quantum noise to the receiver noise\ntemperature.\nWe used a spiral antenna coupled NbN HEB mixer with a bolometer size of 2 μm×0.2 μm. In order to minimize\nuncertainties in the corrections of the optical losses, we use a vacuum hot/cold load setup [2] to eliminate the air loss, and\nan uncoated elliptical Si lens. Although other components, a 3 μm Mylar beam splitter and a QMC heat filter, also\nintroduce frequency dependent optical losses, they can be accurately calibrated. Furthermore, to reduce uncertainties in\nthe data, we measure Y-factors responding to the hot/cold load by fixing the voltage, but varying the LO power [2]. As\nLO, we use a FIR gas laser.\nWe measure the Y-factor at the optimal point at different frequencies by only varying LO frequencies, but keeping\nthe rest exactly the same. We obtain DSB receiver noise temperatures, which are 842 K (at 1.6 THz), 845 K (1.9 THz), 974\nK (2.5 THz) and 1372 K (4.3 THz). After the correction for the losses of the QMC filter and the beam splitter, the noise\ndata show a linear increase with increasing frequency.\nUsing a quantum noise model [1] for HEB mixers and using a criterion for which the classical output noise must be\nconstant at different frequencies, we analyze the results and find the excess quantum noise factor β to be around 2 and\nthat 24 % of the total receiver noise temperature at 4.3 THz (at the input of the entire receiver) can be ascribed to\nquantum noise. Clearly the quantum noise has a small but measurable effect on the receiver noise temperature at this\nfrequency.\nWe are still analyzing different alternatives of interpretation for the mismatch loss between the bolometer and\nthe spiral antenna.\n[1] E. L. Kollberg and K. S. Yngvesson, “Quantum-noise theory for terahertz hot electron bolometer mixers,” IEEE Trans.\nMicrowave Theory and Techniques, 54, 2077, 2006.\n[2] P. Khosropanah, J.R. Gao, W.M. Laauwen, M. Hajenius and T.M. Klapwijk, “Low noise NbN hot-electron bolometer mixer\nat 4.3 THz,” Appl. Phys. Lett., 91, 221111, 2007.\n
We report on the investigation of optimal bias region of a wide-band superconducting hot electron bolometer (HEB) mixer in terms of noise temperature performance for multi-pixel heterodyne receiver application in the 5-meter Dome A Terahertz Explorer (DATE5) telescope. By evaluating the double sideband (DSB) receiver noise temperature (T rec) across a wide frequency range from 0.2 THz to 1.34 THz and with a large number of bias points, a broad optimal bias region has been observed, illustrating a good bias applicability for multipixel application since the performance of the HEB mixer is uniquely determined by each bias point. The noise temperature of the HEB mixer has been analyzed by calibrating the noise contribution of all RF components, whose transmissions have been measured by a time-domain spectroscopy. The corrected noise temperature distribution shows a frequency independence relation. The dependence of the optimal bias region on the bath temperature of the HEB mixer has also been investigated, the bath temperature has limited effect on the lowest receiver noise temperature until 7 K, however the optimal bias region deteriorates obviously with increasing bath temperature.
We have measured the noise temperature of a single, sensitive superconducting NbN hot electron bolometer (HEB) mixer in a frequency range from 1.6 to 5.3 THz, using a setup with all the key components in vacuum. By analyzing the measured receiver noise temperature using a quantum noise (QN) model for HEB mixers, we confirm the effect of QN. The QN is found to be responsible for about half of the receiver noise at the highest frequency in our measurements. The β-factor (the quantum efficiency of the HEB) obtained experimentally agrees reasonably well with the calculated value.
This paper summarizes our receiver noise temperature data of NbN HEB mixers obtained at a number of local oscillator frequencies between 1.9 to 4.3 THz in order to verify the role of quantum noise. The experimental data show that the receiver noise temperature increases roughly linearly with frequency. At 4.3 THz, we measured a receiver noise temperature of 1300 K, which is about 6 times (hf/kB) . The noise data at different frequencies are compared to a prediction of a noise model including the contribution of quantum noise and making use of a hot-spot model for mixing. We draw a preliminary conclusion that at 4.3 THz roughly 30% of the receiver noise temperature can be ascribed to the quantum noise. However, more dedicated measurements are required in order to further support the quantum noise model for HEB mixers.
In this paper we discuss the stability of heterodyne terahertz receivers based on small volume NbN phonon cooled hot electron bolometers (HEBs). The stability of these receivers can be broken down in two parts: the intrinsic stability of the HEB mixer and the stability of the local oscillator (LO) signal injection scheme. Measurements show that the HEB mixer stability is limited by gain fluctuations with a 1∕f spectral distribution. In a 60MHz noise bandwidth this results in an Allan variance stability time of ∼0.3s. Measurement of the spectroscopic Allan variance between two intermediate frequency (IF) channels results in a much longer Allan variance stability time, i.e., 3s between a 2.5 and a 4.7GHz channel, and even longer for more closely spaced channels. This implies that the HEB mixer 1∕f noise is strongly correlated across the IF band and that the correlation gets stronger the closer the IF channels are spaced. In the second part of the paper we discuss atmospheric and mechanical system stability requirements on the LO-mixer cavity path length. We calculate the mixer output noise fluctuations as a result of small perturbations of the LO-mixer standing wave, and find very stringent mechanical and atmospheric tolerance requirements for receivers operating at terahertz frequencies.
During the past decade major advances have been made regarding low noise mixers for terahertz (THz) heterodyne receivers. State of the art hot-electron-bolometer (HEB) mixers have noise temperatures close to the quantum limit and require less than a µW power from the local oscillator (LO). The technology is now at a point where the performance of a practical receiver employing such mixer, rather than the figures of merit of the mixer itself, are of major concern. We have incorporated a phonon-cooled NbN HEB mixer in a 2.5 THz heterodyne receiver and investigated the performance of the receiver. This yields important information for the development of heterodyne receivers such as GREAT (German receiver for astronomy at THz frequencies aboard SOFIA) [1] and TELIS (Terahertz limb sounder), a balloon borne heterodyne receiver for atmospheric research [2]. Both are currently under development at DLR.