Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Low-velocity matter wave source for atom interferometry produced by Zeeman-tuned laser cooling and magneto-optic trapping

Shannon K. Mayer

Published Jan 22, 1997• 0 citations
OpenAlex

Related papers

An atomic funnel for atom interferometry

David H. McIntyre, Shannon K. Mayer, N.J. Silva

We have developed a rubidium atomic funnel for use as a matter-wave source in experiments in atom interferometry and atom optics. The funnel utilizes the techniques of laser cooling and trapping to produce a low-velocity beam of cold rubidium atoms. Atoms from a thermal beam are first slowed in a tapered magnetic field using 1D Zeeman slowing. The atoms are then loaded into a 2D magneto-optic trap or atomic funnel. The trap cools and compresses the atoms, which are then ejected from the trap by moving molasses formed with frequency-shifted laser beams. These slow atoms will be diffracted by microfabricated transmission gratings as part of a three-grating atom interferometer.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 1, 1997•1 citation

Matter-Wave Optics and Interferometry with Laser-Cooled Atoms

Michael Christ, Jörg Helge Müller, D. Bettermann +7 more

Springer proceedings in physics•Jan 1, 1994•0 citations

Zeeman slowing and magneto-optically trapping of lithium atoms in atomic interferometry experiments

Yang Wei, Sun Dali, Zhou Lin +2 more

To prepare cold lithium atoms for atomic interferometry experiments, we have carried out experimental researches on Zeeman deceleration and magneto-optical trap (MOT) of lithium atoms. We have also designed and implemented a compact adjustable Zeeman slower with an inner water cooling chamber, to decelerate the velocity of the 7Li atom beam from 600 m/s down to 60 m/s, and load them into the MOT. The loading rate is 5108 /s, the total trapped atom number is 1109 , and the lowest temperature of the atom cloud is 220 30 K. Then we investigate the dependence of lifetime of 7Li atoms in optical molasses on the detuning of trapping laser beams. The above results lay a foundation for further sub-Doppler cooling, optical trap based on evaporative cooling, and atomic interferometry experiments.

Acta Physica Sinica•Jan 1, 2014•6 citations

Atom Optics and Interferometry with Laser Cooled Atoms

Jörg Helge Müller, D. Bettermann, V. Rieger +10 more

AIP conference proceedings•Jan 1, 1994•0 citations

Applications of atom interferometry using an improved laser cooling method

Keng Yeow Chung

•Jan 1, 2001•1 citation

A new design of a compact strontium cold-atom source

Dongyang Xu

A high-flux compact source of strontium atoms has been designed and built. We have investigated the feasibility of direct trapping of cold atoms from the atomic flux out of a hot oven. Our design uses a two-dimensional magneto-optical trap (MOT) with an additional laser beam that exerts a radiation force that is not counterbalanced to eject atoms (so-called ‘push’ beam), which is known as a 2D+ MOT configuration. This approach has been previously used for sodium, and has been extended to strontium in this work. Laser cooling of strontium typically requires multiple stages: effusion of atoms from an oven to produce an atomic beam, transverse collimation, a Zeeman slower and deflection before finally collecting atoms in a 3D MOT. A 2D+ MOT combines the Zeeman slowing, transverse collimation, and deflection into a single compact stage to provide a high-flux source suitable for applications such as matter-wave interferometry, atomic clocks and experimental studies of degenerate quantum gases. This thesis reports experimental work that has been carried out to develop and test an oven and the associated laser cooling apparatus for producing a source of cold strontium atoms which is straightforward to manufacture. We test the oven up to a temperature of To = 642 °C and measure a peak intensity of 6.8 × 1016 s−1 sr−1 and a flux of 2.9 × 1016 s−1. We typically operate the oven at To = 502 °C, for which the peak intensity and flux are 2.2 × 1015 s−1 sr−1 and 7.5 × 1014 s−1. A multi-channel nozzle made of graphite gives an angular divergence of 0.17 rad (10°) for the atomic beam. Trapping atoms directly from the thermal atomic beam into the MOT gives a maximum loading rate of 7.1 × 1010 s−1, without any laser light to repump atoms into the cooling cycle. We demonstrated a novel frequency stabilising technique for the laser by developing Zeeman-tunable modulation transfer spectroscopy in strontium with an inaccuracy of ±3.5 MHz and a frequency tuning range of 160 MHz. The initial aim of this thesis was to make a compact, high-flux strontium source suitable for quantum technology applications. During the course of this research, we participated in the preparation of a proposal for the construction of a large-scale atom interferometer based on the clock transition in strontium (87Sr) for the exploration of dark matter and gravitational waves (a project known as the Atom Interferometer Observatory and Network, AION). This changed the design requirements towards producing a higher flux (in particular of the isotope 87Sr), with compactness of the source being less important in ∼10 m scale apparatus.

•Jan 1, 2020•0 citations
We have developed a rubidium atomic funnel for use as a matter-wave source in experiments in atom interferometry and atom optics. The funnel utilizes the techniques of laser cooling and trapping to produce a low-velocity beam of cold rubidium atoms. Atoms from a thermal beam are first slowed in a tapered magnetic field using 1D Zeeman slowing. The atoms are then loaded into a 2D magneto-optic trap or atomic funnel. The trap cools and compresses the atoms, which are then ejected from the trap by moving molasses formed with frequency-shifted laser beams. These slow atoms will be diffracted by microfabricated transmission gratings as part of a three-grating atom interferometer.
To prepare cold lithium atoms for atomic interferometry experiments, we have carried out experimental researches on Zeeman deceleration and magneto-optical trap (MOT) of lithium atoms. We have also designed and implemented a compact adjustable Zeeman slower with an inner water cooling chamber, to decelerate the velocity of the 7Li atom beam from 600 m/s down to 60 m/s, and load them into the MOT. The loading rate is 5108 /s, the total trapped atom number is 1109 , and the lowest temperature of the atom cloud is 220 30 K. Then we investigate the dependence of lifetime of 7Li atoms in optical molasses on the detuning of trapping laser beams. The above results lay a foundation for further sub-Doppler cooling, optical trap based on evaporative cooling, and atomic interferometry experiments.
A high-flux compact source of strontium atoms has been designed and built. We have investigated the feasibility of direct trapping of cold atoms from the atomic flux out of a hot oven. Our design uses a two-dimensional magneto-optical trap (MOT) with an additional laser beam that exerts a radiation force that is not counterbalanced to eject atoms (so-called ‘push’ beam), which is known as a 2D+ MOT configuration. This approach has been previously used for sodium, and has been extended to strontium in this work. Laser cooling of strontium typically requires multiple stages: effusion of atoms from an oven to produce an atomic beam, transverse collimation, a Zeeman slower and deflection before finally collecting atoms in a 3D MOT. A 2D+ MOT combines the Zeeman slowing, transverse collimation, and deflection into a single compact stage to provide a high-flux source suitable for applications such as matter-wave interferometry, atomic clocks and experimental studies of degenerate quantum gases. This thesis reports experimental work that has been carried out to develop and test an oven and the associated laser cooling apparatus for producing a source of cold strontium atoms which is straightforward to manufacture. We test the oven up to a temperature of To = 642 °C and measure a peak intensity of 6.8 × 1016 s−1 sr−1 and a flux of 2.9 × 1016 s−1. We typically operate the oven at To = 502 °C, for which the peak intensity and flux are 2.2 × 1015 s−1 sr−1 and 7.5 × 1014 s−1. A multi-channel nozzle made of graphite gives an angular divergence of 0.17 rad (10°) for the atomic beam. Trapping atoms directly from the thermal atomic beam into the MOT gives a maximum loading rate of 7.1 × 1010 s−1, without any laser light to repump atoms into the cooling cycle. We demonstrated a novel frequency stabilising technique for the laser by developing Zeeman-tunable modulation transfer spectroscopy in strontium with an inaccuracy of ±3.5 MHz and a frequency tuning range of 160 MHz. The initial aim of this thesis was to make a compact, high-flux strontium source suitable for quantum technology applications. During the course of this research, we participated in the preparation of a proposal for the construction of a large-scale atom interferometer based on the clock transition in strontium (87Sr) for the exploration of dark matter and gravitational waves (a project known as the Atom Interferometer Observatory and Network, AION). This changed the design requirements towards producing a higher flux (in particular of the isotope 87Sr), with compactness of the source being less important in ∼10 m scale apparatus.