arXiv:2611.00934
Single-Mode Squeezing Using Degenerate Four-Wave Mixing in a Dual-Pump TWPA
Anna Levochkina, Kirill Petrovnin, Iiro Harju, Jiaming Wang, Gheorghe Sorin Paraoanu
Abstract
Single-mode squeezing of the electromagnetic vacuum is a key resource for mode-selective noise reduction in quantum measurements. At microwave frequencies, single-mode squeezing is typically obtained by using Josephson and Traveling-Wave Parametric Amplifiers designed for three-wave mixing operation. In single-pump degenerate four-wave mixing, the coincidence of pump, signal, and idler frequencies complicates separation of the squeezed field from the strong pump. A dual-pump configuration enables degenerate operation while keeping both pumps spectrally separated from the squeezed mode. Here, we demonstrate single-mode squeezing in a flux-tunable, dual-pump Traveling-Wave Parametric Amplifier, employing reversed-Kerr phase matching. By independently calibrating the single-pump gains, we find that the strongest squeezing occurs along approximately balanced-gain trajectories, while the optimal squeezing does not necessarily correspond to the highest dual-pump gain. At flux biases $Φ_\mathrm{ext}/Φ_0 = 0.0$ and $0.5$, the minimum quadrature noise levels reach $-2.48 \pm 0.18~\mathrm{dB}$ and $-1.62 \pm 0.20~\mathrm{dB}$ relative to vacuum, respectively. These results establish the proposed architecture as a platform for single-mode squeezing in microwave continuous-variable quantum technologies.
AI Summary
Can dual-pump degenerate four-wave mixing produce single-mode microwave squeezing in a TWPA using reversed-Kerr phase matching rather than engineered spectral gaps? This paper tests a flux-tunable transmission line containing 700 SNAILs, driven at $3.8$ and $6.5\,\mathrm{GHz}$ to squeeze the mode at $5.15\,\mathrm{GHz}$. A reduced coupled-mode model examines phase mismatch, circuit simulations compare single-pump gain profiles, and independent single-pump gain calibrations guide experimental pump-power sweeps. Quadrature measurements alternate pump-ON and pump-OFF intervals, with Johnson–Nyquist thermometry calibrating detection-chain gain and noise. The minimum reconstructed quadrature variances relative to vacuum are $-2.48\pm0.18\,\mathrm{dB}$ at $\Phi_{\mathrm{ext}}/\Phi_0=0$ and $-1.62\pm0.20\,\mathrm{dB}$ at $0.5$, occurring at approximately $3$ and $5.5\,\mathrm{dB}$ dual-pump gain, respectively. Calibration uncertainty dominates the quoted errors. The strongest squeezing occurs near approximately balanced single-pump-gain trajectories, but squeezing subsequently deteriorates even as dual-pump gain increases and nominal balance is maintained. Inferred Gaussian-state purities at the squeezing optima are $0.668\pm0.028$ and $0.727\pm0.039$, respectively. The measurements do not identify the cause of high-power deterioration or isolate phase matching from other flux-dependent effects. Higher-order nonlinearities, residual three-wave mixing, internal loss, and additional mixing channels remain possible contributors. The reduced model does not quantitatively reproduce the experiment; its constant-coupling, perfectly phase-matched loss benchmark does not produce the observed upturn. Reconstruction assumes a vacuum pump-OFF reference and unchanged detection-chain gain and added noise between acquisitions, without correcting for assumed internal TWPA loss.
Error found: Appendix C calibrates the detection gain using classical Johnson–Nyquist noise without specifying the temperature fitting range or justifying neglect of quantum corrections at 5.15 GHz, leaving a systematic uncertainty in the reported squeezing values unquantified.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.