Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2611.08034

Approaching quantum limits in sub-Rayleigh resolution using phase modulation optimization

Chao-Ning Hu, Jun Xin, Xiao-Ming Lu

Published Nov 5, 2026• 0 citations
arXivHTMLPDF

Abstract

Spatial-mode demultiplexing (SPADE) has made significant progress in incoherent optical imaging and has been implemented through various experimental approaches. Holography-based SPADE is widely used in proof-of-principle experiments because of its low cost, stable optical arrangement, and ease of implementation. However, its low photon utilization severely limits its practical applications. Alternating Fourier transforms and phase modulations can implement unitary optical transformations. Building on this idea, we use backpropagation to optimize the phase profiles of spatial light modulators (SLMs) and thereby design quantum measurements that are efficient in both information and energy. We study centroid--separation estimation for two incoherent point sources, using Fisher information or the estimation errors of an auxiliary neural network estimator as optimization objectives. As the number of SLMs increases, the optimized measurements approach the quantum limits characterized by the quantum Cramér-Rao bound and the information-regret tradeoff relation. With a few SLMs, our method can outperform direct imaging, showing its potential for superresolution imaging.

DOI
10.48550/arxiv.2611.08034

Related papers

Superresolving optical ruler based on spatial mode demultiplexing for systems evolving under Brownian motion

Konrad Schlichtholz

The development of super-resolution techniques, i.e., allowing for efficient resolution below the Rayleigh limit, became one of the important branches in contemporary optics and metrology. Recent findings show that perfect spatial mode demultiplexing (SPADE) into Hermite-Gauss modes followed by photon counting enables one to reach the quantum limit of precision in the task of estimation of separation between two weak stationary sources in the sub-Rayleigh regime. In order to check the limitations of the method, various imperfections such as misalignment or crosstalk between the modes were considered. Possible applications of the method in microscopy call for the adaptive measurement scheme, as the position of the measured system can evolve in time, causing non-negligible misalignment. In this paper, we examine the impact of Brownian motion of the center of the system of two weak incoherent sources on adaptive SPADE measurement precision limits. The analysis is carried out using Fisher information, from which the limit of precision can be obtained by Cramér-Rao bound. As a result, we find that Rayleigh's curse is present in such a scenario; however, SPADE measurement can outperform perfect direct imaging. What is more, a suitable adjustment of the measurement time between alignments allows measurement with near-optimal precision.

arXiv:2407.13723•Physics of Fluids•Feb 1, 2025•1 citation

Multiparameter estimation for the superresolution of two incoherent sources

Antonin Grateau, Alexander Boeschoten, Tanguy Favin-Lévêque +2 more

We experimentally demonstrate the simultaneous estimation of the three parameters characterizing a pair of incoherent optical sources in the sub-Rayleigh regime, enabling super-resolved scene characterization. Using spatial-mode demultiplexing (SPADE) with two demultiplexers--one deliberately shifted--we determine separations well below the diffraction limit and achieve sensitive joint estimation of separation, centroid, and relative brightness over a broad range of scene configurations in a single experimental setting. We benchmark our performance using Fisher-information-based Cramér-Rao bounds, and discuss the corresponding quantum limits. We investigate two complementary scenarios: a realistic case with slightly non-identical sources, and an idealized case of indistinguishable sources.

quant-pharXiv:2601.14876•Physical Review Letters•Jan 22, 2026•2 citations

Passive optical superresolution at the quantum limit

A. I. Lvovsky, Michael R. Grace, Saikat Guha +3 more

For more than a century, the diffraction limit has defined the resolution achievable by passive optical imaging systems. Although some resolution improvement can be gained through classical data processing of the image, it is limited by the noise arising from quantum nature of light. Minimizing the effect of this noise requires quantum treatment of optical imaging. By reformulating imaging as a problem of quantum measurement and estimation, it becomes possible to identify optimal detection strategies that recover spatial information previously thought inaccessible. This review summarizes the theoretical framework that underpins this development, from the formulation of quantum Cramer-Rao bounds and Chernoff bounds to the construction of receivers that attain them, such as those based on spatial-mode demultiplexing. We show how these methods can beat conventional imaging in the classification, localization, and imaging of sub-Rayleigh incoherent sources. We then discuss extensions to multiparameter and partially coherent scenarios, and highlight the unifying connections between estimation and discrimination tasks. Finally, we survey recent experimental demonstrations that approach quantum-limited resolution and outline emerging applications in microscopy, astronomy, and optical sensing.

quant-pharXiv:2605.10767•Optica•May 12, 2026•14 citations

Quantum-inspired superresolution for incoherent imaging

Xiaojie Tan, Qi Luo, Lianwei Chen +3 more

Optical measurements that can achieve the fundamental quantum limits have the potential to improve the imaging of subdiffraction objects in important applications, including optical astronomy and fluorescence microscopy. Working towards the goal of implementing such quantum-inspired measurements for real applications, we experimentally demonstrate the localization of two incoherent optical point sources and the semiparametric estimation of object moments in the subdiffraction regime via spatial-mode demultiplexing (SPADE). In the case of two sources, we are able to estimate both of their locations accurately, not just their separation, by exploiting the asymmetric response of our SPADE device. In the case of semiparametric estimation, we demonstrate that, even if the source number is unknown, the moments of the source distribution can still be estimated accurately. Our demonstration paves the way towards the use of SPADE for optical superresolution in practical scenarios, where adaptive measurements are difficult and many parameters are unknown.

Optica•Jul 27, 2023•42 citations

Superresolution Enhancement in Biphoton Spatial-Mode Demultiplexing

Florence Grenapin, Dilip Paneru, Alessio D’Errico +3 more

Imaging systems measuring intensity in the far field succumb to Rayleigh's curse, a resolution limitation dictated by the finite aperture of the optical system. Many proof-of-principle and some two-dimensional imaging experiments have shown that, by using spatial mode demultiplexing (SPADE), the field information collected is maximal, and, thus, the resolution increases beyond the Rayleigh criterion. Hitherto, the SPADE approaches are based on resolving the lateral splitting of a Gaussian wave function. Here, we consider the case in which the light field originates from a biphoton source, i.e., spontaneous parametric down-conversion, and a horizontal separation is introduced in one of the two photons. We show that a separation induced in the signal photon arm can be superresolved using coincidence measurements after projecting both photons on Hermite-Gauss modes. Remarkably, the Fisher information associated with the measurement is enhanced compared to the ordinary SPADE techniques by $\sqrt{K}$, where $K$ is the Schmidt number of the two-photon state that quantifies the amount of spatial entanglement between the two photons.

arXiv:2212.10468•Physical Review Applied•Aug 31, 2023•14 citations

Subdiffraction incoherent optical imaging via spatial-mode demultiplexing: Semiclassical treatment

Mankei Tsang

I present a semiclassical analysis of a spatial-mode demultiplexing (SPADE) measurement scheme for far-field incoherent optical imaging under the effects of diffraction and photon shot noise. Building on previous results that assume two point sources or the Gaussian point-spread function, I generalize SPADE for a larger class of point-spread functions and evaluate its errors in estimating the moments of an arbitrary subdiffraction object. Compared with the limits to direct imaging set by the Cram\'er-Rao bounds, the results show that SPADE can offer far superior accuracy in estimating second- and higher-order moments.

arXiv:1703.08833•Physical Review A•Feb 21, 2018•55 citations
Spatial-mode demultiplexing (SPADE) has made significant progress in incoherent optical imaging and has been implemented through various experimental approaches. Holography-based SPADE is widely used in proof-of-principle experiments because of its low cost, stable optical arrangement, and ease of implementation. However, its low photon utilization severely limits its practical applications. Alternating Fourier transforms and phase modulations can implement unitary optical transformations. Building on this idea, we use backpropagation to optimize the phase profiles of spatial light modulators (SLMs) and thereby design quantum measurements that are efficient in both information and energy. We study centroid--separation estimation for two incoherent point sources, using Fisher information or the estimation errors of an auxiliary neural network estimator as optimization objectives. As the number of SLMs increases, the optimized measurements approach the quantum limits characterized by the quantum Cramér-Rao bound and the information-regret tradeoff relation. With a few SLMs, our method can outperform direct imaging, showing its potential for superresolution imaging.
The development of super-resolution techniques, i.e., allowing for efficient resolution below the Rayleigh limit, became one of the important branches in contemporary optics and metrology. Recent findings show that perfect spatial mode demultiplexing (SPADE) into Hermite-Gauss modes followed by photon counting enables one to reach the quantum limit of precision in the task of estimation of separation between two weak stationary sources in the sub-Rayleigh regime. In order to check the limitations of the method, various imperfections such as misalignment or crosstalk between the modes were considered. Possible applications of the method in microscopy call for the adaptive measurement scheme, as the position of the measured system can evolve in time, causing non-negligible misalignment. In this paper, we examine the impact of Brownian motion of the center of the system of two weak incoherent sources on adaptive SPADE measurement precision limits. The analysis is carried out using Fisher information, from which the limit of precision can be obtained by Cramér-Rao bound. As a result, we find that Rayleigh's curse is present in such a scenario; however, SPADE measurement can outperform perfect direct imaging. What is more, a suitable adjustment of the measurement time between alignments allows measurement with near-optimal precision.
We experimentally demonstrate the simultaneous estimation of the three parameters characterizing a pair of incoherent optical sources in the sub-Rayleigh regime, enabling super-resolved scene characterization. Using spatial-mode demultiplexing (SPADE) with two demultiplexers--one deliberately shifted--we determine separations well below the diffraction limit and achieve sensitive joint estimation of separation, centroid, and relative brightness over a broad range of scene configurations in a single experimental setting. We benchmark our performance using Fisher-information-based Cramér-Rao bounds, and discuss the corresponding quantum limits. We investigate two complementary scenarios: a realistic case with slightly non-identical sources, and an idealized case of indistinguishable sources.
For more than a century, the diffraction limit has defined the resolution achievable by passive optical imaging systems. Although some resolution improvement can be gained through classical data processing of the image, it is limited by the noise arising from quantum nature of light. Minimizing the effect of this noise requires quantum treatment of optical imaging. By reformulating imaging as a problem of quantum measurement and estimation, it becomes possible to identify optimal detection strategies that recover spatial information previously thought inaccessible. This review summarizes the theoretical framework that underpins this development, from the formulation of quantum Cramer-Rao bounds and Chernoff bounds to the construction of receivers that attain them, such as those based on spatial-mode demultiplexing. We show how these methods can beat conventional imaging in the classification, localization, and imaging of sub-Rayleigh incoherent sources. We then discuss extensions to multiparameter and partially coherent scenarios, and highlight the unifying connections between estimation and discrimination tasks. Finally, we survey recent experimental demonstrations that approach quantum-limited resolution and outline emerging applications in microscopy, astronomy, and optical sensing.
Optical measurements that can achieve the fundamental quantum limits have the potential to improve the imaging of subdiffraction objects in important applications, including optical astronomy and fluorescence microscopy. Working towards the goal of implementing such quantum-inspired measurements for real applications, we experimentally demonstrate the localization of two incoherent optical point sources and the semiparametric estimation of object moments in the subdiffraction regime via spatial-mode demultiplexing (SPADE). In the case of two sources, we are able to estimate both of their locations accurately, not just their separation, by exploiting the asymmetric response of our SPADE device. In the case of semiparametric estimation, we demonstrate that, even if the source number is unknown, the moments of the source distribution can still be estimated accurately. Our demonstration paves the way towards the use of SPADE for optical superresolution in practical scenarios, where adaptive measurements are difficult and many parameters are unknown.
Imaging systems measuring intensity in the far field succumb to Rayleigh's curse, a resolution limitation dictated by the finite aperture of the optical system. Many proof-of-principle and some two-dimensional imaging experiments have shown that, by using spatial mode demultiplexing (SPADE), the field information collected is maximal, and, thus, the resolution increases beyond the Rayleigh criterion. Hitherto, the SPADE approaches are based on resolving the lateral splitting of a Gaussian wave function. Here, we consider the case in which the light field originates from a biphoton source, i.e., spontaneous parametric down-conversion, and a horizontal separation is introduced in one of the two photons. We show that a separation induced in the signal photon arm can be superresolved using coincidence measurements after projecting both photons on Hermite-Gauss modes. Remarkably, the Fisher information associated with the measurement is enhanced compared to the ordinary SPADE techniques by K\sqrt{K}K​, where KKK is the Schmidt number of the two-photon state that quantifies the amount of spatial entanglement between the two photons.
I present a semiclassical analysis of a spatial-mode demultiplexing (SPADE) measurement scheme for far-field incoherent optical imaging under the effects of diffraction and photon shot noise. Building on previous results that assume two point sources or the Gaussian point-spread function, I generalize SPADE for a larger class of point-spread functions and evaluate its errors in estimating the moments of an arbitrary subdiffraction object. Compared with the limits to direct imaging set by the Cram\'er-Rao bounds, the results show that SPADE can offer far superior accuracy in estimating second- and higher-order moments.