Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Wiley eBooks

SQUID Voltmeters and Amplifiers

John L. Clarke, Adrian Tae-Jin Lee, Michael Mück, Paul L. Richards

Published Aug 7, 2006• 6 citations
Publisher

Abstract

This chapter contains sections titled: Introduction Voltmeters The SQUID as a Radiofrequency Amplifier Introduction Mutual Interaction of SQUID and Input Circuit Tuned Amplifier: Theory Untuned Amplifier: Theory Tuned and Untuned Amplifiers: Experiment To Tune or Not to Tune? SQUID Series Array Amplifier The Quantum Limit Future Outlook Microstrip SQUID Amplifier Introduction The Microstrip The Microstrip SQUID Amplifier: Gain The Microstrip SQUID Amplifier: Noise Temperature High-Tc Microstrip SQUID Amplifier Future Outlook SQUID Readout of Thermal Detectors Introduction Transition-Edge Sensors SQUID Multiplexers Time-Domain Multiplexing Frequency-Domain Multiplexing TES Bolometers TES Bolometer Designs Bolometer Performance TES Calorimeters and Nonequilibrium Detectors Calorimeter Designs Calorimeter Noise Performance SQUID Readout of Non-TES Detectors Magnetic Calorimeter SIS Tunnel Junction NIS Junctions Kinetic-Inductance Thermometer Future Outlook Nuclear Magnetic and Quadrupole Resonance and Magnetic Resonance Imaging Introduction Principles of NMR and NQR SQUID-Detected NMR and NQR NQR of 14N Spin Noise NMR of Hyperpolarized 129Xe Liquid-State Proton NMR and MRI Future Outlook The Axion Detector

DOI
10.1002/9783527609956.ch8

Related papers

Nearly Quantum Limited Two-Stage SQUID Amplifiers for the Frequency Domain Multiplexing of TES Based X-ray and Infrared Detectors

Luciano G. Gottardi, M. Kiviranta, Jan van der Kuur +3 more

The frequency domain multiplexing (FDM) readout of arrays of transition edges sensors for the X-IFU/Athena and SAFARI/SPICA instruments requires SQUID amplifiers with low input inductance, low flux noise, high-dynamic range and low power consumption. We report the performance of two-stage SQUID amplifiers developed at VTT coupled to multiple high-Q LC resonators of the SRON FDM readout operating in the frequency range from 2 to 5 MHz. The SQUIDs have been tested in the following configurations: 1) the two SQUIDs at base temperature with open input; 2) the amplifier SQUID at 1K temperature and the front-end SQUID at base temperature in the FDM readout of low-G TES bolometers; and 3) and in the FDM readout of X-ray microcalorimeter arrays with both SQUIDS at base temperature. We measured an input flux noise equal to 0.18 μΦ0/Hz1/2at 20 mK, equivalent to an energy resolution of 9 b. The measured current noise at the SQUID input is ~1 pA/Hz1/2at 20 mK, which corresponds to a coupled energy resolution of about 15 b.

IEEE Transactions on Applied Superconductivity•Nov 10, 2014•15 citations

Nuclear magnetic resonance with dc SQUID (Super-conducting QUantum Interference Device) preamplifiers

N. Q. Fan, Michael B. Heaney, J.E. Clark +5 more

Sensitive radio-frequency (rf) amplifiers based on dc Superconducting QUantum Interface Devices (SQUIDS) are available for frequencies up to 200 MHz. At 4.2 K, the gain and noise temperature of a typical tuned amplifier are 18.6 +- 0.5 dB and 1.7 +- 0.5 K at 93 MHz. These amplifiers are being applied to a series of novel experiments on nuclear magnetic resonance (NMR) and nuclear quadrupole resonance (NQR). The high sensitivity of these amplifiers was demonstrated in the observation of ''nuclear spin noise'', the emission of photons by /sup 35/Cl nuclei in a state of zero polarization. In the more conventional experiments in which one applies a large rf pulse to the spins, a Q-spoiler, consisting of a series array of Josephson junctions, is used to reduce the Q of the input circuit to a very low value during the pulse. The Q-spoiler enables the circuit to recover quickly after the pulse, and has been used in an NQR experiment to achieve a sensitivity of about 2 /times/ 10/sup 16/ nuclear Bohr magnetons in a single free precession signal with a bandwidth of 10 kHz. In a third experiment, a sample containing /sup 35/Cl nuclei was placed in a capacitor and the signal detected electrically using a tuned SQUID amplifier and Q-spoiler. In this way, the electrical polarization induced by the precessing Cl nuclear quadrupole moments was detected: this is the inverse of the Stark effect in NQR. Two experiments involving NMR have been carried out. In the first, the 30 MHz resonance in /sup 119/Sn nuclei is detected with a tuned amplifier and Q-spoiler, and a single pulse resolution of 10/sup 18/ nuclear Bohr magnetons in a bandwidth of 25 kHz has been achieved. For the second, a low frequency NMR system has been developed that uses an untuned input circuit coupled to the SQUID. The resonance in /sup 195/Pt nuclei has been observed at 55 kHz in a field of 60 gauss. 23 refs., 11 figs.

•Aug 1, 1988•0 citations

The Microwave SQUID Multiplexer

J. A. B. Mates

This thesis describes a multiplexer of Superconducting Quantum Interference Devices (SQUIDs) with low-noise, ultra-low power dissipation, and great scalability. The multiplexer circuit measures the magnetic flux in a large number of unshunted rf SQUIDs by coupling each SQUID to a superconducting microwave resonator tuned to a unique resonance frequency and driving the resonators from a common feedline. A superposition of microwave tones measures each SQUID simultaneously using only two coaxial cables between the cryogenic device and room temperature. This multiplexer will enable the instrumentation of arrays with hundreds of thousands of low-temperature detectors for new applications in cosmology, materials analysis, and nuclear non-proliferation.\nThe driving application of the Microwave SQUID Multiplexer is the readout of large arrays of superconducting transition-edge sensors, by some figures of merit the most sensitive detectors of electromagnetic signals over a span of more than nine orders of magnitude in energy, from 40 GHz microwaves to 200 keV gamma rays. Modern transition-edge sensors have noise-equivalent power as low as 10-20 W / [square root] Hz and energy resolution as good as 2 eV at 6 keV. These per-pixel sensitivities approach theoretical limits set by the underlying signals, motivating a rapid increase in pixel count to access new science. Compelling applications, like the non-destructive assay of nuclear material for treaty verification or the search for primordial gravity waves from inflation use arrays of these detectors to increase collection area or tile a focal plane.\nWe developed three generations of SQUID multiplexers, optimizing the first for flux noise (0.17 mu Phi0 / [square root] Hz) the second for input current noise (19 pA / [square root] Hz) and the last for practical multiplexing of large arrays of cosmic microwave background polarimeters based on transition-edge sensors. Using the last design we demonstrated multiplexed readout of prototype polarimeters with the performance required for the future development of a large-scale astronomical instrument.

•Dec 1, 2011•43 citations

Microwave SQUID Multiplexer for TES Readout

Fuminori Hirayama, Satoshi Kohjiro, Daiji Fukuda +3 more

Resonant frequencies and SQUID inductancesLSin a microwave SQUID multiplexer are studied for the purpose of reliable design applicable for a future large-format array of transition edge sensors (TESs). The key element of the multiplexer chip is a quarter-wave-length resonator terminated by a dissipationless rf SQUID connected to TES. For the resonator, we found that a small correction to the effective length of the resonators made the designed resonant frequencies fit the experimental one over the whole readout band of 4-8 GHz covered by our cryogenic amplifier. We also found that microstrip-type SQUIDs with vertical loops are suitable for accurate design of small inductanceLS<; 10<; pH to operate the rf SQUID in dissipationless regime. Based on these well-designed resonators and SQUIDs, we have successfully demonstrated the multiplexing of three pulsed signals with 1-ms width and spacing given at the input ports of three SQUIDs. The equivalent noise current refer to the SQUID input is not dominated by SQUIDs and estimated to be 200-270 pA/ √Hz, whose improvement approach is quantitatively discussed.

IEEE Transactions on Applied Superconductivity•Jan 1, 2013•28 citations

Wideband SQUID Amplifiers for Axion Search Experiments

Andrei N. Matlashov, Yannis Kyriakos Semertzidis

The microwave cavity experiment for the dark matter axion search is based on the theoretical prediction that axions could convert into microwave photons inside a High-Q cavity immersed in a strong magnetic field. In such experiments a weak, of order 10-22 W, quasi-monochromatic microwave signal should be detected by scanning it in a very wide frequency range. The best cryogenic semiconductor amplifiers have the lowest noise temperature plateau of about 1.0 K even at significantly lower ambient temperature. Superconducting quantum interference devices, or SQUIDs, can work as microwave amplifiers with temperature noise close to the standard quantum limit that is about 50 mK at 1 GHz [1]. Previously designed SQUID-based high frequency amplifiers have narrow bandwidth due to a microstrip resonant input coil. It requires serial replacements of SQUID preamplifiers in order to scan wide frequency range. This procedure is complex and time consuming because of a large mass of hardware should be cooled down below 100 mK. For suitable amplification at high frequency a SQUID should be designed with the smallest possible Josephson junction capacitance, reasonably low SQUID loop inductance, and maximal steepness of the transfer function. Sub-micron size cross-type Josephson junctions have a very low capacitance of about 0.04 pF that is one order smaller than a capacitance of Josephson junctions fabricated using conventional window-type technology. Such junctions initially were designed and used at IPHT for low-frequency SQUID current sensors [2]. Slightly modified current sensors were tested as amplifiers at frequency range 0.5 – 5 GHz. They showed high gain and both wideband and resonant performance. In this paper we describe wideband SQUID microwave amplifiers fabricated at IPHT using sub-micron size Josephson junctions with very low capacitance.

International Conference on High Energy Physics (ICHEP)•Aug 2, 2019•0 citations

Two-stage locally linearized SQUID readout for frequency domain multiplexed calorimeter arrays

M. Kiviranta, Leif Grönberg, Hannu Sipola

We have constructed a two-stage SQUID amplifier intended for multiplexed cryogenic detector arrays. The upper SQUID is a locally linearized 6 × 80 array showing 0.13 μΦ 0 Hz − 1/2 flux noise at 4.2 K. The lower linearized 4 × 3 SQUID array has decoupled input and feedback coils and shows 0.28 μΦ 0 Hz − 1/2 flux noise at 4.2 K. Design principles and measured performance are reviewed.

Superconductor Science and Technology•Jan 27, 2011•17 citations
This chapter contains sections titled: Introduction Voltmeters The SQUID as a Radiofrequency Amplifier Introduction Mutual Interaction of SQUID and Input Circuit Tuned Amplifier: Theory Untuned Amplifier: Theory Tuned and Untuned Amplifiers: Experiment To Tune or Not to Tune? SQUID Series Array Amplifier The Quantum Limit Future Outlook Microstrip SQUID Amplifier Introduction The Microstrip The Microstrip SQUID Amplifier: Gain The Microstrip SQUID Amplifier: Noise Temperature High-Tc Microstrip SQUID Amplifier Future Outlook SQUID Readout of Thermal Detectors Introduction Transition-Edge Sensors SQUID Multiplexers Time-Domain Multiplexing Frequency-Domain Multiplexing TES Bolometers TES Bolometer Designs Bolometer Performance TES Calorimeters and Nonequilibrium Detectors Calorimeter Designs Calorimeter Noise Performance SQUID Readout of Non-TES Detectors Magnetic Calorimeter SIS Tunnel Junction NIS Junctions Kinetic-Inductance Thermometer Future Outlook Nuclear Magnetic and Quadrupole Resonance and Magnetic Resonance Imaging Introduction Principles of NMR and NQR SQUID-Detected NMR and NQR NQR of 14N Spin Noise NMR of Hyperpolarized 129Xe Liquid-State Proton NMR and MRI Future Outlook The Axion Detector
The frequency domain multiplexing (FDM) readout of arrays of transition edges sensors for the X-IFU/Athena and SAFARI/SPICA instruments requires SQUID amplifiers with low input inductance, low flux noise, high-dynamic range and low power consumption. We report the performance of two-stage SQUID amplifiers developed at VTT coupled to multiple high-Q LC resonators of the SRON FDM readout operating in the frequency range from 2 to 5 MHz. The SQUIDs have been tested in the following configurations: 1) the two SQUIDs at base temperature with open input; 2) the amplifier SQUID at 1K temperature and the front-end SQUID at base temperature in the FDM readout of low-G TES bolometers; and 3) and in the FDM readout of X-ray microcalorimeter arrays with both SQUIDS at base temperature. We measured an input flux noise equal to 0.18 μΦ0/Hz1/2at 20 mK, equivalent to an energy resolution of 9 b. The measured current noise at the SQUID input is ~1 pA/Hz1/2at 20 mK, which corresponds to a coupled energy resolution of about 15 b.
Sensitive radio-frequency (rf) amplifiers based on dc Superconducting QUantum Interface Devices (SQUIDS) are available for frequencies up to 200 MHz. At 4.2 K, the gain and noise temperature of a typical tuned amplifier are 18.6 +- 0.5 dB and 1.7 +- 0.5 K at 93 MHz. These amplifiers are being applied to a series of novel experiments on nuclear magnetic resonance (NMR) and nuclear quadrupole resonance (NQR). The high sensitivity of these amplifiers was demonstrated in the observation of ''nuclear spin noise'', the emission of photons by /sup 35/Cl nuclei in a state of zero polarization. In the more conventional experiments in which one applies a large rf pulse to the spins, a Q-spoiler, consisting of a series array of Josephson junctions, is used to reduce the Q of the input circuit to a very low value during the pulse. The Q-spoiler enables the circuit to recover quickly after the pulse, and has been used in an NQR experiment to achieve a sensitivity of about 2 /times/ 10/sup 16/ nuclear Bohr magnetons in a single free precession signal with a bandwidth of 10 kHz. In a third experiment, a sample containing /sup 35/Cl nuclei was placed in a capacitor and the signal detected electrically using a tuned SQUID amplifier and Q-spoiler. In this way, the electrical polarization induced by the precessing Cl nuclear quadrupole moments was detected: this is the inverse of the Stark effect in NQR. Two experiments involving NMR have been carried out. In the first, the 30 MHz resonance in /sup 119/Sn nuclei is detected with a tuned amplifier and Q-spoiler, and a single pulse resolution of 10/sup 18/ nuclear Bohr magnetons in a bandwidth of 25 kHz has been achieved. For the second, a low frequency NMR system has been developed that uses an untuned input circuit coupled to the SQUID. The resonance in /sup 195/Pt nuclei has been observed at 55 kHz in a field of 60 gauss. 23 refs., 11 figs.
This thesis describes a multiplexer of Superconducting Quantum Interference Devices (SQUIDs) with low-noise, ultra-low power dissipation, and great scalability. The multiplexer circuit measures the magnetic flux in a large number of unshunted rf SQUIDs by coupling each SQUID to a superconducting microwave resonator tuned to a unique resonance frequency and driving the resonators from a common feedline. A superposition of microwave tones measures each SQUID simultaneously using only two coaxial cables between the cryogenic device and room temperature. This multiplexer will enable the instrumentation of arrays with hundreds of thousands of low-temperature detectors for new applications in cosmology, materials analysis, and nuclear non-proliferation.\nThe driving application of the Microwave SQUID Multiplexer is the readout of large arrays of superconducting transition-edge sensors, by some figures of merit the most sensitive detectors of electromagnetic signals over a span of more than nine orders of magnitude in energy, from 40 GHz microwaves to 200 keV gamma rays. Modern transition-edge sensors have noise-equivalent power as low as 10-20 W / [square root] Hz and energy resolution as good as 2 eV at 6 keV. These per-pixel sensitivities approach theoretical limits set by the underlying signals, motivating a rapid increase in pixel count to access new science. Compelling applications, like the non-destructive assay of nuclear material for treaty verification or the search for primordial gravity waves from inflation use arrays of these detectors to increase collection area or tile a focal plane.\nWe developed three generations of SQUID multiplexers, optimizing the first for flux noise (0.17 mu Phi0 / [square root] Hz) the second for input current noise (19 pA / [square root] Hz) and the last for practical multiplexing of large arrays of cosmic microwave background polarimeters based on transition-edge sensors. Using the last design we demonstrated multiplexed readout of prototype polarimeters with the performance required for the future development of a large-scale astronomical instrument.
Resonant frequencies and SQUID inductancesLSin a microwave SQUID multiplexer are studied for the purpose of reliable design applicable for a future large-format array of transition edge sensors (TESs). The key element of the multiplexer chip is a quarter-wave-length resonator terminated by a dissipationless rf SQUID connected to TES. For the resonator, we found that a small correction to the effective length of the resonators made the designed resonant frequencies fit the experimental one over the whole readout band of 4-8 GHz covered by our cryogenic amplifier. We also found that microstrip-type SQUIDs with vertical loops are suitable for accurate design of small inductanceLS<; 10<; pH to operate the rf SQUID in dissipationless regime. Based on these well-designed resonators and SQUIDs, we have successfully demonstrated the multiplexing of three pulsed signals with 1-ms width and spacing given at the input ports of three SQUIDs. The equivalent noise current refer to the SQUID input is not dominated by SQUIDs and estimated to be 200-270 pA/ √Hz, whose improvement approach is quantitatively discussed.
The microwave cavity experiment for the dark matter axion search is based on the theoretical prediction that axions could convert into microwave photons inside a High-Q cavity immersed in a strong magnetic field. In such experiments a weak, of order 10-22 W, quasi-monochromatic microwave signal should be detected by scanning it in a very wide frequency range. The best cryogenic semiconductor amplifiers have the lowest noise temperature plateau of about 1.0 K even at significantly lower ambient temperature. Superconducting quantum interference devices, or SQUIDs, can work as microwave amplifiers with temperature noise close to the standard quantum limit that is about 50 mK at 1 GHz [1]. Previously designed SQUID-based high frequency amplifiers have narrow bandwidth due to a microstrip resonant input coil. It requires serial replacements of SQUID preamplifiers in order to scan wide frequency range. This procedure is complex and time consuming because of a large mass of hardware should be cooled down below 100 mK. For suitable amplification at high frequency a SQUID should be designed with the smallest possible Josephson junction capacitance, reasonably low SQUID loop inductance, and maximal steepness of the transfer function. Sub-micron size cross-type Josephson junctions have a very low capacitance of about 0.04 pF that is one order smaller than a capacitance of Josephson junctions fabricated using conventional window-type technology. Such junctions initially were designed and used at IPHT for low-frequency SQUID current sensors [2]. Slightly modified current sensors were tested as amplifiers at frequency range 0.5 – 5 GHz. They showed high gain and both wideband and resonant performance. In this paper we describe wideband SQUID microwave amplifiers fabricated at IPHT using sub-micron size Josephson junctions with very low capacitance.