Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2611.03984

The Impact of Internal Electric Fields on Accurate Diamond Magnetometry

Jack Faller, Daphne Freda Gavras, Andrew Lowther, Romain Ruhlmann, Lilian Childress

quant-phSubmitted Nov 2, 2026• Announced Nov 4, 2026
arXivHTMLPDF

Abstract

Nitrogen-vacancy (NV) center spin ensembles are a promising platform for accurate vector magnetometry, as they offer measurements referenced to a spin Hamiltonian in an anisotropic crystal with native vector sensing capabilities. However, charged dopants within the diamond produce random internal electric fields (RIEFs) that shift NV spin-transition frequencies, and their impact on the accuracy of NV magnetometry has not been investigated. Here, we characterize RIEFs' effect on NV spin-transition spectra and propose an analytical fitting function to improve accuracy in their presence. We build a Monte Carlo RIEF model that reproduces the asymmetric lineshapes observed in experimental optically detected magnetic resonance (ODMR) spectra, and use it as a testbed to quantify RIEF-induced errors by simulating ODMR spectra including RIEFs and comparing reconstructed magnetic fields to the known model input. With standard analysis approaches, we observe systematic errors exceeding the g-factor uncertainty in fields below $\sim$ 5 mT, while the proposed fitting function reduces the error by nearly an order of magnitude. Our results demonstrate that RIEFs can play a significant role in the systematic error budget for NV magnetometry, and offer a path towards improved accuracy in NV quantum sensing.

AI Summary

This paper asks how random internal electric fields (RIEFs) from charged dopants bias absolute magnetic-field estimates in NV-ensemble magnetometry, beyond their established effect on zero-field sensitivity. A Monte Carlo model assigns electrons to randomly placed NV centers from nearby nitrogen donors, computes local electric fields, and generates spin-transition spectra with magnetic and microwave broadening. It reproduces asymmetric features in experimental finite-bias ODMR spectra that symmetric Voigt profiles do not capture. Systematic errors are quantified by reconstructing known input fields from simulated spectra. For representative concentrations $[\mathrm{NV}^-]=2.7$ ppm and $[\mathrm{N}]=8.5$ ppm, with $T_2^*=1.24\,\mu\mathrm{s}$, conventional peak or Voigt-based estimates show errors exceeding $1\,\mu\mathrm{T}$ at few-mT axial fields. The errors decrease approximately as $B_z^{-1/2}$ over the simulated range, rather than the naively expected $B_z^{-1}$. An analytical asymmetric fitting function, derived using approximately Cauchy-distributed electric-field components, reduces axial-field errors by roughly an order of magnitude. Four-orientation vector reconstruction shows errors up to approximately $5\,\mu\mathrm{T}$ near a 1 mT bias; the fitting advantage diminishes at larger fields. Microwave broadening also shifts inferred fields. The accuracy improvements are simulation-based, not demonstrated against an experimental reference field. The charge model assumes homogeneous dopant distributions and dielectric screening and neglects optical charge dynamics. Most calculations omit nonsecular hyperfine interactions, and the analytical fit assumes an axial field and approximate field distributions. Strain, mosaicity, and other solid-state effects remain outside the modeled accuracy budget.

No sign of AI-generated textAI use disclosedStrong assumptions
An illustration of the Monte Carlo NV$^-$-N$^+$ pair model (generated with code from Claude Sonnet 4.6).

Error found: The abstract leaves the nearly order-of-magnitude fitting improvement unqualified, whereas the body establishes that magnitude for aligned single-axis simulations and reports a field-dependent advantage for vector reconstruction that disappears around 8 mT.

Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.

Comments
14 pages, 8 figures

Related papers

Limits of absolute vector magnetometry with nitrogen-vacancy centers in diamond

Dennis Lönard, Isabel Cardoso Barbosa, Stefan Johansson +2 more

The nitrogen-vacancy (NV) center in diamond has become a widely used platform for quantum sensing. The four NV axes in monocrystalline diamond specifically allow for vector magnetometry, with magnetic-field sensitivities reaching down to fT / Hz . The current literature primarily focuses on improving the precision of NV-based magnetometers. Here, we study the experimental accuracy of determining the magnetic field from measured spin-resonance frequencies via solving the NV Hamiltonian. We derive exact, analytical, and fast-to-compute formulas for calculating resonance frequencies from a known magnetic-field vector, and vice versa (formulas for calculating the magnetic-field vector from measured resonance frequencies). Additionally, the accuracy of often-used approximations is assessed. Finally, we promote using the Voigt profile as a fit model to determine the linewidth of measured resonances accurately. An open-source Python package accompanies our analysis.

arXiv:2504.20750•Physical Review Research•Dec 5, 2025•11 citations

Accurate magnetic field estimation in fiber-coupled nanodiamond NV ensembles using model-assisted regression

Jian Gao, Doudou Zheng, chenchen tang +12 more

Fiber-coupled ensembles of nanodiamonds containing nitrogen-vacancy (NV) centers are widely used for microscopic magnetic field measurements. However, the random distribution of NV crystal axes in nanodiamond ensembles causes resonance frequencies from differently oriented NV centers to overlap in the ODMR spectrum, distorting the spectral line shape and breaking the linear mapping between frequency shift and magnetic field. As a result, conventional magnetic field measurements based on Lorentzian fitting suffer from significant systematic errors. Here, we establish a fiber-nanodiamond ensemble model to analyze the impact of random NV orientations on the ODMR linear response and define an effective ensemble-averaged linear response coefficient K . Fisher information analysis identifies an information-optimal intrinsic magnetic field of approximately 640 µT, at which the ensemble response can be reliably approximated as linear in its vicinity. Building on this condition, we propose a model-assisted regression scheme, in which the physical fiber-nanodiamond ensemble model defines the optimal operating condition and the associated linear frequency-field scaling, while intrinsic-field-guided Gaussian regression (IFGGR) extracts magnetic-field-induced frequency shifts from distorted ensemble ODMR spectra, enabling accurate magnetic field estimation via the response coefficient K . Under identical acquisition conditions, the proposed method reduces the RMSE from 37.21 µT to 8.99 µT and significantly suppresses systematic bias, while achieving an absolute sensitivity approaching the shot-noise limit at optimal averaging time. The relative slope error reduction (≈15.6-fold) further confirms improved local linearity near the optimal operating point.

Optics Express•Feb 27, 2026•13 citations

Imaging the Local Charge Environment of Nitrogen-Vacancy Centers in Diamond

Thomas Mittiga, Satcher Hsieh, Chong Zu +8 more

Characterizing the local internal environment surrounding solid-state spin defects is crucial to harnessing them as nanoscale sensors of external fields. This is especially germane to the case of defect ensembles which can exhibit a complex interplay between interactions, internal fields, and lattice strain. Working with the nitrogen-vacancy (NV) center in diamond, we demonstrate that local electric fields dominate the magnetic resonance behavior of NV ensembles at a low magnetic field. We introduce a simple microscopic model that quantitatively captures the observed spectra for samples with NV concentrations spanning more than two orders of magnitude. Motivated by this understanding, we propose and implement a novel method for the nanoscale localization of individual charges within the diamond lattice; our approach relies upon the fact that the charge induces a NV dark state which depends on the electric field orientation.

arXiv:1809.01668•Physical Review Letters•Dec 12, 2018•169 citations

QDsiM: A Noise-Aware Simulation Toolkit for Quantum Diamond Microscope

Satyam Pandey, Abhimanyu Magapu, Prabhat Anand +2 more

The nitrogen-vacancy (NV) center in diamond is a leading solid-state platform for room-temperature quantum magnetometry owing to its long spin coherence times, optical spin initialization and readout, and high sensitivity to magnetic, electric, and thermal perturbations. As NV-based optically detected magnetic resonance (ODMR) systems transition from controlled laboratory environments toward portable and field-deployable sensors, a detailed understanding of realistic noise sources and experimental imperfections becomes essential for optimizing performance and sensitivity. In this work, we present a comprehensive simulation framework, i.e., a digital twin, for continuous-wave wide-field ODMR in NV-center ensembles. The model is built upon a physically consistent seven-level description of the NV center and incorporates a broad range of experimentally relevant noise and imperfection mechanisms as modular, parameterized components. These include laser and microwave amplitude fluctuations, microwave phase noise, uncertainty in the NV gyromagnetic ratio, spin dephasing, temperature-induced shifts of the ground-state zero-field splitting, surface-induced magnetic field perturbations, and photon shot noise. Power broadening and contrast degradation arising from optical and microwave driving are captured self-consistently through linewidth calculations. Also, the spatial inhomogeneity is modeled via a Gaussian laser intensity profile across the sensing region...

quant-pharXiv:2601.11649•Jan 16, 2026

Electric and magnetic sensing with NV ensembles in diamonds

Sarvagya Sharma, Chris Hovde, Fahad S. Alghannam +1 more

We report measurements of optically detected magnetic resonance spectra of ensembles of nitrogen-vacancy (NV-) centers in diamonds in the presence of electromagnetic fields. To reduce inhomogeneous broadening, the spectra are acquired from a region of 20 cubic microns in a CVD(Chemical Vapor Deposition) diamond through a confocal microscope. The Stark shift from transverse electric fields is enhanced at avoided crossings between the hyperfine levels that arise from interaction with 14N(I = 1) nuclei in the diamond lattice. As expected from previous reports, the Stark shift of the spectral lines is stronger when there is no magnetic field along the NV axis. The shift is also strong, but for different transitions, at a field of about 100 uT.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jan 27, 2017•2 citations

Exploratory Study on Electric Field Measurement Utilizing Nitrogen-Vacancy Centers in Diamond

Jing Liu, Haoliang Hu, Han Wang +1 more

Diamond nitrogen-vacancy (NV) centers are widely studied for quantum sensing in multiple physical fields due to their long coherence time and room-temperature optical readout. However, accurately decoupling and extracting signals for individual fields from fluorescence remains a major challenge. In this work, by establishing the spatial configuration between the four axes of the NV center and the directions of the externally applied electric and magnetic fields, the resonance frequency shifts of two pairs in the ODMR spectrum are exclusively induced by the electric field, whereas those of the other two pairs are exclusively induced by the magnetic field. Consequently, effective decoupling and readout of the electric field signal are realized. The experiments measure electric fields from 0 to 20 kV/cm in the diamond sample, revealing a linear relationship between the resonance frequency shift and the applied electric field, with coefficients 0.1713MHz/(kV/cm) and 0.1660MHz/(kV/cm) matching the NV center’s linear Stark effect, laying the foundation for subsequent research on electric field measurement.

•Nov 21, 2025•0 citations
Nitrogen-vacancy (NV) center spin ensembles are a promising platform for accurate vector magnetometry, as they offer measurements referenced to a spin Hamiltonian in an anisotropic crystal with native vector sensing capabilities. However, charged dopants within the diamond produce random internal electric fields (RIEFs) that shift NV spin-transition frequencies, and their impact on the accuracy of NV magnetometry has not been investigated. Here, we characterize RIEFs' effect on NV spin-transition spectra and propose an analytical fitting function to improve accuracy in their presence. We build a Monte Carlo RIEF model that reproduces the asymmetric lineshapes observed in experimental optically detected magnetic resonance (ODMR) spectra, and use it as a testbed to quantify RIEF-induced errors by simulating ODMR spectra including RIEFs and comparing reconstructed magnetic fields to the known model input. With standard analysis approaches, we observe systematic errors exceeding the g-factor uncertainty in fields below ∼\sim∼ 5 mT, while the proposed fitting function reduces the error by nearly an order of magnitude. Our results demonstrate that RIEFs can play a significant role in the systematic error budget for NV magnetometry, and offer a path towards improved accuracy in NV quantum sensing.
This paper asks how random internal electric fields (RIEFs) from charged dopants bias absolute magnetic-field estimates in NV-ensemble magnetometry, beyond their established effect on zero-field sensitivity. A Monte Carlo model assigns electrons to randomly placed NV centers from nearby nitrogen donors, computes local electric fields, and generates spin-transition spectra with magnetic and microwave broadening. It reproduces asymmetric features in experimental finite-bias ODMR spectra that symmetric Voigt profiles do not capture.
Systematic errors are quantified by reconstructing known input fields from simulated spectra. For representative concentrations [NV−]=2.7[\mathrm{NV}^-]=2.7[NV−]=2.7 ppm and [N]=8.5[\mathrm{N}]=8.5[N]=8.5 ppm, with T2∗=1.24 μsT_2^*=1.24\,\mu\mathrm{s}T2∗​=1.24μs, conventional peak or Voigt-based estimates show errors exceeding 1 μT1\,\mu\mathrm{T}1μT at few-mT axial fields. The errors decrease approximately as Bz−1/2B_z^{-1/2}Bz−1/2​ over the simulated range, rather than the naively expected Bz−1B_z^{-1}Bz−1​. An analytical asymmetric fitting function, derived using approximately Cauchy-distributed electric-field components, reduces axial-field errors by roughly an order of magnitude. Four-orientation vector reconstruction shows errors up to approximately 5 μT5\,\mu\mathrm{T}5μT near a 1 mT bias; the fitting advantage diminishes at larger fields. Microwave broadening also shifts inferred fields.
The accuracy improvements are simulation-based, not demonstrated against an experimental reference field. The charge model assumes homogeneous dopant distributions and dielectric screening and neglects optical charge dynamics. Most calculations omit nonsecular hyperfine interactions, and the analytical fit assumes an axial field and approximate field distributions. Strain, mosaicity, and other solid-state effects remain outside the modeled accuracy budget.
The nitrogen-vacancy (NV) center in diamond has become a widely used platform for quantum sensing. The four NV axes in monocrystalline diamond specifically allow for vector magnetometry, with magnetic-field sensitivities reaching down to fT / Hz . The current literature primarily focuses on improving the precision of NV-based magnetometers. Here, we study the experimental accuracy of determining the magnetic field from measured spin-resonance frequencies via solving the NV Hamiltonian. We derive exact, analytical, and fast-to-compute formulas for calculating resonance frequencies from a known magnetic-field vector, and vice versa (formulas for calculating the magnetic-field vector from measured resonance frequencies). Additionally, the accuracy of often-used approximations is assessed. Finally, we promote using the Voigt profile as a fit model to determine the linewidth of measured resonances accurately. An open-source Python package accompanies our analysis.
Fiber-coupled ensembles of nanodiamonds containing nitrogen-vacancy (NV) centers are widely used for microscopic magnetic field measurements. However, the random distribution of NV crystal axes in nanodiamond ensembles causes resonance frequencies from differently oriented NV centers to overlap in the ODMR spectrum, distorting the spectral line shape and breaking the linear mapping between frequency shift and magnetic field. As a result, conventional magnetic field measurements based on Lorentzian fitting suffer from significant systematic errors. Here, we establish a fiber-nanodiamond ensemble model to analyze the impact of random NV orientations on the ODMR linear response and define an effective ensemble-averaged linear response coefficient K . Fisher information analysis identifies an information-optimal intrinsic magnetic field of approximately 640 µT, at which the ensemble response can be reliably approximated as linear in its vicinity. Building on this condition, we propose a model-assisted regression scheme, in which the physical fiber-nanodiamond ensemble model defines the optimal operating condition and the associated linear frequency-field scaling, while intrinsic-field-guided Gaussian regression (IFGGR) extracts magnetic-field-induced frequency shifts from distorted ensemble ODMR spectra, enabling accurate magnetic field estimation via the response coefficient K . Under identical acquisition conditions, the proposed method reduces the RMSE from 37.21 µT to 8.99 µT and significantly suppresses systematic bias, while achieving an absolute sensitivity approaching the shot-noise limit at optimal averaging time. The relative slope error reduction (≈15.6-fold) further confirms improved local linearity near the optimal operating point.
Characterizing the local internal environment surrounding solid-state spin defects is crucial to harnessing them as nanoscale sensors of external fields. This is especially germane to the case of defect ensembles which can exhibit a complex interplay between interactions, internal fields, and lattice strain. Working with the nitrogen-vacancy (NV) center in diamond, we demonstrate that local electric fields dominate the magnetic resonance behavior of NV ensembles at a low magnetic field. We introduce a simple microscopic model that quantitatively captures the observed spectra for samples with NV concentrations spanning more than two orders of magnitude. Motivated by this understanding, we propose and implement a novel method for the nanoscale localization of individual charges within the diamond lattice; our approach relies upon the fact that the charge induces a NV dark state which depends on the electric field orientation.
The nitrogen-vacancy (NV) center in diamond is a leading solid-state platform for room-temperature quantum magnetometry owing to its long spin coherence times, optical spin initialization and readout, and high sensitivity to magnetic, electric, and thermal perturbations. As NV-based optically detected magnetic resonance (ODMR) systems transition from controlled laboratory environments toward portable and field-deployable sensors, a detailed understanding of realistic noise sources and experimental imperfections becomes essential for optimizing performance and sensitivity. In this work, we present a comprehensive simulation framework, i.e., a digital twin, for continuous-wave wide-field ODMR in NV-center ensembles. The model is built upon a physically consistent seven-level description of the NV center and incorporates a broad range of experimentally relevant noise and imperfection mechanisms as modular, parameterized components. These include laser and microwave amplitude fluctuations, microwave phase noise, uncertainty in the NV gyromagnetic ratio, spin dephasing, temperature-induced shifts of the ground-state zero-field splitting, surface-induced magnetic field perturbations, and photon shot noise. Power broadening and contrast degradation arising from optical and microwave driving are captured self-consistently through linewidth calculations. Also, the spatial inhomogeneity is modeled via a Gaussian laser intensity profile across the sensing region...
We report measurements of optically detected magnetic resonance spectra of ensembles of nitrogen-vacancy (NV-) centers in diamonds in the presence of electromagnetic fields. To reduce inhomogeneous broadening, the spectra are acquired from a region of 20 cubic microns in a CVD(Chemical Vapor Deposition) diamond through a confocal microscope. The Stark shift from transverse electric fields is enhanced at avoided crossings between the hyperfine levels that arise from interaction with 14N(I = 1) nuclei in the diamond lattice. As expected from previous reports, the Stark shift of the spectral lines is stronger when there is no magnetic field along the NV axis. The shift is also strong, but for different transitions, at a field of about 100 uT.
Diamond nitrogen-vacancy (NV) centers are widely studied for quantum sensing in multiple physical fields due to their long coherence time and room-temperature optical readout. However, accurately decoupling and extracting signals for individual fields from fluorescence remains a major challenge. In this work, by establishing the spatial configuration between the four axes of the NV center and the directions of the externally applied electric and magnetic fields, the resonance frequency shifts of two pairs in the ODMR spectrum are exclusively induced by the electric field, whereas those of the other two pairs are exclusively induced by the magnetic field. Consequently, effective decoupling and readout of the electric field signal are realized. The experiments measure electric fields from 0 to 20 kV/cm in the diamond sample, revealing a linear relationship between the resonance frequency shift and the applied electric field, with coefficients 0.1713MHz/(kV/cm) and 0.1660MHz/(kV/cm) matching the NV center’s linear Stark effect, laying the foundation for subsequent research on electric field measurement.