Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Quasiparticle poisoning induced by a biased SET electrometer

Jos 'e Aumentado, Ofer Naaman

Published Mar 25, 2005• 0 citations
OpenAlex

Related papers

Quasiparticle poisoning in charge qubits

Jaan Männik

•Oct 1, 2003•0 citations

Quasiparticle Poisoning in a Cooper-Pair Box

B. S. Palmer, Carlos Sánchez, Akshay K. Naik +4 more

Bulletin of the American Physical Society•Mar 14, 2006•0 citations

Real-time observation of quasiparticle poisoning in a single cooper pair transistor

Ofer Naaman, Jos 'e Aumentado

Bulletin of the American Physical Society•Mar 25, 2005•0 citations

Diagnostics and abatement of quasiparticle poisoning in superconducting quantum circuits

Francesco Valenti

•Jan 1, 2021•0 citations

Quasiparticle Poisoning in a Cooper Pair Box caused by a measuring SET

Carlos Sánchez‐Somolinos, B. S. Palmer, M. A. Manheimer +1 more

box in the presence of quasiparticle poisoning. The model uses a master equation approach to flnd the probabilities for the box to be in the even or odd state. The transition rates between the two states are calculated assuming a flxed number of non-equilibrium quasiparticles in the leads and island of the box. We fabricated Al/AlOx/Al devices with a Cooper pair box capacitively coupled to an SET and measured the charge on the box for SET bias currents ranging from about 1 pA to 1 nA. We flnd good agreement between the theory and measurements in the temperature range from 60 mK to 300 mK. For large SET bias the poisoning in the Cooper pair box increases and the charge staircase develops additional features. Our model is capable of qualitatively reproducing the features induced by the measuring SET.

Bulletin of the American Physical Society•Mar 16, 2006•0 citations

Effect of Measurement on the Periodicity of the Coulomb Staircase of a Superconducting Box

Jaan Männik, James E. Lukens

We report on the effect of the backaction of a single Cooper pair transistor electrometer ($\mathbf{E}$) on the charge state of a superconducting box ($\mathbf{B}$). The charge is $e$ periodic in the gate bias of $\mathbf{B}$ when $\mathbf{E}$ is operated near voltages $2\ensuremath{\Delta}/e$ or $4\ensuremath{\Delta}/e$. We show that this is due to quasiparticle poisoning of $\mathbf{B}$ at a rate proportional to the number of quasiparticle tunneling events in $\mathbf{E}$ per second. We are able to eliminate this backaction and recover $2e$-charge periodicity using a new measurement method based on switching-current modulation of $\mathbf{E}$.

arXiv:cond-mat/0305190•Physical Review Letters•Feb 5, 2004•46 citations
box in the presence of quasiparticle poisoning. The model uses a master equation approach to flnd the probabilities for the box to be in the even or odd state. The transition rates between the two states are calculated assuming a flxed number of non-equilibrium quasiparticles in the leads and island of the box. We fabricated Al/AlOx/Al devices with a Cooper pair box capacitively coupled to an SET and measured the charge on the box for SET bias currents ranging from about 1 pA to 1 nA. We flnd good agreement between the theory and measurements in the temperature range from 60 mK to 300 mK. For large SET bias the poisoning in the Cooper pair box increases and the charge staircase develops additional features. Our model is capable of qualitatively reproducing the features induced by the measuring SET.
We report on the effect of the backaction of a single Cooper pair transistor electrometer (E\mathbf{E}E) on the charge state of a superconducting box (B\mathbf{B}B). The charge is eee periodic in the gate bias of B\mathbf{B}B when E\mathbf{E}E is operated near voltages $2\ensuremath{\Delta}/e$ or $4\ensuremath{\Delta}/e$. We show that this is due to quasiparticle poisoning of B\mathbf{B}B at a rate proportional to the number of quasiparticle tunneling events in E\mathbf{E}E per second. We are able to eliminate this backaction and recover 2e2e2e-charge periodicity using a new measurement method based on switching-current modulation of E\mathbf{E}E.