Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

European Quantum Electronics Conference (EQEC)

Experiments with cold triplet helium atoms in a trap

Paul J. J. Tol, Norbert Herschbach, W. Hogervorst, W. Vassen

Published Aug 24, 2005• 0 citations
Publisher
DOI
10.1109/eqec.1998.714697

Related papers

A Magnetostatic Trap for Triplet Helium

Paul J. J. Tol, Norbert Herschbach, W. Hogervorst +1 more

•Jan 1, 1999•0 citations

Evaporative cooling in a magnetostatic trap of triplet helium

W. Vassen, Norbert Herschbach, Paul J. J. Tol +1 more

AIP conference proceedings•Jan 1, 2000•0 citations

Metastable-Helium-4 source for cold atom experiments

Mateusz Kotyrba

•Jan 1, 2010•0 citations

Trapping fermionic and bosonic helium atoms

R. J. W. Stas

This thesis presents experimental and theoretical work performed at the Laser Centre of the Vrije Universiteit in Amsterdam to study laser-cooled metastable triplet helium atoms. Samples containing about 3x10^8 helium atoms-either fermionic helium-3 atoms, bosonic helium-4 atoms or mixtures thereof-are cooled to a temperature around 1 mK and form the starting point of the presented studies. The studies include an investigation of cold ionizing collisions in the absence of resonant light, an investigation of magneto-optical trapping with ultraviolet light, a feasibility study of an atomic fountain clock based on metastable helium-3 atoms and the first demonstration of magneto-optical trapping of an isotopic mixture of metastable helium atoms.

•Jun 1, 2005•1 citation

a Trap for Metastable Helium Atoms

Wilbert Rooijakkers, W. Hogervorst, W. Vassen

European Quantum Electronics Conference (EQEC)•Jan 1, 1996•0 citations

Large numbers of cold metastable helium atoms in a magneto-optical trap

Paul J. J. Tol, Norbert Herschbach, Eric A. Hessels +2 more

We report loading of $1.5\ifmmode\times\else\texttimes\fi{}{10}^{9}$ metastable triplet helium atoms in a large magneto-optical trap, using far-red-detuned laser beams. We fully characterized this trap by measuring trap losses and absorption of a probe beam. From the highly nonexponential trap decay we derive Penning ionization loss rate coefficients for two detunings: $5.3(9)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}9}{\mathrm{cm}}^{3}/\mathrm{s}$ at $\ensuremath{-}35\mathrm{MHz}$ and $3.7(6)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}9}{\mathrm{cm}}^{3}/\mathrm{s}$ at $\ensuremath{-}44\mathrm{MHz}.$ Also, we find that the loss rate is maximum at $\ensuremath{-}5\mathrm{MHz}$ detuning, where the rate is $1.3(3)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}{\mathrm{cm}}^{3}/\mathrm{s},$ much larger than recent theoretical and experimental values. In the absence of light the $S\ensuremath{-}S$ ionization rate constant is measured to be $1.3(2)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}10}{\mathrm{cm}}^{3}/\mathrm{s}.$

Physical Review A•Aug 1, 1999•54 citations
This thesis presents experimental and theoretical work performed at the Laser Centre of the Vrije Universiteit in Amsterdam to study laser-cooled metastable triplet helium atoms. Samples containing about 3x10^8 helium atoms-either fermionic helium-3 atoms, bosonic helium-4 atoms or mixtures thereof-are cooled to a temperature around 1 mK and form the starting point of the presented studies. The studies include an investigation of cold ionizing collisions in the absence of resonant light, an investigation of magneto-optical trapping with ultraviolet light, a feasibility study of an atomic fountain clock based on metastable helium-3 atoms and the first demonstration of magneto-optical trapping of an isotopic mixture of metastable helium atoms.
We report loading of $1.5\ifmmode\times\else\texttimes\fi{}{10}^{9}$ metastable triplet helium atoms in a large magneto-optical trap, using far-red-detuned laser beams. We fully characterized this trap by measuring trap losses and absorption of a probe beam. From the highly nonexponential trap decay we derive Penning ionization loss rate coefficients for two detunings: $5.3(9)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}9}{\mathrm{cm}}^{3}/\mathrm{s}$ at $\ensuremath{-}35\mathrm{MHz}$ and $3.7(6)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}9}{\mathrm{cm}}^{3}/\mathrm{s}$ at $\ensuremath{-}44\mathrm{MHz}.$ Also, we find that the loss rate is maximum at $\ensuremath{-}5\mathrm{MHz}$ detuning, where the rate is $1.3(3)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}{\mathrm{cm}}^{3}/\mathrm{s},$ much larger than recent theoretical and experimental values. In the absence of light the $S\ensuremath{-}S$ ionization rate constant is measured to be $1.3(2)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}10}{\mathrm{cm}}^{3}/\mathrm{s}.$