Optomechanical systems provide a versatile platform for precision measurements and investigations of fundamental physics, where bringing macroscopic resonators into the quantum regime is a widely pursued goal. Achieving such quantum behavior of solid-state mechanical resonators at room temperature would greatly broaden their applications by removing the need for cryogenic environments. Reaching this goal requires efficient cooling of mechanical motion, among various laser cooling methods, dynamical backaction cooling (DBC) is widely utilized in experiments but fundamentally limited when operating in the sideband-unresolved regime. Coherent feedback cooling (CFC) can overcome this limitation, while avoiding state collapse and the electronic restrictions inherent to measurement-based feedback. Here, we experimentally demonstrate CFC using an ultracoherent density phononic crystal membrane. By combining CFC with strong DBC in a relatively narrow cavity, we achieve a phonon occupation reduction from
5.5×106 to
166±7, corresponding to a cooling factor of
3.3×104 at room temperature, even with current experimental limitations. Our results show the potential of CFC for approaching the ground state of high-
Q membranes at room temperature.
Abstract Cavity electromechanics relies on parametric coupling between microwave and mechanical modes to manipulate the mechanical quantum state, and provide a coherent interface between different parts of hybrid quantum systems. High coherence of the mechanical mode is of key importance in such applications, in order to protect the quantum states it hosts from thermal decoherence. Here, we introduce an electromechanical system based around a soft-clamped mechanical resonator with an extremely high Q-factor (>109) held at very low (30 mK) temperatures. This ultracoherent mechanical resonator is capacitively coupled to a microwave mode, strong enough to enable ground-state-cooling of the mechanics (
nˉmin=0.76±0.16 n¯min=0.76±0.16 ). This paves the way towards exploiting the extremely long coherence times (tcoh > 100 ms) offered by such systems for quantum information processing and state conversion.