Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Low Temperature Physics

Dependence on the pump frequency of the sensitivity of the rf SQUID

Reino I. Ker�nen, Juhani Kurkij�rvi

Published Nov 1, 1986• 3 citations
Publisher
DOI
10.1007/bf00683977

Related papers

Investigation on readout coil for the improvement of rf-SQUID sensitivity

祐治 宮戸, 紳太郎 東口, 永純 安達 +1 more

IEICE technical report. Speech•Jan 14, 2016•0 citations

Double rf-SQUIDs Operating in a Non-Adiabatic Regime: A Dream Comes True?

Boris Chesca

At a time when the supremacy of SQUIDs as the most sensitive magnetometers is being challenged by the recent progress of optically pumped atomic magnetometers operating at room temperature, looking into new opportunities to further improve SQUIDs sensitivity would probably be most welcomed by the SQUID community. By far the most promising such opportunity is to operate a double (D) rf SQUID (an rf-SQUID in which a dc-SQUID is used instead of a single Josephson junction) in a non-adiabatic regime at frequencies of about a few GHz. At these relatively high frequencies required to assure an ultra-high SQUID sensitivity the SQUID-design complexity and the cost of the electronics involved (current generator and SQUID amplifier) are still kept at reasonable levels. The advantages of using this concept, as presented in my contribution in more detail now, are overwhelming. Ironically, although this idea in its preliminary shape has been around for some time now [1], the opportunity has never been explored experimentally! I am just wondering what else needs to be done to get this message across the SQUID community and have this concept finally tested experimentally?

Physics Procedia•Jan 1, 2012•2 citations

RF-SQUID CHARACTERISTICS IN A HIGH-FREQUENCY LIMIT

Oleg V. Snigirev

•Jan 1, 1981•0 citations

SIGNAL AND NOISE CHARACTERISTICS OF RF-SQUIDS

V. I. Shnyrkov, Georgy M. Tsoi

WORLD SCIENTIFIC eBooks•Jun 1, 1992•6 citations

Thermal magnetic noise in rf SQUIDS coupled to ferromagnetic cores

Stefano Vitale, Giovanni Andrea Prodi, MASSIMO CERDONIO

We present a simple model for the thermal magnetic noise in a rf SQUID coupled to a ferromagnetic core via a superconducting dc flux transformer. We show that, under conditions that are almost always fulfilled in practice, the coupling to the core can be described in terms of a SQUID frequency-dependent complex inductance Ls (ω). This inductance reduces to an ordinary, frequency-independent real value above a roll-off frequency ωc . To this inductance, a Nyquist flux noise generator is associated, with spectral density S′2φi(ω) =−4kBT Im[Ls(ω)]/ ω, where kB is the Boltzmann constant, T the temperature, and Im[Ls (ω)] the imaginary part of Ls (ω). If ωc ≪ωrf , with ωrf the frequency of the rf pump, then the response of the SQUID to low-frequency signals is not modified by the coupling to the core, while the above Nyquist noise acts as an additive input noise. We experimentally demonstrate the model for a SQUID coupled to a toroidal core.

Journal of Applied Physics•Mar 1, 1989•28 citations

Ultrahigh frequency thin film rf-SQUID magnetometer with a cryogenic preamplifier employing a high-electron-mobility transistor

Antonella Cavalleri, MASSIMO CERDONIO, Giorgio Fontana +5 more

Ultrahigh frequency rf-SQUID magnetometer employing a cryogenic preamplifier and a commercially available thin film rf-SQUID sensor have been designed, manufactured, and tested. The system has been operated at 316 MHz, which is the maximum pump frequency accepted by the thin film sensor. The cryogenic preamplifier has been built around a microwave high-electron-mobility transistor which was made unconditionally stable at ultrahigh frequency band by means of an appropriate circuit design, namely, a cascode configuration. The total flux noise of the magnetometer has been found to be 8.4 × 10−6Φ0/√Hz at 4.2 K and 5.8× 10−6Φ0/√Hz at 1.4 K. The temperature dependence of the fractional step rise α of the current-voltage rf characteristic has been measured to be proportional to the 2/3 power of the SQUID sensor temperature. The noise performance of the system at 4.2 K has been limited by the intrinsic SQUID noise only, in good agreement with theoretical predictions.

Review of Scientific Instruments•Nov 1, 1992•4 citations
At a time when the supremacy of SQUIDs as the most sensitive magnetometers is being challenged by the recent progress of optically pumped atomic magnetometers operating at room temperature, looking into new opportunities to further improve SQUIDs sensitivity would probably be most welcomed by the SQUID community. By far the most promising such opportunity is to operate a double (D) rf SQUID (an rf-SQUID in which a dc-SQUID is used instead of a single Josephson junction) in a non-adiabatic regime at frequencies of about a few GHz. At these relatively high frequencies required to assure an ultra-high SQUID sensitivity the SQUID-design complexity and the cost of the electronics involved (current generator and SQUID amplifier) are still kept at reasonable levels. The advantages of using this concept, as presented in my contribution in more detail now, are overwhelming. Ironically, although this idea in its preliminary shape has been around for some time now [1], the opportunity has never been explored experimentally! I am just wondering what else needs to be done to get this message across the SQUID community and have this concept finally tested experimentally?
We present a simple model for the thermal magnetic noise in a rf SQUID coupled to a ferromagnetic core via a superconducting dc flux transformer. We show that, under conditions that are almost always fulfilled in practice, the coupling to the core can be described in terms of a SQUID frequency-dependent complex inductance Ls (ω). This inductance reduces to an ordinary, frequency-independent real value above a roll-off frequency ωc . To this inductance, a Nyquist flux noise generator is associated, with spectral density S′2φi(ω) =−4kBT Im[Ls(ω)]/ ω, where kB is the Boltzmann constant, T the temperature, and Im[Ls (ω)] the imaginary part of Ls (ω). If ωc ≪ωrf , with ωrf the frequency of the rf pump, then the response of the SQUID to low-frequency signals is not modified by the coupling to the core, while the above Nyquist noise acts as an additive input noise. We experimentally demonstrate the model for a SQUID coupled to a toroidal core.
Ultrahigh frequency rf-SQUID magnetometer employing a cryogenic preamplifier and a commercially available thin film rf-SQUID sensor have been designed, manufactured, and tested. The system has been operated at 316 MHz, which is the maximum pump frequency accepted by the thin film sensor. The cryogenic preamplifier has been built around a microwave high-electron-mobility transistor which was made unconditionally stable at ultrahigh frequency band by means of an appropriate circuit design, namely, a cascode configuration. The total flux noise of the magnetometer has been found to be 8.4 × 10−6Φ0/√Hz at 4.2 K and 5.8× 10−6Φ0/√Hz at 1.4 K. The temperature dependence of the fractional step rise α of the current-voltage rf characteristic has been measured to be proportional to the 2/3 power of the SQUID sensor temperature. The noise performance of the system at 4.2 K has been limited by the intrinsic SQUID noise only, in good agreement with theoretical predictions.