Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Springer eBooks

Single-Ion Optical Frequency Standards and Measurement of their Absolute Optical Frequency

Alan A. Madej, J. E. Bernard

Published Jul 29, 2007• 25 citations
Publisher
DOI
10.1007/3-540-44991-4_7

Related papers

Progress Toward an Optical Frequency Standard Based on a Single Indium Ion

Y. H. Wang, T. Liu, Alois Stejskal +7 more

We report on the current status of the optical frequency standard based on a single 115In+ ion. A single Indium ion is being trapped in a Paul-Strauble type trap and cooled in combination of Doppler cooling and sideband cooling to its lowest vibrational states. To interrogate the1S0-3P0clock transition with high accuracy we demonstrate a Hz-level laser system resonant to this transition. With the current setup we are able to achieve a measured linewidth of the clock transition of 260 Hz. The statistical uncertainty of the absolute frequency measurement is 3×10-13, limited mainly by our reference frequency standard.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jun 1, 2006•6 citations

3 Optical frequency standards based on trapped single ions

Kelin Gao

De Gruyter eBooks•Jun 9, 2022•0 citations

Progress towards an optical frequency standard based on ion traps

Richard Claude Thompson, G. P. Barwood, Patrick Robert Gill

Applied Physics B•May 1, 1988•22 citations

Electric Quadrupole Shift Cancellation in Single-Ion Optical Frequency Standards

P. Dubé, Alan A. Madej, J. E. Bernard +3 more

The electric quadrupole shift is presently the most significant source of uncertainty on the systematic shifts for several single-ion optical frequency standards. We present a simple method for cancelling this shift based on measurements of the Zeeman spectrum of the clock transition. This method is easy to implement and yields very high cancellation levels. A fractional uncertainty of 5 x 10(-18) for the canceled quadrupole shift is estimated for a measurement of the absolute frequency of the 5s (2)S(1/2)-4d (2)D(5/2) clock transition of 88Sr+.

Physical Review Letters•Jul 12, 2005•152 citations

Absolute frequency measurement of a $^{176}$Lu$^+\,(^{3}\mathrm{D}_1)$ standard against the NRC-FCs2 fountain with $2.6\times10^{-16}$ uncertainty

K. J. Arnold, Bin Jian, Zhao Zhang +6 more

We report an improved absolute frequency measurement of the $^{176}$Lu$^+\,(^{3}\mathrm{D}_1)$ optical frequency standard, evaluated via a remote link to the NRC-FCs2 caesium fountain primary frequency standard. Operating a single ion clock with 94.2% uptime over 10 days, and using an ambiguity-resolved precise point positioning (PPP-AR) link over the Global Positioning System, we determine an absolute frequency of $353\,638\,794\,073\,800.332(91)\,$Hz at a fractional uncertainty of $2.6 \times 10^{-16}$. This agrees with our previous result, which underpins the Comité international des poids et mesures recommended frequency value, and reduces the uncertainty by a factor of 3.6.

physics.atom-phCross-listedarXiv:2607.07044•Jul 9, 2026

Single Ion Optical Frequency Standard | NIST

Jonas Bergquist, Wayne M. Itano, David J. Wineland +3 more

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 28, 1991•0 citations
We report on the current status of the optical frequency standard based on a single 115In+ ion. A single Indium ion is being trapped in a Paul-Strauble type trap and cooled in combination of Doppler cooling and sideband cooling to its lowest vibrational states. To interrogate the1S0-3P0clock transition with high accuracy we demonstrate a Hz-level laser system resonant to this transition. With the current setup we are able to achieve a measured linewidth of the clock transition of 260 Hz. The statistical uncertainty of the absolute frequency measurement is 3×10-13, limited mainly by our reference frequency standard.
The electric quadrupole shift is presently the most significant source of uncertainty on the systematic shifts for several single-ion optical frequency standards. We present a simple method for cancelling this shift based on measurements of the Zeeman spectrum of the clock transition. This method is easy to implement and yields very high cancellation levels. A fractional uncertainty of 5 x 10(-18) for the canceled quadrupole shift is estimated for a measurement of the absolute frequency of the 5s (2)S(1/2)-4d (2)D(5/2) clock transition of 88Sr+.
Absolute frequency measurement of a 176^{176}176Lu+ (3D1)^+\,(^{3}\mathrm{D}_1)+(3D1​) standard against the NRC-FCs2 fountain with 2.6×10−162.6\times10^{-16}2.6×10−16 uncertainty
We report an improved absolute frequency measurement of the 176^{176}176Lu+ (3D1)^+\,(^{3}\mathrm{D}_1)+(3D1​) optical frequency standard, evaluated via a remote link to the NRC-FCs2 caesium fountain primary frequency standard. Operating a single ion clock with 94.2% uptime over 10 days, and using an ambiguity-resolved precise point positioning (PPP-AR) link over the Global Positioning System, we determine an absolute frequency of 353 638 794 073 800.332(91) 353\,638\,794\,073\,800.332(91)\,353638794073800.332(91)Hz at a fractional uncertainty of 2.6×10−162.6 \times 10^{-16}2.6×10−16. This agrees with our previous result, which underpins the Comité international des poids et mesures recommended frequency value, and reduces the uncertainty by a factor of 3.6.