Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

APS March Meeting Abstracts

Voltage-biased superconducting bolometers for infrared and mm-Waves

Jan M. Gildemeister, Adrian Tae-Jin Lee, Shih-Fu Lee, P. L. Richards

Published Mar 1, 1998• 8 citations
OpenAlex

Related papers

Voltage-Biased Superconducting TES Bolometers for the Far-Infrared to Millimeter Wavelength Range

Adrian Tae-Jin Lee, Sherry Cho, Jan M. Gildemeister +10 more

•Jan 1, 2002•1 citation

Development of SQUID Amplifier and AC-biased Bolometer for Detection of Sub-mm Radiation

Jari S Penttilä, Antti Virtanen, M. R. Nevala +7 more

•Jan 1, 2004•0 citations

Study of Mid-infrared Superconducting Hot Electron Bolometer Mixers

Akira Kawakami, Hisashi Shimakage, Junsei Horikawa +4 more

IEICE Technical Report; IEICE Tech. Rep.•Jan 12, 2017•0 citations

Evaluation of Mid Infrared Superconducting Hot Electron Bolometer Mixers

Akira Kawakami, Hisashi Shimakage, Junsei Horikawa +2 more

The Japan Society of Applied Physics•Feb 8, 2018•0 citations

Evaluation of Mid Infrared Superconducting Hot Electron Bolometer Mixer

Akira Kawakami, Hisashi Shimakage, Junsei Horikawa +2 more

IEICE Technical Report; IEICE Tech. Rep.•Apr 13, 2018•1 citation

A fully lithographed voltage-biased superconducting spiderweb bolometer

Jan M. Gildemeister, Adrian Tae-Jin Lee, P. L. Richards

We describe the fabrication and characterization of superconducting transition-edge bolometers for astrophysical applications at far-infrared and mm wavelengths. The sensor is voltage biased and the current is measured with a superconducting quantum interference ammeter. Strong negative electrothermal feedback keeps the sensor temperature nearly constant, reduces the response time significantly, and improves linearity. It also makes the responsivity relatively insensitive to changes in optical background loading and refrigerator temperature. The bolometers are made using standard microlithographic techniques suitable for fabrication of large scale arrays. Detailed measurements of optical response are presented for a range of bias conditions and are compared with theory. Measured noise spectra are shown and a model for the noise is presented.

Applied Physics Letters•Feb 8, 1999•89 citations
We describe the fabrication and characterization of superconducting transition-edge bolometers for astrophysical applications at far-infrared and mm wavelengths. The sensor is voltage biased and the current is measured with a superconducting quantum interference ammeter. Strong negative electrothermal feedback keeps the sensor temperature nearly constant, reduces the response time significantly, and improves linearity. It also makes the responsivity relatively insensitive to changes in optical background loading and refrigerator temperature. The bolometers are made using standard microlithographic techniques suitable for fabrication of large scale arrays. Detailed measurements of optical response are presented for a range of bias conditions and are compared with theory. Measured noise spectra are shown and a model for the noise is presented.