Wiley eBooks

Single‐Photon Metrology and Quantum Radiometry

Ernst Otto Göbel, U. Siegner

Published Jun 12, 2015• 2 citations
Publisher

Abstract

Radiometric quantities, like the (spectral) radiative power, in principle can be based on counting single photons. Hence, by considering the luminosity function of the human eye response also photometric quantities, like luminous flux, could be traced back to counting single photons. In this chapter we introduce single-photon sources emitting non classical light. They are characterized by the normalized second-order correlation function with values smaller than one for short delay times. We present color centers in diamond and semiconductor quantum dots as examples. We then discuss photon detectors and pay particular attention to photon-number-resolving detectors. As example, we describe the action and properties of superconducting transition-edge sensors (TES). Finally, we pay attention to the challenge to bridge the power from the single-photon level to practical power values by calibrating single-photon detectors, e.g. by using synchrotron radiation.

DOI
10.1002/9783527680887.ch9

Related papers

Single photon sources for quantum radiometry: a brief review about the current state-of-the-art

S. Kück, Marco López, Helmuth Hofer +17 more

Abstract Single-photon sources have a variety of applications. One of these is quantum radiometry, which is reported on in this paper in the form of an overview, specifically of the current state of the art in the application of deterministic single photon sources to the calibration of single photon detectors. To optimize single-photon sources for this purpose, extensive research is currently carried out at the European National Metrology Institutes (NMIs), in collaboration with partners from universities. Single-photon sources of different types are currently under investigation, including sources based on defect centres in (nano-)diamonds, on molecules and on semiconductor quantum dots. We will present, summarise, and compare the current results obtained at European NMIs for single-photon sources in terms of photon flux, single-photon purity, and spectral power distribution as well as the results of single-photon detector calibrations carried out with this type of light sources.

Applied Physics B•Jan 23, 2022•13 citations

Quantum metrology of solid-state single-photon sources using photon-number-resolving detectors

Martin von Helversen, Jonas Böhm, Marco Schmidt +7 more

Quantum-light sources based on semiconductor quantum dots (QDs) are promising candidates for many applications in quantum photonics and quantum communication. Important emission characteristics of such emitters, namely the single-photon purity and photon indistinguishability, are usually assessed via time-correlated measurements using standard 'click' detectors in Hanbury Brown and Twiss or Hong-Ou-Mandel (HOM-) type configurations. In this work, we employ a state-of-the-art photon-number-resolving (PNR) detection system based on superconducting transition-edge sensors (TESs) to directly access the photon-number distribution of deterministically fabricated solid-state single-photon sources. Offering quantum efficiencies close to unity and high energy resolution, our TES-based two-channel detector system allows us to analyse the quantum optical properties of a QD-based non-classical light source. In particular, it enables the direct observation of the two-particle Fock-state resulting from interference of quantum mechanically indistinguishable photons in HOM-experiments. Additionally, comparative measurements reveal excellent quantitative agreement of the photon-indistinguishabilities obtained with PNR ((90 ± 7)%) and standard click ((90 ± 5)%) detectors. Our work thus demonstrates that TES-based detectors are perfectly suitable for the quantum metrology of non-classical light sources and higlights appealing prospects for the efficient implementation of quantum information tasks based on multi-photon states.

New Journal of Physics•Feb 11, 2019•58 citations

Metrological characterization of a commercial single-photon source with high photon flux emission

Hristina Georgieva, Petr Stepanov, Leonora Sewidan +3 more

Abstract We present a comprehensive metrological characterization of a commercial single-photon source with high photon flux emission for use in radiometry. The source is based on an InGaAs quantum dot in a micropillar. A comparative analysis of two excitation schemes—phonon-assisted excitation and two-photon excitation—explores differences in excitation power dependence, temporal stability and single-photon purity. The commercial source exhibits excellent properties for the field of quantum radiometry, achieving simultaneously a photon flux of (17.19 ± 0.09) million photons/s for a pulse repetition rate of 79.4 MHz, and a single-photon purity of 98%. Its optical power of (3.68 ± 0.02) pW is directly determined with a traceably calibrated low-noise photodiode. The ability to directly compare the photocurrent in a low-noise photodiode with the count rate at a single-photon avalanche detector allows for a seamless transition between the classical and quantum realizations of optical power. Therefore, we were able to build another bridge between classical and quantum radiometry by using a deterministic single-photon source.

Metrologia•Jul 10, 2024•3 citations

Single-photon quantum metrology (Conference Presentation)

Thomas Gerrits

We will present our current efforts on single photon quantum metrology using high-efficiency superconducting detectors and high-efficiency single-photon sources based on spontaneous parametric downconversion. Optical power measurements based on single photon counting could establish a quantum standard for optical power calibration in the future. At NIST we are pursuing the development of single photon sources and single photon detectors for metrology, quantum and classical applications. As part of these efforts, we are pursuing the establishment of a measurement service for the calibration of single photon detectors. We present how our calibration is tied to the calibration of our transfer standard optical fiber power meters. Using the beamsplitter method, we have implemented a fiber-coupled and free-space measurement system. Also, we have developed testbeds and measurement protocols for the characterization of single photon sources and single photon detectors. We will review several methods, which allow for the characterization of the spatial and spectral degree of freedom in spontaneous parametric downconversion.

•Mar 5, 2019•0 citations

Single photon sources for absolute radiometry – A review about the current state of the art

S. Kück

In this presentation a review about the current state of the art concerning the application of deterministic single photon sources for absolute radiometry, i.e. the calibration of single photon detectors, is given. At the Physikalisch-Technische Bundesanstalt, the German national Metrology institute, an extensive research is carried out to optimize single photon sources for this purpose. Different single photon sources are currently under investigation, these are sources based on defect centres in (nano-)diamonds, on molecules and on semiconductor quantum dots.

Measurement Sensors•Oct 19, 2021•9 citations

Extending single-photon optimized superconducting transition edge sensors beyond the single-photon counting regime

Thomas Gerrits, Brice Calkins, Nathan A. Tomlin +4 more

Typically, transition edge sensors resolve photon number of up to 10 or 20 photons, depending on the wavelength and TES design. We extend that dynamic range up to 1000 photons, while maintaining sub-shot noise detection process uncertainty of the number of detected photons and beyond that show a monotonic response up to ≈ 6 · 10(6) photons in a single light pulse. This mode of operation, which heats the sensor far beyond its transition edge into the normal conductive regime, offers a technique for connecting single-photon-counting measurements to radiant-power measurements at picowatt levels. Connecting these two usually incompatible operating regimes in a single detector offers significant potential for directly tying photon counting measurements to conventional cryogenic radiometric standards. In addition, our measurements highlight the advantages of a photon-number state source over a coherent pulse source as a tool for characterizing such a detector.

Optics Express•Oct 2, 2012•55 citations
Radiometric quantities, like the (spectral) radiative power, in principle can be based on counting single photons. Hence, by considering the luminosity function of the human eye response also photometric quantities, like luminous flux, could be traced back to counting single photons. In this chapter we introduce single-photon sources emitting non classical light. They are characterized by the normalized second-order correlation function with values smaller than one for short delay times. We present color centers in diamond and semiconductor quantum dots as examples. We then discuss photon detectors and pay particular attention to photon-number-resolving detectors. As example, we describe the action and properties of superconducting transition-edge sensors (TES). Finally, we pay attention to the challenge to bridge the power from the single-photon level to practical power values by calibrating single-photon detectors, e.g. by using synchrotron radiation.
Abstract Single-photon sources have a variety of applications. One of these is quantum radiometry, which is reported on in this paper in the form of an overview, specifically of the current state of the art in the application of deterministic single photon sources to the calibration of single photon detectors. To optimize single-photon sources for this purpose, extensive research is currently carried out at the European National Metrology Institutes (NMIs), in collaboration with partners from universities. Single-photon sources of different types are currently under investigation, including sources based on defect centres in (nano-)diamonds, on molecules and on semiconductor quantum dots. We will present, summarise, and compare the current results obtained at European NMIs for single-photon sources in terms of photon flux, single-photon purity, and spectral power distribution as well as the results of single-photon detector calibrations carried out with this type of light sources.
Quantum-light sources based on semiconductor quantum dots (QDs) are promising candidates for many applications in quantum photonics and quantum communication. Important emission characteristics of such emitters, namely the single-photon purity and photon indistinguishability, are usually assessed via time-correlated measurements using standard 'click' detectors in Hanbury Brown and Twiss or Hong-Ou-Mandel (HOM-) type configurations. In this work, we employ a state-of-the-art photon-number-resolving (PNR) detection system based on superconducting transition-edge sensors (TESs) to directly access the photon-number distribution of deterministically fabricated solid-state single-photon sources. Offering quantum efficiencies close to unity and high energy resolution, our TES-based two-channel detector system allows us to analyse the quantum optical properties of a QD-based non-classical light source. In particular, it enables the direct observation of the two-particle Fock-state resulting from interference of quantum mechanically indistinguishable photons in HOM-experiments. Additionally, comparative measurements reveal excellent quantitative agreement of the photon-indistinguishabilities obtained with PNR ((90 ± 7)%) and standard click ((90 ± 5)%) detectors. Our work thus demonstrates that TES-based detectors are perfectly suitable for the quantum metrology of non-classical light sources and higlights appealing prospects for the efficient implementation of quantum information tasks based on multi-photon states.
Abstract We present a comprehensive metrological characterization of a commercial single-photon source with high photon flux emission for use in radiometry. The source is based on an InGaAs quantum dot in a micropillar. A comparative analysis of two excitation schemes—phonon-assisted excitation and two-photon excitation—explores differences in excitation power dependence, temporal stability and single-photon purity. The commercial source exhibits excellent properties for the field of quantum radiometry, achieving simultaneously a photon flux of (17.19 ± 0.09) million photons/s for a pulse repetition rate of 79.4 MHz, and a single-photon purity of 98%. Its optical power of (3.68 ± 0.02) pW is directly determined with a traceably calibrated low-noise photodiode. The ability to directly compare the photocurrent in a low-noise photodiode with the count rate at a single-photon avalanche detector allows for a seamless transition between the classical and quantum realizations of optical power. Therefore, we were able to build another bridge between classical and quantum radiometry by using a deterministic single-photon source.
We will present our current efforts on single photon quantum metrology using high-efficiency superconducting detectors and high-efficiency single-photon sources based on spontaneous parametric downconversion. Optical power measurements based on single photon counting could establish a quantum standard for optical power calibration in the future. At NIST we are pursuing the development of single photon sources and single photon detectors for metrology, quantum and classical applications. As part of these efforts, we are pursuing the establishment of a measurement service for the calibration of single photon detectors. We present how our calibration is tied to the calibration of our transfer standard optical fiber power meters. Using the beamsplitter method, we have implemented a fiber-coupled and free-space measurement system. Also, we have developed testbeds and measurement protocols for the characterization of single photon sources and single photon detectors. We will review several methods, which allow for the characterization of the spatial and spectral degree of freedom in spontaneous parametric downconversion.
In this presentation a review about the current state of the art concerning the application of deterministic single photon sources for absolute radiometry, i.e. the calibration of single photon detectors, is given. At the Physikalisch-Technische Bundesanstalt, the German national Metrology institute, an extensive research is carried out to optimize single photon sources for this purpose. Different single photon sources are currently under investigation, these are sources based on defect centres in (nano-)diamonds, on molecules and on semiconductor quantum dots.
Typically, transition edge sensors resolve photon number of up to 10 or 20 photons, depending on the wavelength and TES design. We extend that dynamic range up to 1000 photons, while maintaining sub-shot noise detection process uncertainty of the number of detected photons and beyond that show a monotonic response up to ≈ 6 · 10(6) photons in a single light pulse. This mode of operation, which heats the sensor far beyond its transition edge into the normal conductive regime, offers a technique for connecting single-photon-counting measurements to radiant-power measurements at picowatt levels. Connecting these two usually incompatible operating regimes in a single detector offers significant potential for directly tying photon counting measurements to conventional cryogenic radiometric standards. In addition, our measurements highlight the advantages of a photon-number state source over a coherent pulse source as a tool for characterizing such a detector.