The improvement in the performance of an atomic line filter (ALF) under the action of a repump laser is reported in the current experimental work. We address the issue of repumping by including an additional laser coupling the 5S1/2(F=1)→5P3/2(F′′=2,1,0) hyperfine levels whereas the optical filter action is exhibited through a pump–probe laser-induced excited state absorption {5S1/2(F=2)→5P3/2(F′=3)→5D3/2(F′′=3)} of the Rb87 atom. It is found that the application of the repump mechanism considerably influences the characterizing parameters (i.e., transmittance and width) of the ALF. To optimize the performance of the ALF, it is required to carefully choose the detuning and intensity of the repump laser for a fixed set of pump–probe combination. For this purpose, the effect of systematic change in detuning and intensity of the repump laser on the ALF signal is studied in detail. For example, it is experimentally found that ALF considerably benefits (∼30%) in transmittance from selective repumping of atoms. It is to be noted that, unlike earlier reports, where the frequency scale of the filter is calibrated with Faby–Perot etalons of comparatively larger free spectral range, the marking is done here with the help of double resonance optical pumping (DROP) signals. The DROP signals, which originate from two-photon coupling within the 5S→5P→5D hyperfine domain, also act as an indicator of the existing “Radiation Trapping” process in the cascade medium. The current study may help in improving the performance of narrow-bandwidth ALF, which is useful for free space optical communication systems and laser spectroscopy.
Atomic line filters take advantage of the sharp spectral features offered by electronic transitions in free atoms. The basic idea is to convert a narrow atomic absorption profile into an equally narrow optical transmission filter by detecting the fluorescence radiation that is emitted after a photon has been absorbed. We developed the metastable thallium atomic line filter from the basic physical idea to a laboratory prototype in order to evaluate the usefulness of the technology for satellite borne backscatter LIDARs. Atomic thallium provides for an unsurpassed combination of features for this purpose. The input wavelength of the filter is 535 nm, which matches the frequency doubled Nd:BEL laser. The filter is an active device, it upconverts the 535 nm input into 378 nm output that is detected by a PMT. The experimental results were as expected concerning the characteristics directly related to atomic properties, i.e. the filter has only 10 ns response time, its optical bandwidth is 0.004 nm, and its acceptance angle is only limited by the device geometry. An optimized setup, with the size constraints of a space-borne system, displays a total quantum efficiency of 2%, i.e. from input photons to detected output photons. This constitutes a remarkable and unsurpassed value for atomic line filters but is too low for the application in mind. (A ground-based, scaled-up version of our prototype would reach about 10% quantum efficiency). In addition, the 500 degree(s)C operating temperature of the vapor cell requires sophisticated thermal layout and thermal shielding, which means a lot of added mass and volume. In summary, we found that atomic line filters can be built that offer characteristics not found with other technologies, but their applicability for space borne systems is questionable.
Excitation transfer between the
62P21 and
62P23 resonance states in cesium, induced by Cs-
N2 and Cs-
H2 collisions, was observed in the first experiment of its kind, in which techniques of sensitized fluorescence are used to investigate collisional mixing between resonance states of alkali atoms in mixtures with molecular gases. The cesium-vapor-gas system, in which the cesium vapor pressure was low enough to avoid radiation trapping, was irradiated with a single component of the resonance doublet. The fluorescent light, which contained both components of the doublet, was monitored at right angles to the direction of excitation. Measurements of relative intensities of the fluorescent components yielded the following cross sections for excitation transfer and for quenching of resonance radiation. For Cs-
N2 collisions: ${Q}_{12}(^{2}P_{\frac{1}{2}}\ensuremath{\rightarrow}^{2}P_{\frac{3}{2}})=3.6$
A˚2, ${Q}_{21}(^{2}P_{\frac{1}{2}}\ensuremath{\leftarrow}^{2}P_{\frac{3}{2}})=16.2$
A˚2, ${Q}_{10}(^{2}S_{\frac{1}{2}}\ensuremath{\leftarrow}^{2}P_{\frac{1}{2}})=55.2$
A˚2, ${Q}_{20}(^{2}S_{\frac{1}{2}}\ensuremath{\leftarrow}^{2}P_{\frac{3}{2}})=63.5$
A˚2. For Cs-
H2 collisions:
Q12=6.7 A˚2,
Q21=29.6 A˚2,
Q10=11.7 A˚2,
Q20=6.7 A˚2. The large sizes of the excitation-transfer cross sections, which are comparable to the corresponding Cs-Cs cross sections, are attributed to resonances with transitions in the molecules.
We present a new atomic line filter concept for the detection of frequency-doubled Nd:BEL laser radiation. Advantage is taken of the thallium 6(2)P(3/2) metastable energy level whose large lifetime can be preserved even in small vapor cells. The filter is pumped intermittently by a low-power spectral lamp and thereby combines the benefits of active and passive operation. Analysis of a proposed final design shows that simple engineering solutions exist, and excellent filter properties can be deduced. We have experimentally demonstrated the new operating principle in a preliminary setup.