Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2611.07271

Upper and lower bounds for few-copy Gaussian tomography, and the absence of a fermionic warm regime

Ron Rubin

Published Nov 5, 2026• 1 citation
arXivHTMLPDF

Abstract

Chen, Mele, Mele and Preskill proved a crossover for bosonic Gaussian tomography: cold states need $Θ(m^3/ε^2)$ copies under single-copy or few-copy measurements, warm ones $Θ(m^2/ε^2)$. The author proved $Ω(m^3/ε^2)$ for adaptive single-copy tomography of mixed fermionic Gaussian states. This note shows the crossover has no fermionic counterpart and extends the fermionic bound to blocks of $k$ copies. There is no warm regime: on the quadratic Gibbs balls $β\|h\|_F\leβ_0$ of unknown Hamiltonian $h$, the single-copy rate is $Θ(m^3/ε^2)$ for every fixed $β_0>0$, at accuracies that resolve the ball, with a lower-bound constant independent of $β_0$. At the maximally mixed state a replicated-parameter Fisher budget gives $N>m^3/(8{,}553{,}600\,k\,ε^2)$ for blocks of at most $k$ copies and all $ε\le1/3600$; an exact formula for the maximal block Fisher information, via spinor tensor powers of $\mathfrak{so}(2m)$, shows that the budget $mt^2$ behind it is asymptotically attained for every fixed block size; whether $1/k$ is the true rate is open. Near the vacuum, block protocols need $Ω(m^3/(ε^2\min\{\sqrt k,m\}))$ copies, with no logarithm, via an exterior-power embedding of qudit tomography; parity superselection changes no rate, and number superselection costs nothing on number-conserving inputs. The embedding also carries upper bounds: a particle-number measurement followed by the $k$-copy qudit protocol of Nayak and Zhou attains the lower bound for every $k$ on number-conserving fermionic Gaussian states with bounded fugacity trace and on passive bosonic Gaussian states with bounded photon number, and a heterodyne stage that undoes displacement and squeezing extends this to all cold bosonic Gaussian states. This closes their $k$-entangled gap on the cold class; intermediate temperatures remain open.

DOI
10.48550/arxiv.2611.07271

Related papers

Entangled measurements are necessary for optimal tomography of mixed fermionic Gaussian states and of bosonic Gaussian states near the vacuum

Ron Rubin

We prove that learning an unknown mixed fermionic Gaussian state on $m$ modes to trace distance $ε$ requires $Ω(m^3/ε^2)$ copies when measurements act on one copy at a time, even with arbitrary POVMs, fresh ancillas and classical adaptivity, but without quantum memory between copies. The bound holds for $0<ε\le1/3600$ and separates this model from the known collective rate $Θ(m^2/ε^2)$. It follows from a uniform single-copy Fisher-information budget and a dimension-independent comparison between trace distance and Gaussian parameters. On covariance matrices of operator norm at most $1-c$, we prove a Frobenius-to-trace-norm continuity bound with constant $[2c(2-c)]^{-1/2}$; matchgate shadows then attain $O(m^3/(cε^2))$ copies. This also gives explicit error certificates for thermal free-fermion states. For a class of mixed passive bosonic Gaussian states with total mean photon number at most one, a reduction to bounded-block qudit tomography gives a single-copy lower bound $Ω(m^3/(ε^2\sqrt{\log(m/ε)}))$, versus collective complexity $Θ(m^2/ε^2)$. These separations answer the mixed-state measurement-resource question posed by Chen et al. A two-mode example has optimal two-copy Fisher trace $5$, versus the separable ceiling $4$. An IBM replication gave a pre-registered witness lower bound $4.12$ at one-sided $95\%$ shot-noise confidence; its interpretation assumes the prescribed preparations and a common measurement channel and does not bound preparation systematics.

quant-pharXiv:2609.23189•Sep 22, 2026•4 citations

Tight Lower Bounds for State Tomography with Limited Entanglement

Ufuk Keskin, Jason Luo, Mahbod Majid +1 more

We study state tomography when each measurement acts on at most $k$ fresh copies and no quantum memory is retained between blocks. We prove a lower bound matching the upper bound in [arXiv:2510.07788]. Thus the copy complexity of estimating an arbitrary $d$-dimensional state to trace distance $ε$ is, up to absolute constant factors, $\max\{d^3/(\sqrt{k}ε^2),d^2/ε^2\}$ for every $k$ and all sufficiently small $ε$. This removes the earlier restriction that $k$ be small as a function of the accuracy. The lower bound applies to arbitrary measurements within each block and adaptive choices between blocks. The lower bound already applies in a small neighborhood of any state whose smallest eigenvalue is of order $1/d$, even when the center is known. The main ingredient is a uniform Fisher information bound for one measurement block that depends only on the smallest eigenvalue of the state. The proof avoids the perturbative expansion responsible for the restriction in [arXiv:2402.16353]. Fano's inequality for metric balls and a log-Sobolev comparison between mutual and Fisher information then reduce the adaptive protocol to this block bound [arXiv:1607.00550, arXiv:1902.08582].

quant-pharXiv:2609.05718•Sep 8, 2026•8 citations

When are bosonic Gaussian states classical to learn?

Senrui Chen, Antonio Anna Mele, Francesco Anna Mele +1 more

A fundamental question in physics is: When does classical behavior emerge from quantum systems? Bosonic Gaussian states provide a natural setting to explore this quantum-classical boundary, as they capture both the classical field behavior and the intrinsic quantum nature of light. Here, we address this problem from a learning-theoretic perspective by asking: When are bosonic Gaussian states classical to learn? That is, under what conditions (if any) can an n-mode bosonic Gaussian state be learned with as few samples, and with operations as simple, as are needed to learn a classical 2n-variate Gaussian distribution? We establish a smooth crossover in learnability governed by the state's thermal fluctuations: - Cold Gaussian states are non-classical to learn: When the covariance matrix satisfies $Σ\le(\frac12+O(\frac1n))I$, i.e. close to the vacuum covariance, tomography under single-copy (i.e., non-entangled) measurements fundamentally requires $Ω(n^3)$ copies, strictly exceeding the sample complexity $Θ(n^2)$ of learning classical Gaussian distributions. We show that this hardness persists even when few-copy entangled measurements are allowed. - Warm Gaussian states are classical to learn: When thermal fluctuations exceed the vacuum noise, parameterized by $Σ\ge(\frac12+ν)I$ for any parameter $ν>0$, we prove that single-copy tomography requires $N=Θ\left(n^2\min(n,1+ν^{-1})\right)$ copies. This bound is tight and is achieved by simple, non-adaptive, unentangled heterodyne measurements. Crucially, for $ν=Ω(1)$, the sample complexity drops to $Θ(n^2)$, matching the classical case. Our results tightly characterize a quantum-to-classical crossover in the learnability of bosonic Gaussian states, reveal a novel connection between fundamental physics and statistical learning theory, and have implications for real-world sensing experiments.

quant-pharXiv:2609.26705•Sep 23, 2026•3 citations

What resources are needed for optimal learning of bosonic Gaussian states?

Senrui Chen, Francesco Anna Mele, Marco Fanizza +5 more

Continuous-variable systems enable key quantum technologies in computation, communication, and sensing. Bosonic Gaussian states emerge naturally in various such applications, including gravitational-wave and dark-matter detection. A fundamental question is how to characterize an unknown bosonic Gaussian state from as few samples as possible. Despite decades-long exploration, the ultimate efficiency limit remains unclear. In this work, we study the necessary and sufficient number of copies to learn an $n$-mode Gaussian state, with energy less than $E$, to $\varepsilon$ trace distance with high probability. We prove a lower bound of $Ω(n^3/\varepsilon^2)$ for Gaussian measurements, matching the best known upper bound up to doubly-log energy dependence, and $Ω(n^2/\varepsilon^2)$ for arbitrary measurements. We further show an upper bound of $\widetilde{O}(n^2/\varepsilon^2)$ given that the Gaussian state is promised to be either pure or passive. Interestingly, while Gaussian measurements suffice for nearly optimal learning of pure Gaussian states, non-Gaussian measurements are provably required for optimal learning of passive Gaussian states. Finally, focusing on learning single-mode Gaussian states via non-entangling Gaussian measurements, we provide a nearly tight bound of $\widetildeΘ(E/\varepsilon^2)$ for any non-adaptive schemes, showing adaptivity is indispensable for nearly energy-independent scaling. As a byproduct, we establish sharp bounds on the trace distance between Gaussian states in terms of the total variation distance between their Wigner distributions, and obtain a nearly tight sample complexity bound for learning the Wigner distribution of any Gaussian state to $\varepsilon$ total variation distance. Our results significantly advance quantum learning theory in the bosonic regimes and have practical impact in quantum sensing and benchmarking applications.

quant-pharXiv:2603.18136•Mar 20, 2026•14 citations

Sample complexity of learning fermionic and bosonic Gaussian states with single-copy and entangled measurements

Ron Rubin

With single-copy measurements, every mixed fermionic Gaussian state on $m$ modes, pure modes included, is learned to trace distance $ε$ from $Θ(m^3/ε^2)$ copies, with no logarithmic factor, against the known $Θ(m^2/ε^2)$ for collective measurements. We prove the upper bound, resolving Conjecture 10.1 of arXiv:2609.23189 (lower bound for $ε\le1/3600$), and fill most open entries of the sample-complexity table of fermionic and bosonic Gaussian states, for single-copy, $k$-copy and collective measurements. The single-copy measurement's noise is matched to the metric at every occupation scale. With blocks of $k$ copies, the covariant highest-weight measurement of arXiv:2611.07271, read out through the Weyl-shift estimator, is exactly unbiased for every state; it gives $Θ(\max\{m^3/k,m^2\}/ε^2)$ in Frobenius norm on all states and in trace distance on every class at a fixed distance from the pure boundary. The gain $1/k$ ($k\le m$) away from the pure boundary, against $1/\sqrt k$ on cold number-conserving states, is therefore attained. For bosonic Gaussian states with bounded covariance, any displacement and squeezing, and occupations $n_1\le\dots\le n_m$, $O((m^2+r^3+\sum_{i,j>r}1/(n_i+n_j))/ε^2)$ single-copy measurements suffice, $r$ the largest index with $r\,n_r\le2$; this is the minimax rate on dyadic-interval classes, with no spectral gap or cold-mode count assumed, and holds with no covariance bound for displaced passive states. With no bound on energy or squeezing, non-Gaussian measurements learn centred one-mode states, mixed included, from $O(ε^{-2})$ and centred pure $m$-mode states from $O(m^2/ε^2)$ single copies, free of the $\log\log E$ term of Gaussian measurements, and $m$-mode states from $O(m^3/ε^2)$ copies, entangled only in a first round on blocks of $4m+6$.

arXiv:2611.13428•Nov 10, 2026•0 citations

The log log jam in Gaussian state tomography

Sitan Chen, Weiyuan Gong, Qi Ye +1 more

Unlike in finite dimensions, quantum information in continuous-variable systems has the peculiar feature that without imposing physical constraints, the sample complexity of state tomography can be unbounded. Remarkably, this is even the case for state-of-the-art protocols for learning Gaussian states, which have finite-dimensional descriptions: the best known rates scale with $\log \log E$, where $E$ is the energy of the system. We prove this is not an artifact of existing analyses, but a fundamental limitation of the measurements used. We show: (1) Any protocol that uses Gaussian measurements, even entangled or adaptively chosen ones, must incur a $\log \log E$ dependence. This answers an open question posed by a number of previous works. (2) There is a smooth tradeoff between the number of rounds of adaptivity and the energy dependence, and we give a matching protocol achieving this interpolated rate. (3) With highly entangled, non-Gaussian measurements, one can learn $n$-mode pure Gaussian states with $O(n^2 / ε^2)$ samples, independent of $E$. This answers an open question posed by Chen et al. (4) A simple protocol based on the single-copy canonical phase POVM of Holevo and Helstrom learns single-mode pure Gaussian states with $O(1/ε^2)$ samples, again independent of $E$. Our results clarify the role of energy in bosonic state tomography and shed new light on the intriguing interplay between adaptivity, entanglement, and magic in quantum learning.

quant-pharXiv:2607.12983•Jul 15, 2026•7 citations
Chen, Mele, Mele and Preskill proved a crossover for bosonic Gaussian tomography: cold states need Θ(m3/ε2)Θ(m^3/ε^2)Θ(m3/ε2) copies under single-copy or few-copy measurements, warm ones Θ(m2/ε2)Θ(m^2/ε^2)Θ(m2/ε2). The author proved Ω(m3/ε2)Ω(m^3/ε^2)Ω(m3/ε2) for adaptive single-copy tomography of mixed fermionic Gaussian states. This note shows the crossover has no fermionic counterpart and extends the fermionic bound to blocks of kkk copies. There is no warm regime: on the quadratic Gibbs balls β∥h∥F≤β0β\|h\|_F\leβ_0β∥h∥F​≤β0​ of unknown Hamiltonian hhh, the single-copy rate is Θ(m3/ε2)Θ(m^3/ε^2)Θ(m3/ε2) for every fixed β0>0β_0>0β0​>0, at accuracies that resolve the ball, with a lower-bound constant independent of β0β_0β0​. At the maximally mixed state a replicated-parameter Fisher budget gives N>m3/(8,553,600 k ε2)N>m^3/(8{,}553{,}600\,k\,ε^2)N>m3/(8,553,600kε2) for blocks of at most kkk copies and all ε≤1/3600ε\le1/3600ε≤1/3600; an exact formula for the maximal block Fisher information, via spinor tensor powers of so(2m)\mathfrak{so}(2m)so(2m), shows that the budget mt2mt^2mt2 behind it is asymptotically attained for every fixed block size; whether 1/k1/k1/k is the true rate is open. Near the vacuum, block protocols need Ω(m3/(ε2min⁡{k,m}))Ω(m^3/(ε^2\min\{\sqrt k,m\}))Ω(m3/(ε2min{k​,m})) copies, with no logarithm, via an exterior-power embedding of qudit tomography; parity superselection changes no rate, and number superselection costs nothing on number-conserving inputs. The embedding also carries upper bounds: a particle-number measurement followed by the kkk-copy qudit protocol of Nayak and Zhou attains the lower bound for every kkk on number-conserving fermionic Gaussian states with bounded fugacity trace and on passive bosonic Gaussian states with bounded photon number, and a heterodyne stage that undoes displacement and squeezing extends this to all cold bosonic Gaussian states. This closes their kkk-entangled gap on the cold class; intermediate temperatures remain open.
We prove that learning an unknown mixed fermionic Gaussian state on mmm modes to trace distance εεε requires Ω(m3/ε2)Ω(m^3/ε^2)Ω(m3/ε2) copies when measurements act on one copy at a time, even with arbitrary POVMs, fresh ancillas and classical adaptivity, but without quantum memory between copies. The bound holds for 0<ε≤1/36000<ε\le1/36000<ε≤1/3600 and separates this model from the known collective rate Θ(m2/ε2)Θ(m^2/ε^2)Θ(m2/ε2). It follows from a uniform single-copy Fisher-information budget and a dimension-independent comparison between trace distance and Gaussian parameters. On covariance matrices of operator norm at most 1−c1-c1−c, we prove a Frobenius-to-trace-norm continuity bound with constant [2c(2−c)]−1/2[2c(2-c)]^{-1/2}[2c(2−c)]−1/2; matchgate shadows then attain O(m3/(cε2))O(m^3/(cε^2))O(m3/(cε2)) copies. This also gives explicit error certificates for thermal free-fermion states. For a class of mixed passive bosonic Gaussian states with total mean photon number at most one, a reduction to bounded-block qudit tomography gives a single-copy lower bound Ω(m3/(ε2log⁡(m/ε)))Ω(m^3/(ε^2\sqrt{\log(m/ε)}))Ω(m3/(ε2log(m/ε)​)), versus collective complexity Θ(m2/ε2)Θ(m^2/ε^2)Θ(m2/ε2). These separations answer the mixed-state measurement-resource question posed by Chen et al. A two-mode example has optimal two-copy Fisher trace 555, versus the separable ceiling 444. An IBM replication gave a pre-registered witness lower bound 4.124.124.12 at one-sided 95%95\%95% shot-noise confidence; its interpretation assumes the prescribed preparations and a common measurement channel and does not bound preparation systematics.
We study state tomography when each measurement acts on at most kkk fresh copies and no quantum memory is retained between blocks. We prove a lower bound matching the upper bound in [arXiv:2510.07788]. Thus the copy complexity of estimating an arbitrary ddd-dimensional state to trace distance εεε is, up to absolute constant factors, max⁡{d3/(kε2),d2/ε2}\max\{d^3/(\sqrt{k}ε^2),d^2/ε^2\}max{d3/(k​ε2),d2/ε2} for every kkk and all sufficiently small εεε. This removes the earlier restriction that kkk be small as a function of the accuracy. The lower bound applies to arbitrary measurements within each block and adaptive choices between blocks. The lower bound already applies in a small neighborhood of any state whose smallest eigenvalue is of order 1/d1/d1/d, even when the center is known. The main ingredient is a uniform Fisher information bound for one measurement block that depends only on the smallest eigenvalue of the state. The proof avoids the perturbative expansion responsible for the restriction in [arXiv:2402.16353]. Fano's inequality for metric balls and a log-Sobolev comparison between mutual and Fisher information then reduce the adaptive protocol to this block bound [arXiv:1607.00550, arXiv:1902.08582].
A fundamental question in physics is: When does classical behavior emerge from quantum systems? Bosonic Gaussian states provide a natural setting to explore this quantum-classical boundary, as they capture both the classical field behavior and the intrinsic quantum nature of light. Here, we address this problem from a learning-theoretic perspective by asking: When are bosonic Gaussian states classical to learn? That is, under what conditions (if any) can an n-mode bosonic Gaussian state be learned with as few samples, and with operations as simple, as are needed to learn a classical 2n-variate Gaussian distribution? We establish a smooth crossover in learnability governed by the state's thermal fluctuations: - Cold Gaussian states are non-classical to learn: When the covariance matrix satisfies Σ≤(12+O(1n))IΣ\le(\frac12+O(\frac1n))IΣ≤(21​+O(n1​))I, i.e. close to the vacuum covariance, tomography under single-copy (i.e., non-entangled) measurements fundamentally requires Ω(n3)Ω(n^3)Ω(n3) copies, strictly exceeding the sample complexity Θ(n2)Θ(n^2)Θ(n2) of learning classical Gaussian distributions. We show that this hardness persists even when few-copy entangled measurements are allowed. - Warm Gaussian states are classical to learn: When thermal fluctuations exceed the vacuum noise, parameterized by Σ≥(12+ν)IΣ\ge(\frac12+ν)IΣ≥(21​+ν)I for any parameter ν>0ν>0ν>0, we prove that single-copy tomography requires N=Θ(n2min⁡(n,1+ν−1))N=Θ\left(n^2\min(n,1+ν^{-1})\right)N=Θ(n2min(n,1+ν−1)) copies. This bound is tight and is achieved by simple, non-adaptive, unentangled heterodyne measurements. Crucially, for ν=Ω(1)ν=Ω(1)ν=Ω(1), the sample complexity drops to Θ(n2)Θ(n^2)Θ(n2), matching the classical case. Our results tightly characterize a quantum-to-classical crossover in the learnability of bosonic Gaussian states, reveal a novel connection between fundamental physics and statistical learning theory, and have implications for real-world sensing experiments.
Continuous-variable systems enable key quantum technologies in computation, communication, and sensing. Bosonic Gaussian states emerge naturally in various such applications, including gravitational-wave and dark-matter detection. A fundamental question is how to characterize an unknown bosonic Gaussian state from as few samples as possible. Despite decades-long exploration, the ultimate efficiency limit remains unclear. In this work, we study the necessary and sufficient number of copies to learn an nnn-mode Gaussian state, with energy less than EEE, to ε\varepsilonε trace distance with high probability. We prove a lower bound of Ω(n3/ε2)Ω(n^3/\varepsilon^2)Ω(n3/ε2) for Gaussian measurements, matching the best known upper bound up to doubly-log energy dependence, and Ω(n2/ε2)Ω(n^2/\varepsilon^2)Ω(n2/ε2) for arbitrary measurements. We further show an upper bound of O~(n2/ε2)\widetilde{O}(n^2/\varepsilon^2)O(n2/ε2) given that the Gaussian state is promised to be either pure or passive. Interestingly, while Gaussian measurements suffice for nearly optimal learning of pure Gaussian states, non-Gaussian measurements are provably required for optimal learning of passive Gaussian states. Finally, focusing on learning single-mode Gaussian states via non-entangling Gaussian measurements, we provide a nearly tight bound of Θ~(E/ε2)\widetildeΘ(E/\varepsilon^2)Θ(E/ε2) for any non-adaptive schemes, showing adaptivity is indispensable for nearly energy-independent scaling. As a byproduct, we establish sharp bounds on the trace distance between Gaussian states in terms of the total variation distance between their Wigner distributions, and obtain a nearly tight sample complexity bound for learning the Wigner distribution of any Gaussian state to ε\varepsilonε total variation distance. Our results significantly advance quantum learning theory in the bosonic regimes and have practical impact in quantum sensing and benchmarking applications.
With single-copy measurements, every mixed fermionic Gaussian state on mmm modes, pure modes included, is learned to trace distance εεε from Θ(m3/ε2)Θ(m^3/ε^2)Θ(m3/ε2) copies, with no logarithmic factor, against the known Θ(m2/ε2)Θ(m^2/ε^2)Θ(m2/ε2) for collective measurements. We prove the upper bound, resolving Conjecture 10.1 of arXiv:2609.23189 (lower bound for ε≤1/3600ε\le1/3600ε≤1/3600), and fill most open entries of the sample-complexity table of fermionic and bosonic Gaussian states, for single-copy, kkk-copy and collective measurements. The single-copy measurement's noise is matched to the metric at every occupation scale. With blocks of kkk copies, the covariant highest-weight measurement of arXiv:2611.07271, read out through the Weyl-shift estimator, is exactly unbiased for every state; it gives Θ(max⁡{m3/k,m2}/ε2)Θ(\max\{m^3/k,m^2\}/ε^2)Θ(max{m3/k,m2}/ε2) in Frobenius norm on all states and in trace distance on every class at a fixed distance from the pure boundary. The gain 1/k1/k1/k (k≤mk\le mk≤m) away from the pure boundary, against 1/k1/\sqrt k1/k​ on cold number-conserving states, is therefore attained. For bosonic Gaussian states with bounded covariance, any displacement and squeezing, and occupations n1≤⋯≤nmn_1\le\dots\le n_mn1​≤⋯≤nm​, O((m2+r3+∑i,j>r1/(ni+nj))/ε2)O((m^2+r^3+\sum_{i,j>r}1/(n_i+n_j))/ε^2)O((m2+r3+∑i,j>r​1/(ni​+nj​))/ε2) single-copy measurements suffice, rrr the largest index with r nr≤2r\,n_r\le2rnr​≤2; this is the minimax rate on dyadic-interval classes, with no spectral gap or cold-mode count assumed, and holds with no covariance bound for displaced passive states. With no bound on energy or squeezing, non-Gaussian measurements learn centred one-mode states, mixed included, from O(ε−2)O(ε^{-2})O(ε−2) and centred pure mmm-mode states from O(m2/ε2)O(m^2/ε^2)O(m2/ε2) single copies, free of the log⁡log⁡E\log\log EloglogE term of Gaussian measurements, and mmm-mode states from O(m3/ε2)O(m^3/ε^2)O(m3/ε2) copies, entangled only in a first round on blocks of 4m+64m+64m+6.
Unlike in finite dimensions, quantum information in continuous-variable systems has the peculiar feature that without imposing physical constraints, the sample complexity of state tomography can be unbounded. Remarkably, this is even the case for state-of-the-art protocols for learning Gaussian states, which have finite-dimensional descriptions: the best known rates scale with log⁡log⁡E\log \log EloglogE, where EEE is the energy of the system. We prove this is not an artifact of existing analyses, but a fundamental limitation of the measurements used. We show: (1) Any protocol that uses Gaussian measurements, even entangled or adaptively chosen ones, must incur a log⁡log⁡E\log \log EloglogE dependence. This answers an open question posed by a number of previous works. (2) There is a smooth tradeoff between the number of rounds of adaptivity and the energy dependence, and we give a matching protocol achieving this interpolated rate. (3) With highly entangled, non-Gaussian measurements, one can learn nnn-mode pure Gaussian states with O(n2/ε2)O(n^2 / ε^2)O(n2/ε2) samples, independent of EEE. This answers an open question posed by Chen et al. (4) A simple protocol based on the single-copy canonical phase POVM of Holevo and Helstrom learns single-mode pure Gaussian states with O(1/ε2)O(1/ε^2)O(1/ε2) samples, again independent of EEE. Our results clarify the role of energy in bosonic state tomography and shed new light on the intriguing interplay between adaptivity, entanglement, and magic in quantum learning.